Thyro-A-3A-400-280-HF-3, Three Phase SCR Controller 280 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-280-HF-3, Three Phase SCR Controller 280 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-280-HF-3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,387.48
$7,537.23 inclGST -
KNL400-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 400 Amps, 24VAC Coil
Heavy Item - No free ShippingIskra Doo KNL400-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 400 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL400-00-24VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 400 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional Snap On up to Four G350 (2NO + 1NC or 1NO+2NC Depending on mounting position) Trip Delay Time 2-10ms Electrical Life 700,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 52.5W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 9.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display
Rishabh Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V (Programmable) Free Program Software 300mS response time PC 94 UL V0 Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con CM44111411 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4 x 4-20mA/0-20mA/0-10V User Selectable and Programable Relay Output N/A Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 100 - 600VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-285VAC/DC Accuracy 0.2% Current, Voltage (0.5% Power) Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog Brand Comparison to Iskra UMT540 or MT540 Series
$589.00
$695.02 inclGST -
M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC
Free Aus Post Shipping for $300 SpendHOBUT M850-LDD, DC kWh Meter 96x96mm, 800VDC, 75mV Shunt Connected, RS485, Lockable,100-240VAC or 100-420VDC 0-10 Amp direct connect, or 50,75mV Shunt Backlit LCD Lockable Optional RS485 communication up to 19,200 bit/s Universal Supply 100-440VAC, or 100-420VDC Accuracy class 1 The meter is intended for measuring, and monitoring DC electrical power networks. The meter records DC power according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Optional Pulse Output Graphic LCD with illumination Specification HOBUT Part Number M850-LDD Functions DC Energy Meter Supply Voltage 100-440VAC, or 100-420VDC 0.5VA Nominal Measurement Range 15-150VDC or 30-300VDC, or 80-800VDC Maximum Measurement Range 15-800VDC Nominal Current Input 1A-10A or 50mV/75mV Shunt Infra Red Output N/A Tariff Input N/A (Optional) Accuracy Class 1 (I,U) Mounting Panle Mount Real Time Clock 1min/month (30ppm) Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 4kV RS485 Optional Weight 500g Certification CE Factory Pack Qty 1 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Operating Temperature -20 →+60 °C Datasheet Product Datasheet
-
K2210, Round Style Core Balanced Toroidal CT's, 210m Aperture, 271x75mm Aperture
Hobut CTBR470, Square Style Core Balanced Toroidal CT's (CBCT), 160x470mm Internal Diameter Features Very low differential current measurement Applications Earth Leakage Specification Northern Design Part Number K2210 500mA - 10 Amp Technology Core balanced (CBCT) Aperture Size 210m Aperture, 271x75mm Aperture Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$1,065.00
$1,256.70 inclGST -
Thyro-A-3A-400-350-HF-3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-350-HF-3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-350-HF-3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$7,984.35
$9,421.53 inclGST -
DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation
LEM DV 1000 Digital Voltage Transducer, Vpn = 1000V, +/-15...24VDC, 50mA output, 18.5kV Isolation Features Bandwidth DC to 12kHz Closed loop transducer using Hall effect Digital Transducer (ASIC based) Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Drop in replacement for LV100-2000 Specification LEM Part Number DV 1000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1000V Measurement Range +/- 1500V Output 50 mA @Vpn Isolation 18.5 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw Unit Weight 1000g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$1,564.00
$1,845.52 inclGST -
Rish Con M+ CM44111211, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display
Rishabh Rish Con M+ CM44111211, , Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V Outputs, 2 x Relay Outputs, USB Programming Port, Modbus RTU Comms, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V (Programmable) Free Program Software 300mS response time PC 94 UL V0 Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con M+ CM44111211 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 2 x 4-20mA/0-20mA/0-10V User Selectable and Programable Relay Output 2 Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 100 - 600VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-285VAC/DC Accuracy 0.2% Current, Voltage (0.5% Power) Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog Brand Comparison to Iskra UMT540 or MT540 Series
$629.00
$742.22 inclGST -
D53TP25D, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, LED Status Indicator
Free Aus Post Shipping for $300 SpendCrydom D53TP25D, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, LED Status Indicator Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number D53TP25D Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 25 Amp (rms) per Phase Surge Capability 239 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
DK 100 C10, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-10V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 C10, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C10 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-10V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
MX11CCC, DC Contactor Milspec SPST-NO, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11CCC, DC Contactor Milspec SPST-NO, 150 AMP, 12-48VDC, 24VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11CCC Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 24VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
HS501DR + HA4850, Panel or Din Rail Mount Solid State Relay, 90-280VAC Control Input, 90-530VAC Output, 10 Amps
Free Aus Post Shipping for $300 SpendCrydom HS501DR + HA4850, Panel or Din Rail Mount Solid State Relay, 90-280VAC Control Input, 90-530VAC Output, 10 Amps Features Ratings from 25A to 125 Amp @48-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Part Number HS501DR + HA4850 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 90-280VAC Load Current 10 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature LED Status Indicator Mounting Style Din Rail or Panel Mount Load Voltage Range 48-530VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:79.9mm x W:45mm x D:40.3mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS501DR Series 1 HD Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies