Search results for "텔레@upcoin24``이더리움전송대행리플매입"
-
KNL500-00-415VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 500 Amps, 415VAC Coil
Heavy Item - No Free ShippingIskra Doo KNL500-00-415VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 500 Amps, 415VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL500-00-415VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 500 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional G350 Snap On (2NO + 1NC or 1NO + 2NC) Trip Delay Time 2-10ms Electrical Life 700,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 415VAC Power Dissipation 68.6W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 17kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
AAN5893 (AAN5781) 11.204.587 MAHLE - Letrika(Iskra) Alternator, 14VDC 140Amp
Heavy Item - No Free ShippingISKRA LETRIKA AAN5893 (AAN5781) 11.204.587 MAHLE - Letrika(Iskra) Alternator, 14VDC 140Amp OEM MAHLE(Letrika) AAN5893 (AAN5781) 11.204.587 (MG 122) Letrika IA1494 See IA1011 for 80 Amp alternative Specification ISKRA (MAHLE) Part Number AAN5893 (AAN5781) 11.204.587 ISKRA/LETRIKA/MAHLE AAN5893 (AAN5781) 11.204.587 IA1494 MG 122 (Replaces 11.203.899, MG689) Voltage 14VDC Current 140 Amp No of Pinon Teeth 9 Module 3mm Unit Weight 6.5kg Factory Pack Qty 1 Applications Manufacturer Vehicle Type Engine Ltr Date AGCO TRACTORS Perkins 1103, 1104 - Cross Reference Manufacturer Manufacturer P/N AGCO 8366 742 43 AGCO ACV0204490 AGCO V836674243 Spare Parts Pos. Letrika P/N MAHLE P/N Description 2 16.908.875 MGX 1103 Drive end bracket 3 16.908.961 MGX 746 Bearing 4 16.350.609 MGX 1260 Stator 5 16.300.295 MGX 949 Bolt 6 16.363.111 MGX 1650 Rotor 7 16.915.726 MGX 957 Pulley 9 16.915.145 MGX 836 Bearing 10 16.915.687 MGX 1323 Rectifier 11 16.915.146 MGX 835 Rear-end bracket 13 16.420.568 MGX 411 Protecting cover 15 16.908.881 MGX 281 Regulator
-
Thyro-A-3A-400-130-H3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-130-H3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-130-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$5,435.10
$6,413.42 inclGST -
Thyro ECO A3A 400-50 E L3, 3 Phase, SCR Controller 50 Amp Ratings, Phase(VAR), Burst(TAKT), Switch Operating Mode, Voltage Control only
Advanced Energy Thyro ECO A3A 400-50 E L3, 3 Phase, SCR Controller 50 Amp Ratings, Phase(VAR), Burst(TAKT), Switch Operating Mode, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage Control Programmable Relay Alarm Output 3 Phase, Phase Angle, Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Fully enclosed IP20 Phase Angle(VAR), and Burst Fire(TAKT) switching Removable Cover USB Configuration/Bias Setting Synchronisation Function Digital Alarm Output Load Monitoring Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Special Features Economic Model Specification Advanced Energy Part Number Thyro A 3A ECO Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C SCR Configuration 3 Phase AC Switch Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 25 to 125 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 10kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$3,291.75
$3,884.27 inclGST -
FRS 2500-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
LEM FRS 2500-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SBI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$475.00
$560.50 inclGST -
G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G22WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 50 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
Sentinel 3+ Battery Impedance, Voltage and Temperature Sensor Gen 3+, Accuracy 0.5%, S-Bus Output
Free Aus Post Shipping for $300 SpendSentinel 3+ Battery Sensor Gen 3+, DIN Rail Mount Compact and versatile 3 in 1 Battery sensor for monitoring of critical battery systems, included Flooded Cell, and VLRA types. The Sentinel 3+ is a state of the art, System on Chip (SoC) digital transducer designed to monitor VRLA, gel or flooded stationary battery systems. Data is transmitted over a dedicated communication bus to proprietary and non-proprietary devices Features Din Rail Mount, Compact Design LED status indicator Temperature patch for direct battery measurement Communication interface isolation 2.16 kV Fast, simple fittings , Voltage, Temperature and True AC Impedance Measurement S-Bus Output (Interface with OEM equipment) Suitable for Transformerless UPS systems (may require Common mode Isolator) Isolated plastic case recognised according to UL94-V0 Advantages Excellent sensitivity, accuracy, and repeatability High current stimulation for secure impedance measurement Improved immunity to Common Mode transients in newer UPS topologies (ie. transformerless, using fast IGBTs and/or a floating battery with respect to earth ground). Applications UPS Telecommunications Battery supplied applications Application Domains Energy & Automation Industrial. Utilities Fire & Safety system Remote monitoring LEM Part Number BM Sentinel 3+ Technology SoC 3 in 1 sensor CE Approved Yes Supply Voltage 0.9 .. 