Schurter 5500-2063, 2 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
2-stage - high attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2063
Rated Voltage
250V
Rated Current
10A
Filter Stages
2 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
2.5mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2042, 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2042
Rated Voltage
250V
Rated Current
10A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Standard Attenuation
Leakage Current
0.25mA
Mounting
Panel Mount - Case 41
Material
Metal
Termination Style
Screw
Weight
55g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
F922 Series AC Average RMS or DC Current Transducer, 9-36VDC Supply, 0-8 Amp, 4 Output types available
Features
Isolated measurement of AC or DC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC or DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F922-X-XX-XX
Functions
Single Phase AC or DC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
F921-A-XX-XX-XX Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor
Features
Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture
Incorporates an integrated input level display and power supply
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC Average RMS or DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty, Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-DC-XX-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-20000 Amp (Sensor dependant)
Maximum Measurement Range
0-20000 Amp with External Sensor
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
F921 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm
Features
Isolated measurement of AC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-AC-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
LEM HLSR 10-SM/SP33 Series Open Loop AC/DC Hall Effect Sensor
Features
Open loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 400kHz
Single supply + 3.3 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for Surface mount PCB mounting
Factory calibrated.
High bandwidth, very low loss magnetic core
Advantages
Extremely low profile: h = 12mm
Low foot-print
Low offset drift
Over-drivable VREF
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
MPPT
Standards
EN 50178: 1997
UL 508: 2010
IEC 61326-1: 2012
IEC 61010-1: 2010 (safety)
Application Domain
Industrial
Specification
LEM Part Number
HLSR 10-SM/SP33
Technology
Open Loop Hall Effect
Aperture
None
ROHS
Yes
Supply Voltage
3.3 VDC
Load Current (RMS + DC)
10 Amp
Measurement Range
+/-25 Amp
Output
1.65 Vref
Isolation
4.3 kV
Bandwidth
DC-450 kHz
Mounting Style
Surface Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
PCB
Unit Weight
5g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Techsem MFC90-16-223F3, Thyristor Diode Module, 90 Amp, 1600V, 20mm package
Features
Pressure Contact Technology
Package with DCB ceramic
Electrically insulated base plate
Improved temperature and power cycling
Planar passivated chips
Very low forward voltage drop
Very low leakage current
3600V Isolation
Industrial standard package
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
For single and three phase bridge configurations
Field supply for DC motors
Input rectifiers for PWM inverter
Specification
Techsem Part Number
MFC90-16-223F3
Vrrm
1600V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
104 Amp
Package Size
TO-240AA W:20mm L:93mm D:30mm
Itsm
1.8 kA
VF(to)
0.8V
Tj(max)
125°C
rF
3.01mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Trigger Current
100mA
R th(j-c)
0.28°C/W
R th(c-h)
0.15°C/W
Weight
160g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCC95-16io1B for IXYS replacement. See TT92N16KOF for Techsem Pressure Contact Alternative
Fastron Electronics AM5A-A-DV1-A DC Ammeter DC Voltmeter & Transmitter
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5A-A-DV1-A
Alarm Output
1 x High or Low C/O Relay Alarm with Reset
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110- 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles