Trent 450NBBF Semiconductor I²t Fuse, 250VAC, 450 Amp, aR BS88 Style
Features
British Standard Fuse Links Package
Wide Range of I²t
Ratings up to 1050 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
250 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
450NBBF
Fuse Type
I²t AR Class
Nominal Voltage
250VAC @ 50Hz
I²t Rating
80000 A²/s
Nominal Current (RMS + DC)
450 Amp
Tested Breaking Capacity
200kA @ 250VAC
Dimensions
82 x 37.3 x 70.4mm
Hole Centers
65.5 - 48.2mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watt Loss
54W
Termination Style
M6
Unit Weight
170g
Factory Pack Qty
10
Datasheet
Product Datasheet
Cross Reference Chart
Eastron Smart X96-5I-2-1-C, Panel Mount Multifuction Meter, Class 0.5s, 65-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Ethernet Comms, 65-480VAC Aux
Metering and Numerical Display
Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency
Ethernet communication as standard
True RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5s
Optional 2 or 4 tariff inputs,
Digital Output and Input
Ethernet communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD with Dual Metering and PF Displays
Specification
Eastron Part Number
Smart X96-5I-2-1-C
Functions
Power Quality Meter, Energy Meter
Supply Voltage
65-480VAC < 7VA/3.5W
Nominal Measurement Range
65-480V L-N, 1/5 Amp
Maximum Measurement Range
280V L-N, 1/5 Amp
Pulse Outputs
2 x Digital Outputs (shared with Alarm function)
Alarm
2 x Digital Outputs (shared with Pulse function)
Tariff Input
1 (Optional 4 x )
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 1 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
2.5kV (1 Min)
Ethernet
2400-38400 b/s
Weight
500g
Certification
MID, UL
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Operating Temperature
-25 →+55 °C
Datasheet
Product Datasheet
User Manual
Modbus Registers
Eastron Smart Smart X96-5J-2-1-C, Panel Mount Multifuction Meter, Class 0.5s, 65-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Ethernet Gateway, 65-480VAC Aux
Ethernet Gateway Function
Metering and Numerical Display
Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency
Ethernet communication as standard
True RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5s
Optional 2 or 4 tariff inputs,
Digital Output and Input
Ethernet communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD with Dual Metering and PF Displays
Specification
Eastron Part Number
Smart X96-5I-2-1-C
Functions
Power Quality Meter, Energy Meter
Supply Voltage
65-480VAC < 7VA/3.5W
Nominal Measurement Range
65-480V L-N, 1/5 Amp
Maximum Measurement Range
280V L-N, 1/5 Amp
Pulse Outputs
2 x Digital Outputs (shared with Alarm function)
Alarm
2 x Digital Outputs (shared with Pulse function)
Tariff Input
1 (Optional 4 x )
Accuracy
Class 0.5s (I,U,F,PF,θ,THD) Class 0.5(Active), Class 1 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
2.5kV (1 Min)
Ethernet
2400-38400 b/s (Gateway Function)
Weight
500g
Certification
MID, UL
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Operating Temperature
-25 →+55 °C
Datasheet
Product Datasheet
User Manual
Modbus Registers
PGFM-211-B-A1, GFCI Lineguard Ground Fault Protection Relay for Single or Split Phase Systems, 5mA Detection, 50 Amp Max Ipn, 240VAC Supply, Panel Mount, Auto Reset, Note: Requires Suitable Air Pax Breaker
Features :
Suitable for Air Pax Breaker LEL Series
Applications :
On Board Vessel Earth Leakage Detection (Marine)
Specification
Sensata - Klixon Part Number
PGFM-211-B-A1
Supply Voltage
240VAC
Dimensions
55.4mm x 93.2mm x 83.3mm
Application
Earth Leakage Detection 5mA - 50 Amp
Trip Level
+/-5mA Nominal (Auto Reset)
Relay
Auto Reset, Requires Air Pax LEL Series Breaker
Protection
IP20
Approvals
E-11 GFP - UL 943 Category FTTJ2 when used in tandem with Airpax LEL series
Trip Time of Assembly
100mS or Less (60mS nominal)
Sensing Coil Voltage Limit
600VAC max
Operating Temnperature
-35 to 66 Deg C
Weight
200g
Mounting Style
Din Rail
Datasheet
Product Datasheet
Trent H31/180M-F & FCR-400-120R, Three Phase Proportional Phase Control Module with Heatsink, 4-20mA,0-10V,500K POT Input, 400VAC, 70 Amp Per Phase @ 50 Deg C
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
H31/180M-F & FCR-400-120R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
70 Amp (rms) @ 50 Deg C
Surge Capability
1050 Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
L:220 x W:125 x D:180mm
Unit Weight
4.3kg
Factory Pack Qty
20
Datasheet
FCR-400-120R
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Iskra Module ISPRO C 40/275, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 275VAC, Class II / Type 2 / C
Specifications
Iskra Doo part number
786.600.196.000
Nominal Voltage
275VAC
No of Poles
1
Category IEC / EN / VDE
Class II / Type 2 / C