16VDC @ 30mA Voltage Measurement Range 0.9 .. 16VDC @ 30mA Temperature Measurement Range -10°C / 70°C Output S-Bus Digital protocol Isolation 2.16kV (AC, 50Hz, 1 min) S-Bus Baud Rate 9600 bps Mounting Style Din Rail Mount Operating Temperature Range -10°C / 70°C Accuracy 0.5% Termination Style 6 Pin Connector (for BM CBL POW 0.4/0.6M) Unit Weight 70g Factory Pack Qty 6 Datasheet Used to monitor and measure battery Impedance, Voltage, and Surface Temperature. Product Datasheet S-Bus Protocol Information OEM Software Tools Sentinel 3 Commander Test Program Sentinel Troubleshooting Harsh EMC Application Notes In a UPS, the current drawn by the inverter contains line frequency harmonic components (mostly 2nd, 4th and 6th). Part of this ripple current flows through the battery, to which is connected the Sentinel. As the Sentinel itself uses an excitation current for the impedance measurement, so the presence of ripple current can interfere with the measurement and thus cause errors. The table below quantifies the additional error resulting from 1A rms of ripple current, for different combinations of ripple current harmonics and bloc voltage. Table 1: Additional errors for impedance measurement due to ripple current (See datasheet) Notes: The error values are the maximum, and are normalized for 1A rms of ripple current. The error is proportional to the ripple current; for example, if the ripple current was 2A rms the error will increase by factor 2.
-
CV 3-500 Digital Voltage Transducer Flux Gate, Vpn = 350V, +/-15VDC, 10V output, 6kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 3-500 Digital Voltage Transducer Flux Gate, Vpn = 350V, +/-15VDC, 10V output, 6kV Isolation Features Bandwidth DC to 300kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 350V Measurement Range +/- 500V Output 10V @Vp(max) Isolation 2.5 kV Bandwidth DC-300 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
LTC 600-T C/L Hall Effect Current Sensor, 600 Amp, 100mA Output, +/-15..24V, Panel Mount, w/ busbar, X = 0.7%
Free Aus Post Shipping for $300 SpendLEM LTC 600-T Closed Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 100 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
LND2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Low Noise, Low EMC/RFI
Free Aus Post Shipping for $300 SpendCrydom LND2475, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Low Noise, Low EMC/RFI Features • Ratings from 25A to 75 Amp @ 24-280 VAC • SCR output for heavy industrial loads • Zero voltage or instantaneous turn-on outputs • UL/CSA/VDE Approved, CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers • AC & DC control types • Direct bond copper substrate • EMC compliant to Level 3 • Direct power lead frame • Epoxy free design Spec Crydom Part Number LND2475 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 75 Amp (rms) Surge Capability 1145 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Rish Xmer 140-100H (45) 2500/5 Class 0.5, 45VA, ⌀ 86mm or 101 x 31mm Busbar
Heavy Item - No Free ShippingRishabh Rish Xmer 140-100H (45) 2500/5 Class 0.5 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 140-100H (45) 2500/5 Class 0.5 Technology AC Current Transformer Ratio 2500/5 Aperture Size ⌀ 86mm or 101 x 31mm Busbar VA Rating 45VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 2500Amp x 1.2 Termination Style Screw Unit Weight 1.2kg Factory Pack Qty 9 Datasheet Product Datasheet
-
KNL500-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 500 Amps, 24VAC Coil
Heavy Item - No free ShippingIskra Doo KNL500-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 500 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL500-00-24VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 500 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional G350 Snap On (2NO + 1NC or 1NO + 2NC) Trip Delay Time 2-10ms Electrical Life 700,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 68.6W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 17kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue