H-10-2-24, Split Core Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20mA Unipolar Output
Features
⌀31mm Aperture
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
H-10-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-10 Amp
Response Time
< 200mS
Output
Unipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Northern Design XD-V5-2, AC Current Transducer, Average RMS, Ipn = Selectable 15,30,45,60,75,100 Amp, 0-5V Average RMS output, Self Powered
Features
Ipn = Selectable 15,30,45,60,75,100 Amp
Average RMS Output
0-5V Output
Din Rail Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀ 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Earth Leakage Measurement
Motor Control
Actuators
Lamp Failure
Specification
Northern Design Part Number
XD-V5-2
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
Selectable 15,30,45,60,75,100 Amp
Output
0-5V Average RMS
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
Class 1
Termination Style
Screw
Unit Weight
180g
Factory Pack Qty
6
Â
Datasheet
Product Brochure
Product Manual
Â
LEM HOP 2000-SB O/L Split Core Hall Effect Current Sensor, 2000 Amp, +/-4V Output, 40 x 104mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 10kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 500 to 2500 A in one package.
Up to 3000 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 2000-SB
Technology
Open Loop Hall Effect
Aperture
104 x 40mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/-3000 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
HLP1, Indicator, 48x24mm, Self Powered, 4-20mA Input, 4 Digit, -9999 to +9999 Display Range
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s or selectable response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 45.5 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
HLP1
Control Output 1 (Heat)
N/A
Control Output 2 (Cool)
N/A
Input
4-20mA Current Loop
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
Self Powered
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
HLP1 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
H-100-2-24, Split Core Hall Effect DC Current Transducer, 0-100 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20mA Unipolar Output
Features
⌀31mm Aperture
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
H-100-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-100 Amp
Response Time
< 200mS
Output
Unipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
Fastron Electronics FAT200D10, AC Current Transducer, 200Amp Measurement, 24mm Split Core, 0-10V Average RMS Output, Accuracy = 1%, 500mm Cable Length
Features
Quick Release 24mm Split Core System
Cale Mount
0-10V Output
24VDC Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
FAT200D10
Technology
24mm Split Core AC Current Transformer
Ratio
200/0-10V
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0-10V (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
200Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics FAT250D10, AC Current Transducer, 250Amp Measurement, 36mm Split Core, 0-10V Average RMS Output, Accuracy = 1%, 500mm Cable Length
Features
Quick Release 36mm Split Core System
Cale Mount
0-10V Output
24VDC Aux
Rated System Voltage 0.60/2.5kV
0.5M Flying Leads
Applications
Control Systems
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Fastron Part Number
FAT250D10
Technology
36mm Split Core AC Current Transformer
Ratio
250/0-10V
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0-10V (+20%)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw Terminals
Unit Weight
250g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
ACSP-50-010, Self Powered Split Core AC Current Transducer, 50 Amp AC, 0-10V Average RMS Output, 31mm aperture
Compact and versatile Self Powered Split Core AC Current Transducer, Comes with 0-10V/0-5V, or 4-20mA Average RMS Analogue Output
Features
⌀31mm Aperture
Split Core
AC Average RMS Measurement
+/-10V analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
ACSP-50-010
Technology
AC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
Self PoweredÂ
Nominal Current (DC)
50 Amp RMS
Response Time
< 200mS
Output
0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Â
Datasheet
Product Datasheet
LEM HTR HTR 100-SB, Open Loop Hall Effect Current Sensor, 100 Amp, +/-4V Output, Split Core 21mm Aperture, X = 2%
Features
Bandwidth DC to 10kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range 50 to 500 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
HTR 100-SB
Technology
Split Core Open Loop Hall Effect
Aperture
ø21mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
100 Amp
Measurement Range
+/-200 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 70°C
Accuracy
2%
Termination Style
Molex 5046-04A/AG
Unit Weight
80g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coresless Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 1000-SUI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/-3000 Amp
Overload Rating
N/A
Output
4-20mA Unipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
LEM FRS 2500-SUI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 2500-SUI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
2500 Amp
Measurement Range
+/-7500 Amp
Overload Rating
N/A
Output
4-20mA Unipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
HAIS 400-P O/L Hall Effect Current Sensor, 400 Amp, vref 0-5V Output, PCB Mount, 15x8mm sqr, X = 1%
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 50 to 600 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Specification
LEM Part Number
HAIS 400-P
Technology
Open Loop Hall Effect
Aperture
15 x 8mm Square
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
400 Amp
Overload Capability
+/- 600 Amp
Output
2.5 Vref
Isolation
2.5kV
Bandwidth
DC-50 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
PCB
Unit Weight
30g
Factory Pack Quantity
10
Datasheet
Product Datasheet