Techsem MDC300-36-415F3, Dual Diode Module, 300 Amp, 3600V, 62mm Package
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
Planar passivated chips
International standard package
3600V Isolation
62mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
Techsem Part Number
MDC300-36-413F3D
Vrrm
3600V
Diode Configuration
Dual Diode Module
IF(av) @ 100 Deg C
300 Amp
Package Size
W:50mm L:115mm D:52mm
Itsm
9.1 kA
VF(to)
0.75V
Tj(max)
150°C
rF
0.56mΩ
Terminals
M8 Bolt
Hole Centres
80mm x 38mm (M6)
Gate Terminals
N/A
R th(j-c)
0.13°C/W
R th(c-h)
0.04°C/W
Weight
800g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
6
Certification
ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MDD312-16N1 for alternative IXYS solder contact alternative
FTH12053ZA4 + HS212F, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH12053ZA4 + HS212F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS103DR
Product Datasheet
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FTH2553ZA4 + HS212, Solid State Relay, and Heatsink Assembly, 3 Phase 90-280VAC Control, 20 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator, with IP20 Cover
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Fastron Part Number
FTH2553ZA4 + HS212
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 20 Amp (rms) per Phase
Surge Capability
350 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
HS103DR
D53TP Series
3 Phase SSR and Heatsink Mounted
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
E62.G85-402G10, 4uF, 50x62mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 1350VAC/2250VDC
Characteristics and utility
4uF Voltage: 1350VAC/2250VDC
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M12 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.G85-402G10
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø50x85mm
Mounting
M12 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
1350VAC/2250VDC
Operating Temperature Range
-40 to 85 °C
Capacitance
4uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
M6 x 12 studs
Unit Weight
0.2kg
Factory Pack Quantity
21 (MOQ = 105)
Datasheet
Product Datasheet
Iskra Systemi KNK3053 15.5KVAR 480V 50HZ, Power Factor Correction Capacitor, 3 Phase, 75 x 245mm Dry Type, 3 x 71.4uF, Possible Replacement to Frako LKT 15.5-480-DPS (70 x 225mm), or LKT 15.5-480-DP (70x265mm)
Characteristics and utility
Drop In replacement for FRAKO - LKT15.5-480-DPS
15.5kVar @ 480V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - Feed through terminals
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Iskra Part Number
KNK3053 15.5KVAR 480V 50HZ
Technology
Dry Type, Low Loss, Self Healing
Dimensions
75 x 245mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
480V @ 50Hz
Kvar
15.5 Kvar
Capacitance
3 x 71.4uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 18.6 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Double sided Filter Type Terminal
Unit Weight
2.9kg
Factory Pack Quantity
25
Datasheet
Iskra PCF Catalogue
Capacitor Datasheet
Comparison to Frako LKT 15.5 480 DPS
PFC Capacitor Comparison Chart
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Hot Spot Testing
25kvar Specification Sheet
40kvar Specification Sheet
Fastron Electronics GT-DVO(-75mV,+75mV)D1, Signal Conditioner/Isolator/Voltage Transducer, +75mV to -75rmVDC input, 22-60VAC/DC aux, 4-20mA output
Program control, converter function are standard features
5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
9-step pattern (for SV and time) is a standard feature
UL/CSA Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
Specification
Fastron Electronics Part Number
GT-DVO(-75mV,+75mV)D1
Control Output
4 - 20mA
Input
+75mVDC to - 75mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo MOD2 A230 SHT, Shunt Trip Module For 3 Pole MOD2 MCCB Disconnect Switch
Rotary Extended Handle for Miniature Circuit Breakers is used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
Rotary handle mounts directly on MCCB with screws (included) without removal of midcover
Clear ON/OFF/TRIP
SuDirect access to push to trip button with rotary handle mounted
Datasheet
Product Datasheet
Semikron SKD160/18, 3 Phase Diode Rectifier Bridge, 205Amp, 1600V, Replaces Powersem PSD162T/16, and IXYS VUO160-16 N07
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Semikron Part Number
SKD160/18
AC Line voltage
1800V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
160 Amp
Package Size
W:94mm L:54mm D:30mm
Itsm
1800 A
VF(to)
0.8V
Tj(max)
150°C
Terminals
M6 (5Nm)
Hole Centres
80mm (M6)
Gate Terminals
N/A
Weight
270g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Semikron Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See PSD192T/16 for higher rated equivalent
Semikron SKD210/18, 3 Phase Diode Rectifier Bridge, 207Amp, 1600V, Replaces Powersem PSD162T/16, and IXYS VUO160-16 N07
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Semikron Part Number
SKD210/18
AC Line voltage
600V
Device Configuration
Three Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
205 Amp
Package Size
W:94mm L:54mm D:30mm
Itsm
2000 A
VF(to)
0.85V
Tj(max)
150°C
Terminals
M6 (5Nm)
Hole Centres
80mm (M6)
Gate Terminals
N/A
Weight
270g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Semikron Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See PSD192T/16 for higher rated equivalent
DC-0-50-420-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Unipolar output, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-50 Amp DC, 4-20 mA Unipolar Output
Other measurement ranges available on request
Features
⌀20mm Aperture
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DC-0-50-420-1.0
Technology
DC Hall Current Sensor with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-50 Amp
Response Time
< 1uS
Output
Unipolar 4-20mA
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Terminals
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet