DTC1-A/M1-2O, DIN Rail Mount Transmitter, Multirange Thermocouple Input, 24VAC/DC, 2 x 4-20mA Outputs
Free Aus Post Shipping for $300 spendFastron DTC1-A/M1-2O, DIN Rail Mount Transmitter, Multirange Thermocouple Input, 24VAC/DC, 2 x 4-20mA Outputs Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M1-2O Control Output 2 x 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Output Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display
Free Aus Post Shipping for $300 SpendCrouzet 88974031, Millenium 3 Essential CB20-12I/8O R, 12 x On/Off inputs, Incl 6 analogue inputs, 8 x Static relay outputs incl 4 x PWM output, 24 VDC Supply, Green Display Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Allow the use of the entire library of specific functions blocs of the software workshop Extended temperature range (-20 °C →+70 °C) Analogue inputs 0-10 VDC, Potentiometer, NTC, LDR (0-20 mA/Pt100 with converters) Open to XN network communication extensions, digital I/O, analogue, Pt100 extensions HMI Screens Available Specification Crouzet Part Number 88974031 (CB20-12I/8O R) Analogue Inputs 0-10VDC (x6) Digital Inputs 12/24VDC (4.4mA @ 12VDC) (x16) Digital Outputs Relay, 5-30VDC,24-250VAC @ 10mA minimum (x10) PWM SSR Output 12-24VDC @ 500mA (x4) Expandable Yes LCD Display None Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VDC (21.6 - 28.8VDC) Termination Style Screw Weight 350g Certification CE, UL, CSA, GL Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Selection Chart Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
NX1-11, Temp Controller, 48x24mm, 100-240VAC, Multirange Input, Multirange SSR/4-20mA Heating Output, Relay Cooling Output, Setup for Relay Heating Output, 1 Alarm
NX1-11, Temp Controller, 48x24mm, 100-240VAC, Multirange Input, Multirange SSR/4-20mA Heating Output, Relay Cooling Output, Setup for Relay Heating Output, 1 Alarm Multirange Dual Output and Input, User Selectable Multirange Output (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number NX1-11 Control Output 1 (Heat) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4), or 4-20mA, or SSR (12VDC, 30mA 600 Ohm) Control Output 2 (Cool) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet NX Series Brochure NX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$269.00
$317.42 inclGST -
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-5 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-5A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-5 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
VX4-UCMA-A1, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, 4-20mA Output, Relay Cooling 1 Alarm
VX4-UCMA-A1, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, 4-20mA Output, Relay Cooling 1 Alarm Multirange Input (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number VX4-UCMA-A1 Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals. Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 N/A Option 2 Cooling Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Mounting Style 48 x 48mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet VX Series Brochure VX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$245.00
$289.10 inclGST -
ACD15AR/M Servo Motor Controller, 96x96mm, 100-240VAC
Free Aus Post Shipping for $300 SpendShinko ACD15AR/M Series Digital Indicating Servo Controllers • Program control, converter function are standard features • 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) • Drip-proof / Dust-proof IP66 (front panel only) • 9-step pattern (for SV and time) is a standard feature • UL/CSA Approved • Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) • Each unit needs just 60 mm depth panel space • EC Compliant (Details) Specification Shinko Part Number ACD15AR/M Control Output 4 - 20mA Input Multirange (refer to datasheet) Alarm 2 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 None Mounting Style 96 x 96mm Panel Mount Supply Voltage 100 - 240VAC Termination Style Screw Weight 330g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet ACD Series Brochure ACD Series Instruction Manual ACD Series RS485 Comms Instruction Manual Delivery 3-4 weeks delivery if not in stock
-
88981123 em4 Alert 3G, 16 digital inputs (including 4 High Speed, 8 analog 0-10 V / potentiometers and 4 analog 0-10 V / 4-20 mA), 10 digital outputs (including 2 solid states 0.5 A PWM, 2 relays 6 A and 6 relays 8 A)
Free Aus Post Shipping for $300 SpendCrouzet 88981123 em4 Alert 3G Programmable Logic Controllers 3G Comms built in Up to 104 I/Os - 16 DI (4 HighSpeed / 8 AI) 10 x DO (2 x Solid State 0.5Amp PWM, 2 Relays 6 Amp, and 6 Relays 8 Amp) Wireless Programming & Control with native 3G and Crouzet Virtual Display Modbus RTU Network (Slave) Local datalog management Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications HMI Screens Available Specification Crouzet Part Number 88981123 (em4 Alert 3G) Analogue Inputs 12 x 0 - 10VDC, (4 High Speed) Digital Inputs 24VDC @ 2.1mA (8 Standard and 4 High Speed) Digital Outputs Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp) PWM SSR Output 2 Expandable Yes Comms 3G. (RS485, Bluetooth,Ethernet,Standard) and Wifi versions available LCD Display Yes Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VAC (21.6 - 28.8VAC) Termination Style Screw Weight 350g Environmental Reach, RoHS, Halogen free 1272/2008/CE Certification CE, cULus Listed Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14
-
DCM230 2-4-1-1 V1, DIN Rail Mount DC kWh Meter, 5-60VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
Eastron Europe DCM230 2-4-1-1 V1, DIN Rail Mount DC kWh Meter, 5-60VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved 45/60/75mV Shunt Connect RS 485 communication up to 38,400 bit/s as standard 1 x Pulse Outputs (1 Configurable) Bidirectional Measurement The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number DCM230 2-4-1-1 V1 Functions DC Energy Meter Supply Voltage 9-60VDC Nominal Measurement Range 5-60VDC Maximum Measurement Range 5-60VDC Nominal Current Input Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt Pulse Output 1 x Configurable 60/100/200ms Tariff Input N/A Accuracy Class 1 (I,U,kW,kWh) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s Weight 250g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Utility EEM Meter Setting Software Utility
$249.00
$293.82 inclGST -
FTA-005-420B-24, DC Current Transducer, +/-5 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420B-24, DC Current Transducer, +/-5 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-5 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-5A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-5 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
RX4L-U-D-D-2-96-N-N-N-N-N-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms
RX4L-U-D-D-2-96-N-N-N-N-N-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms Mutirange Input 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 70 mm depth panel space EC Compliant Specification Fastron Part Number RX4L-U-D-D-2-96-N-N-N-N-N-N Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) 4-20mA Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 N/A Mounting Style 96x96mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 450g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet RX4L Series Instruction Manual
$295.00
$348.10 inclGST -
RX4L-U-D-N-2-96-A-N-N-N-W-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms, 2 x SV Input, Retransmisison Output
RX4L-U-D-N-2-96-A-N-N-N-W-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms, 2 x SV Input, Retransmisison Output Mutirange Input 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 70 mm depth panel space EC Compliant Specification Fastron Part Number RX4L-U-D-N-2-96-A-N-N-N-W-N Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) N/A Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 4-20mA PV Retransmission, 2 x SV (Setpoint) Mounting Style 96x96mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 450g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet RX4L Series Instruction Manual
$245.00
$289.10 inclGST -
Xmer CT Split 125/50SC 250/5 Class 1, 2.5VA 55 x 85mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 125/50SC 250/5 Class 1, 2.5VA 55 x 85mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 125/50SC 250/5 Class 1, 2.5VA Technology Split Core AC Current Transformer Ratio 250/5 Aperture Size 50 x 80mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 250Amp x 1.2 Termination Style Screw Unit Weight 1.25kg Factory Pack Qty 9 Datasheet Product Datasheet