TRIB-22D-G-240, 22mm LED Pushbutton & Indicator GREEN 240VAC, Plastic, IEC60947-5-1
Pushbutton Indicator Switches are a combinations of LED indicator Series and Momentary Pushbutton Switches. LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
1 Pole Momentary
LED Illumination
Rated for 6 Amp @ 240VAC, or 0.3 Amp @ 240VDC
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRIB-22D-R-240
Functions
Momentary
Nominal Voltage
240VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
RED LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Nominal Current Range AC
6 Amp @240VAC
Nominal Current Range DC
0.3 Amp @ 240VDC
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP40, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TA800E-LR240, Red LED Bead Replacements for 240VAC TRIB, TRI Series Indicators
LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TA800E-LR240
Functions
LED Indicator Bulb Replacement
Nominal Voltage
240VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Red LED
Approvals
CE
Weight
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TA800E-LY240, Green LED Bead Replacements for 240VAC TRIB, TRI Series Indicators
LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TA800E-LG240
Functions
LED Indicator Bulb Replacement
Nominal Voltage
240VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Green LED
Approvals
CE
Weight
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Eastron Europe SDM120CTModbus-MID-100mV, DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1/Class B, 100mV CT Connect, w/ 2 x pulse outputs and RS485 Comms, MID Approved. *Best accuracy for low current measurements
100mV CT Connect
1 x Configurable Pule Output (via Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM120CTModbus-MID-100mV
Functions
Single Phase Energy Meter
Supply Voltage
230V L-N, 5 Amp +/-15% < 5VA
Nominal Measurement Range
230V L-L 230V L-N, 45 Amp
Maximum Measurement Range
276V L-L 230V L-N, 45 Amp
Nominal Current Input
100mV Amp CT
Pulse Output
1 x 1000imp/kwh, 1 x Configurable 60/100(default)/200ms
Primary CT Ratio
5,10,20,30,40,50,75,100,125,150,200,250,300,400,600 Amp
Accuracy
Class 1/ Class B (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
24mm x 100mm x 66mm (1 module wide)
Isolation
4kV
RS485
2400-38400 b/s
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 6 Modules
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
User Manual
Modbus Protocol
Setup Video
Modbus Utility
EEM Meter Setting Software Utility
Electronicon 275.398-715401/221602 40KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 136 x 245(+47)mm Gas Filled (This package includes Model#275.396-715401 + Discharge Resistor)
Characteristics and utility
40kVar @ 525V @ 50 Hz / 25kVar @ 400VAC
Three phase capacitor internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.396-715401/221602 40KVAR 525V 50HZ, + 275.105.10120
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
136 x 245(+47)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
40 Kvar
Capacitance
3 x 154uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 72 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal (Feed Through)
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
3.2kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Note we will supply 275.396-715401/221K02 with 275.105-10120 Discharge resistor. These are drop in replacements with 15mm lower height
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Trent H31/180M-F & FCR-400-60R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 60 Amp Per Phase @ 50 Deg C
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
H31/150M-F & FCR-400-60R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
60 Amp (rms) @ 50 Deg C
Surge Capability
500 Amp (peak) 10mS
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
L:220 x W:125 x D:180mm
Unit Weight
4.3kg
Factory Pack Qty
20
Datasheet
FCR-400-60R
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Techsem MT600-16-433F2 (Obsolete), Single Thyristor(SCR) Module, 600 Amp, 1600V
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
International standard package
3600V Isolation
50mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
Techsem Part Number
MT600-16-433F2
Vrrm
1600V
Diode Configuration
Single Diode Module
IF(av) @ 150 Deg C
500 Amp
Package Size
W:50mm L:101mm D:52mm
Itsm
16 kA
VF(to)
0.80V
Tj(max)
125°C
rF
0.28mΩ
Terminals
M8 Bolt
Hole Centres
80mm x 38mm (M6)
Gate Terminals
N/A
R th(j-c)
0.054°C/W
R th(c-h)
0.024°C/W
Weight
765g
Mounting Torque
7 Nm (13 Nm Terminals)
Factory Pack Qty
3
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
Replaces Techsem TZ600N16K or IXYS MCO600-16io1
Fastron Electronics SCT-F16-20-1A, 20/1Amp Measurement, Class 1 Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-20-1A
Technology
Split Core AC Current Transformer
Ratio
20/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
20Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
FP020080P/1A, 200/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FP020080P/1A
Technology
Split Core AC Clip On Current Transformer
Ratio
200/1
Aperture Size
50 x 80mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
1 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Approvals
CE
Unit Weight
1150g
Factory Pack Qty
1
Datasheet
Product Datasheet
Installation Guide
Westcode-IXYS-Littlefuse DMA150E1600NA, Single Diode Module, 1600V, 150Amp, SOT-227B
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Westcode-IXYS-Littlefuse Part Number
DMA150E1600NA
AC Line voltage
533V
Device Configuration
Three Phase Half Wave Diode Rectifier Bridge
DC Output @ 95 Deg C
150 Amp
Package Size
W:38mm L:25mm D:12mm (SOT-227B)
Itsm
800 A
VF(to)
0.82V
Tj(max)
150°C
rF
6.3mΩ
Terminals
M4 (1.5Nm)
Hole Centres
32mm (M4)
Gate Terminals
N/A
R th(j-c)
0.6°C/W
R th(c-h)
0.1°C/W
Weight
30g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
IXYS Headquarters
United States
Datasheet
Product Datasheet
FR28 2.5A-4A, 2.5 - 4 Amp Thermal Overload Relay for FGC1-K Series Mini Contactors
Features
Snap on
2 x NO, 2 x NC 6 Amp Contacts
150 grams
Datasheet
Thermal Relays Datasheet
FR28 5.5A-8A, 5.5 - 8 Amp Thermal Overload Relay for FGC1-K Series Mini Contactors
Features
Snap on
2 x NO, 2 x NC 6 Amp Contacts
150 grams
Datasheet
Thermal Relays Datasheet