Location of use
In ISPRO Products
Protection modes
L/N-PE
Protective element
MOV + GDT
Surge discharge rating
Imax up to 40 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Iskra Module ISPRO C 40/440, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 440VAC, Class II / Type 2 / C
Specifications
Iskra Doo part number
Module ISPRO C 40/440
Nominal Voltage
440VAC
No of Poles
1
Category IEC / EN / VDE
Class II / Type 2 / C
Location of use
In ISPRO Products
Protection modes
L/N-PE
Protective element
MOV + GDT
Surge discharge rating
Imax up to 40 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Schurter 4435.0254 TA35-CFTBL100C0, 1 Pole Rocker Switch, Non Latched, 10 AMP, 240VAC, 60VDC with Thermal Overload Protection, Faston Connection, Black with White I/O
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
Thermal circuit breaker
1-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4435.0254 TA35-CFTBL100C0
Functions
1 Pole Rocker Switch with Bimetal Thermal Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 60VDC
Nominal Current Range
10 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Insulation Resistance
500VDC
Illumination
None
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
60g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter 4435.0478 TA35-CFTBL160C0, 1 Pole Rocker Switch, Non Latched, 16 AMP, 240VAC, 60VDC with Thermal Overload Protection, Faston Connection, Black with White I/O
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Rocker Switch
Thermal circuit breaker
1-pole - Power tools
Manual ON/OFF type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 5000 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4435.0254 TA35-CFTBL160C0
Functions
1 Pole Rocker Switch with Bimetal Thermal Circuit Breaker
Nominal Voltage
240VAC @ 50Hz or 60VDC
Nominal Current Range
16 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Insulation Resistance
500VDC
Illumination
None
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 0.8 Amp, 1kA, Threaded neck type, Reset Type, Quick Connect Terminals, w/ Auxiliary Contacts 4410.0084 T12-211S-1
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction
Description
Threaded neck type
Thermal circuit breaker
1-pole with Auxiliary Contact- Motors
Reset type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect with Auxiliary Contact
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 500 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4410.0084 T12-211S-1
Functions
1 Pole Thermal Circuit Breaker with Aux Contact, Reset Type
Nominal Voltage
240VAC @ 50Hz or 28VDC
Nominal Current Range
1 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-5 to 60 Deg C
Insulation Resistance
500VDC
Dielectric Strength
4kV (50Hz)
Short Circuit Current
1kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Eastron Smart X96-5-MID, Panel Mount Multifuction Meter, Class 1, 173-480VAC, 1A/5A CT input, 30 Parameter, 2 x Digital Pulse/Alarm Outputs, Modbus RTU RS485 Comms, Self Powered, MID Approved
Metering and Numerical Display
Adjustable tariff clock (Optional 4 Tarriffs), display of electric energy consumption in optional currency
Modbus RTU as standard
True RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 30 quantities (U, I, P, THD, IHD, S, PF, PA, f, f, MD, etc.).
Accuracy class 1
Optional 2 or 4 tariff inputs,
Digital Output and Input
Ethernet communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal or AC power supply
Graphic LCD with Dual Metering and PF Displays
Specification
Eastron Part Number
Smart X96-5-MID
Functions
Power Quality Meter, Energy Meter
Aux Supply
Through Measurement Inputs
Nominal Measurement Range
173-480V L-N, 1/5 Amp
Maximum Measurement Range
280V L-N, 1/5 Amp
Pulse Outputs
2 x Digital Outputs (shared with Alarm function)
Alarm
2 x Digital Outputs (shared with Pulse function)
Tariff Input
1 (Optional 4 x )
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
2.5kV (1 Min)
RS485
2400-38400 b/s
Weight
500g
Certification
MID, UL
Factory Pack Qty
1
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Operating Temperature
-25 →+55 °C
Datasheet
Product Datasheet
User Manual
Modbus Registers
Trent NBR-FR22GR69V20T Series 20 Amp 690V Semiconductor I²t Fuse Cartridge Style
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 120 Amp
Quick Release with RT18-125L fuse holder
DIN Rail Mount with RT18-125L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FR22GR69V20T
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
260 A²/s
Nominal Current (RMS + DC)
20 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
58 x 21mm
Fuse Holder
RT18-125L
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
13.8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
RT18-125L
Datasheet