P43 221300M0, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display
Lumel P43 221300M0, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Lumel Part Number P43 221300M0 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4 x 4-20mA/0-20mA/0-10V User Selectable Relay Output N/A Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 20 - 480VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-253VAC/90-320VDC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet
$733.00
$864.94 inclGST -
Iskra Doo PFC-CX-12R Power Factor Regulator (Beluk BLR-CX 12RL), 12 Step, 110-480V 50/60HZ, See Rebadged PFR-X+ 12R
Free Aus Post Shipping for $300 SpendIskra Doo PFC-CX-12R Power Factor Regulator, Controller (Beluk BLR-CX 12RL and Vishay Estamat PFC-12N), 12 Step, 110-480V 50/60HZ, Rebadged PFR-X+ 12R Single CT Sensing Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 230VAC Aux Supply Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Iskra Doo Part Number PFC-CX-12R Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 90-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/10Amp Switch Delay Time 1s - 1200s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 50 - 1200s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 12 Smallest Capacitor Current 10mA CT Input Range 0 - 6 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms N/A Termination Style Screw Weight 700g Certification IEC 654-1 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet User Manual Modbus RS485 User Manual Iskra Quick Setup Guide Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog) Alternative in Stock Beluk BLR-CX12R
-
AAN8145 11.204.17, MAHLE - Letrika(Iskra) Alternator, 14VDC 150Amp, Replaces AAN5333
Heavy Item - No Free ShippingISKRA LETRIKA AAN8145 11.204.17, Alternator, 14VDC 150Amp, Replaces AAN5333 OEM MAHLE(Letrika) IA1198, 11204233, AAN8145, MG694, 11204174, AAN5333, MG30, 11203882, AAN5776, 11203825, AAN5745, 11203734, AAN5708, AAN5333 Specification ISKRA (MAHLE) Part Number AAN8145 11.204.17 ISKRA/LETRIKA/MAHLE IA1198, 11204233, AAN8145, MG694, 11204174, AAN5333, MG30, 11203882, AAN5776, 11203825, AAN5745, 11203734, AAN5708 Voltage 14VDC Current 150 Amp No of Pinon Teeth 9 Module 3mm Unit Weight 8.5kg Factory Pack Qty 1 Applications MAKE MODEL TYPE ENGINE POWER YEARS CASE PUMA 170 NEF Tier 4; 167HP 6.7 2011.01- CASE PUMA 170 CVX NEF Tier 4; 167HP 6.7 2010.12- CASE PUMA 180 CVX NEF Tier 3; 182HP 6.7 2010.12- CASE PUMA 185 NEF Tier 4; 185HP 6.7 2011.01- CASE PUMA 185 CVX NEF Tier 4; 185HP 6.7 2010.12- CASE PUMA 200 NEF Tier 4; 200HP 6.7 2010.12- CASE PUMA 200 CVX NEF Tier 4; 200HP 6.7 2010.12- CASE PUMA 215 NEF Tier 4; 215HP 6.7 2010.12- CASE PUMA 215 CVX NEF Tier 4; 215HP 6.7 2010.12- CASE PUMA 225 CVX NEF Tier 3; 224HP 6.7 2009.01- CASE PUMA 230 CVX NEF Tier 4; 228HP 6.7 2010.12- CASE T 7030 NEF 6-cyl; Tier III (167HP) 6.7 - CASE T 7040 NEF; 6-cyl Tier III (182HP) 6.7 - CASE T 7050 NEF; 6-cyl Tier III (197HP) 6.7 - CASE T 7060 NEF; 6-cyl Tier III (213HP) 6.7 - CASE T 7070 NEF 6-cyl; Tier III (225HP) 6.7 - NEW HOLLAND T7 T7.185 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 188HP 6.7 2011.01- NEW HOLLAND T7 T7.190 FPT NEF; 6-cyl Tier 4; 190HP 6.7 2014.01- NEW HOLLAND T7 T7.190 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 190HP 6.7 2014.01- NEW HOLLAND T7 T7.200 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 203HP 6.7 2011.01- NEW HOLLAND T7 T7.220 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 218HP 6.7 2010.12- NEW HOLLAND T7 T7.230 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 234HP 6.7 2010.12- NEW HOLLAND T7 T7.240 NEF; 6-cyl 6.7 - NEW HOLLAND T7 T7.245 NEF; 6-cyl. 6.7 - NEW HOLLAND T7 T7.260 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 260HP 6.7 2010.12- NEW HOLLAND T7 T7.270 AUTO COMMAND FPT NEF; 6-cyl Tier 4; 269HP 6.7 2010.12- NEW HOLLAND T7030 Auto Command NEF Tier 3; 167HP 6.7 2007.01- NEW HOLLAND T7040 Auto Command NEF Tier 3; 182HP 6.7 2007.01- NEW HOLLAND T7050 Auto Command NEF Tier 3; 197HP 6.7 2009.06- NEW HOLLAND T7060 NEF 6-cyl; 210FP 6.7 2007.01- NEW HOLLAND T7070 Auto Command NEF Tier 3; 225HP 6.7 2009.06- NEW HOLLAND (SPERRY NEW HOLL.) T7030 204HP 6 cyl 6.7 - NEW HOLLAND (SPERRY NEW HOLL.) T7040 218HP 6 cyl 6.7 - NEW HOLLAND (SPERRY NEW HOLL.) T7050 234HP 6 cyl 6.7 - NEW HOLLAND (SPERRY NEW HOLL.) T7060 238HP 6 cyl 6.7 - Cross Reference CNH / FIAT AGRI 87573243 DELCO REMY DRA0816 FIAT 84141455 LESTER 23842 MAHLE LETRIKA (ISKRA) IA1198, 11204233, AAN8145, MG694, 11204174, AAN5333, MG30, 11203882, AAN5776, 11203825, AAN5745, 11203734, AAN5708 SPAREX 36234 Spare Parts Spare Parts Page
-
GXC16CEBX, CAN Bus Contactor SPST-NO, 600+ AMP, 12-800VDC, 24VDC Coil, 8 Pin Deutsch Connector, SPST-NO Auxiliary Contact, IP67, IP69K
Heavy Item - No Free ShippingGigavac GXC16CEBX, CAN Bus Contactor SPST-NO, 600 AMP, 12-800VDC, 24VDC Coil, 8 Pin Deutsch Connector, SPST-NO Auxiliary Contact, IP67, IP69K Features CAN Bus Comms Voltage Sensing Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GXC16CEBX Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 600 Amp Voltage Sensing NO Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Voltage Sensing YES Comms CAN BUS Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 & Deutsch 8 Pin Connector Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
