HAIS 400-P O/L Hall Effect Current Sensor, 400 Amp, vref 0-5V Output, PCB Mount, 15x8mm sqr, X = 1%
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 50 to 600 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Specification
LEM Part Number
HAIS 400-P
Technology
Open Loop Hall Effect
Aperture
15 x 8mm Square
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
400 Amp
Overload Capability
+/- 600 Amp
Output
2.5 Vref
Isolation
2.5kV
Bandwidth
DC-50 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
PCB
Unit Weight
30g
Factory Pack Quantity
10
Datasheet
Product Datasheet
LEM APR 400 B420L, Split Core AC Current Sensor, selectable 200, 300, 400 Amp, True RMS 4-20mA output, Infinite Overload Capability
Compact and versatile Split Core AC current sensor, selectable 200, 300, 400 Amp True RMS 4-20mA output
Features
Split Core
True RMS output
4-20mA current output
Busbar, or Din Rail
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 18.5mm x 18.5mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
APR 400 B420L
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC @ 30mA
Nominal Current (RMS + DC)
200,300,400 Amp Selectable
Overload
Infinite
Output
4-20mA True RMS
Isolation
5kV (AC, 50Hz, 1 min)
Bandwidth
30-2000Hz
Mounting Style
Din Rail mount or Busbar mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Spring Terminal Block (Female Included)
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM FRS 1000-SBI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coresless Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 1000-SBI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/-3000 Amp
Overload Rating
N/A
Output
4-20mA Bipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
LEM APR 100 B420L, Split Core AC Current Sensor, selectable 50, 75, 100 Amp, True RMS 4-20mA output, Infinite Overload Capability
Compact and versatile Split Core AC current sensor, selectable 50, 75, 100 Amp True RMS 4-20mA output
Features
Split Core
True RMS output
4-20mA current output
Busbar, or Din Rail mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 18.5mm x 18.5mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
APR 100 B420L
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC @ 30mA
Nominal Current (RMS + DC)
50,75,100 Amp Selectable
Overload
Infinite
Output
4-20mA True RMS
Isolation
5kV (AC, 50Hz, 1 min)
Bandwidth
30-2000Hz
Mounting Style
Din Rail mount or Busbar mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Spring Terminal Block (Female Included)
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM DVL 2000 Series Closed Loop AC/DC Digital Voltage Transducer 2000V Input, 50mA output, +/- 15V…24VDC, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 2000
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 2000V
Measurement Range
+/- 3000V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
HAL 50-S O/L Hall Effect Current Sensor, 50 Amp, +/-4V Output, 15x20mm sqr, X = 1%
Features
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Advantages
Wide dynamic range, 50 to 600 A in one package.
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Specification
LEM Part Number
HAL 50-S
Technology
Open Loop Hall Effect
Aperture
20 x 15mm Square
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
50 Amp
Overload Capability
30,000 Amp
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-50 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-040A
Unit Weight
75g
Factory Pack Quantity
10
Datasheet
Product Datasheet
BH-100-1-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Iskra Doo MFR 10 161-346VAC, Frequency Monitoring Relay
MFR 10 Series serves to monitor AC frequencies from 40 to 70Hz, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Â
Galvanically separates monitored circuit
Wide range supply 161-346VAC
Maximum measurement voltage 346VAC
Output contact: 1x changeover/SPDT 8 A Clamp terminals 1-phase, 1-MODULE, DIN rail mounting
Applications :
Generators
Frequency Converters
Specification
Iskra Doo Part Number
MFR 10 161-346VAC
Voltage Range
161 - 346 VAC (40 - 70 Hz)
Operating Range
-15 %; +10 %
Measurement Range
40 - 70 Hz
Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/°C
Peak Overload (10s)
N/A
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
Â
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
8 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Â
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet
Fastron Electronics FAT300D10, AC Current Transducer, 300Amp Measurement, 24mm Split Core, 0-10V Average RMS Output, Accuracy = 1%, 500mm Cable Length
Features
Quick Release 24mm Split Core System
Cale Mount
0-10V Output
24VDC Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
FAT300D10
Technology
24mm Split Core AC Current Transformer
Ratio
300/0-10V
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0-10V (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
LEM HOP 500-SB/SP1 O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 8kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 200 to 600 A in one package.
Up to 900 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 500-SB/SP1
Technology
Open Loop Hall Effect
Aperture
104 x 40mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/-1000 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
FP150125P/80mA, 1500/80mA Split Core CT, Class 0.5, 7.5VA, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Electronics Part Number
FP150125P/80mA
Technology
Split Core AC Clip On Current Transformer
Ratio
1500/80mA
Aperture Size
85 x 120mm
VA Rating
7.5VA
Accuracy Class
Class 0.5
Output
80mA Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
1500Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Installation Guide
Â
LEM FRS 1500-SUI, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 1500-SUI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
1500 Amp
Measurement Range
+/-4500 Amp
Overload Rating
N/A
Output
4-20mA Unipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â