88970533, Essential Series CT107, 7" HMI Touch Screen(88970534) with M3 Cable, 24VDC, RS485 Modbus RTU
Free Aus Post Shipping for $300 SpendCrouzet 88970533, Essential Series CT107, 7" HMI Touch Screen(88970534) with M3 Cable, 24VDC, RS485 Modbus RTU TFT-LCD resistive touch screen Fan less cooling system 32 bit 600 Mhz or 1 Ghz Cortex-A8 processor Built-in RTC Direct communication with M3 programming port Modbus RS485 protocol (drivers for M3, EVO and em4) Modbus TCP/IP protocol (drivers for M3, EVO and em4) Integrated VNC server Additional functions provided by Crouzet Touch programming software (e-mails,recipe database, enhanced security…) CE mark, cULus listed Specification Crouzet Part Number 88970534 (CT107) + 88970534 Function Human Machine Interface (Touch Screen) + Connection Cable Nominal Voltage 24VDC (19.2 - 28.8VDC) @ 500mA Display Size 7" Resolution 800 x 480 Brightness 300 cd/m² Storage Memory 128MByte RAM Memory 128MByte USB Host USB 2.0 Ethernet N/A Port RS232 COM1 Male Port RS485 COM1 2/4 wires Male, COM3 2 wires Male Voltage Resistance 500VAC (1 Min) Dimensions 200.4 x 146.5 x 34 mm / 7.89 x 5.77 x 1.34” Real Time Clock 5 Years with CR2032 Battery Termination Style Screw Weight 520g Certification CE Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet HMI Touch Datasheet HMI Touch Brochure Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14 Compatibility Built in Communications driver compatible with Millenium 3, Millenium EVO, and EM4 PLC's. See our PLC Section for Pricing and Specification
-
MT408-41, AC Current Transducer, Class 0.5, 0-6Amp 50/60Hz Average RMS Measurement, Self Powered, 0-1mA output, Fixed zero and span
Free Aus Post Shipping for $300 SpendIskra Doo MT408-41 Series Single Phase AC Current Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-1mA analogue output for Moving Coil Voltmeter Average RMS values of voltage Self Powered Features : Measurement of up to 6 Amp AC Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT408-41 Functions Single Phase AC Current Transducer Supply Voltage Self Powered Nominal Measurement Range 0-6 Amp Output 0-1mA Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
-
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply
DC-0-200-420B-1.0, Hall Effect DC Current Transducer, 0-200 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-200 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-200-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-200 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
CTBR470, Square Style Core Balanced Toroidal CT's, 160x470mm Internal Diameter
Hobut CTBR470, Square Style Core Balanced Toroidal CT's (CBCT), 160x470mm Internal Diameter Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTBR470 Technology Core balanced (CBCT) Aperture Size CTBR470->160x470mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$992.00
$1,170.56 inclGST -
DH 800 B420L B, Current Transducer, 800Amp Bipolar, 4-20mA output, 24V loop powered
Free Aus Post Shipping for $300 SpendDH 800 B420L B Current Transducer, 800Amp Bipolar, 4-20mA output, 24V loop powered Product Datasheet , Obsolete - No replacement in single package. Contact us for a solution
-
Elite E500R-54D2, Panel Mount Power Quality Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (31st), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure Elite E500R-54D2, Panel Mount Power Quality Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (31st), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51D2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/140mm Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet Cross Reference The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300 ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650 ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760 ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330 ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60 PM 5560 ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60 DM6200H ACCUVIM-EL (+ IEC 61850) PM2220 ACCUVIM-II R +Ethernet PM2230 / DM2120 (LED) PM 5350
$1,580.00
$1,864.40 inclGST -
DVL 2000/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181
Free Aus Post Shipping for $300 SpendLEM DVL 2000/SP1 Digital Voltage Transducer, Vpn = 2000V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation, SMS6GE6 Burndy connector output, DTR0000333181 Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 SMS6GE6 Burndy connector output, DTR0000333181 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 2000/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 2000V Measurement Range +/- 3000V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SMS6GE6 Burndy connector output, DTR0000333181 Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAANNA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer