Fastron FTM1-A80-V4-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 400VAC, 64 Amps @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A80-V4-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
64 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
N/A Optional
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
Fastron FTM1-A80-V2-W0, Single Phase, Phase Angle/Burst Controller for Primary Control of Transformer (Phase Angle mode only), Voltage/Current/Power Limit Modes, For Single Phase Loads, 230VAC, 64 Amps @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
Single Phase, Angle/Burst Controller
4-20mA/0-10V/0-5V input Proportional Control
Phase Angle or Burst switching
Digital Display and Controls
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTM1-A80-V2-W0
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V/POT
Load Current
64 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
230VAC +/-10%
Supply Voltage
230VAC +/-10%
Dimensions
H:260mm W:94mm D:187mm
Soft Start
N/A
Termination Style
Screw
Unit Weight
2.5kg (4kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Brochure
Video for How to Set Current/Voltage/Power limit
MTC300-36-415F3, Dual Thyristor Module, 300 Amp, 3600V, 50mm package
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
50mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC300-36-415F3
Vrrm
3600V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
300 Amp
Package Size
W:50mm L:115mm D:52mm
Itsm
7.2 kA
VF(to)
0.85V
Tj(max)
125°C
rF
0.9mΩ
I(gt) @ 25 Deg C
30-180mA
Terminals
M10 Screw
Hole Centres
38mm x 88mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.09°C/W
R th(c-h)
0.04°C/W
Weight
1260g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
8
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCC312-16io1 for Solder bonded alternative
AMB-DVO(0-15)-A, 96x48mm DC Voltmeter, Bipolar 0-15VDC Input, 240VAC supply, Large 4.1 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 4.1 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
90mm Depth
CE Approved
Specification
Alish Part Number
AMB-DVO(0-15)-A,
Conditioner Output
N/A
Input
0-15VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110-240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
4.1 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron FTCK Series Type K Thermocouples MIMS Class A, Standard Sizes and Lengths 3mm or 5mm Shaft, Braided SS/Fibreglass/Teflon Tail, 304 Stainless Steel Sheath, CE ANSI ROHS Approved, -20 to 800 Deg C
Class A Accuracy
CE, ANSI, ROHS Approved
Kink proof Fiberglass Reinforced SS Braided Cable
Low Long Term Drift
Rated for -20 to 800 Deg C Max
Spring Cable Connection
50 - 500mm or custom
Sheath Thickness 3/5/9mm or custom
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FTCK Series
Sensor Type
Type K Thermocouple
No of Wires
2
Probe Length
50-500mm or custom
Sheath Thickness
3/6/9mm or custom
Sheath Material
SS 304 Stainless Steel
Aprovals
CE, ANSI, ROHS
Accuracy
Class A
Cable length
3 Meters (Standard) or custom
Cable Type
Teflon/Fibreglass/Braided Stainless Steel
Temperature Range
-20 to 800 Deg C
Special Feature
Spring Cable Strain Relief
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
300-500g
Factory Pack Qty
1
Datasheet
Type K Datasheet
Type K 100mm Datasheet
Type K 50mm Datasheet
F930 Series Programmable True RMS AC or DC Versions, Various Ranges 100mA - 250 Amp AC/DC Current Transducer with 4 Digit LED Display, Selectable Process Level Outputs, Optional RS485 and/or 2 x Relay Outputs
Features
Following on from the success of F916,F921,F920,F922,,F923 Series AC/DC Current Transducers & Trip Modules. We designed a new microcontroller based transducer to take advantage of modern digital methods and the latest generation of LEM ASIC based current sensors. Our transducer can adjust zero, span, and optional Alarms, including dual flasher outputs in both Traditional Relay or Solid State types. Ultimately, there will also be a Power Transducer with one or two analogue outputs & RS485 Comms for import export control applications. Our Transducers are widely used in rail and several other industrial control and automation industries.
Datasheet
Product Datasheet
LEM LF 2010-S, C/L Hall Effect Sensor, 2000 Amp, +/-400mA Output, 60.5mm Aperture, +/-15..24V Supply, Panel Mount
Features
Bipolar and insulated current measurement up tp 2700 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LF 2010-S
Technology
Closed Loop Hall Effect
Aperture
ø60.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/- 3000 Amp
Output
400 mA
Isolation
6 kV
Bandwidth
DC-150 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.2%
Termination Style
Molex 6410
Unit Weight
503g
Factory Pack Quantity
9
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Enerpro LVR-31 Kit, 3 Stage, Smart Battery Charger for Locomotive/Train 78/70VDC 90 Amp
The LVR-31 replaces the older EMD 8330790 auxiliary generator constant voltage regulator. The VR-31 replaces the EMD VR-10-16 constant voltage regulator.
Enerpro’s 3-stage charging has proven to increase battery life and reduce no start events on locomotives that are repeatedly started and shut down. There are over 3,800 of the VR, DVR, and LVR variants.
3-stage charging is the industry standard method of charging lead acid storage batteries. All modern industrial chargers (fork lift, data center, etc.) use 3-stage charging. Enerpro introduced it to the locomotive market in 2010 and received a US Patent. All Progress Rail and Wabtec locomotives now come with 3-stage charging as a standard feature.
Features
100% USA Made
3 Stage, Smart Battery Charger
Kit includes the EBCS-3 current sensor
Stage 1: Constant 90 Amp Safe Initial charge
Stage 2: Constant 78 Volts Charge to 95%
Stage 3:Constant 72 Volts to maintain charge
LVR-31 Kit Includes 1 x LVR-31 Battery Charge Controller, 1 x 5.7 Ohm 750W Resistor, 1 x Feedback Current Sensor
Applications
Locomotive/ Railways battery Charger
Industrial battery chargers
Any suitable 72V battery system
Extend the life of any batteries
Specification
Enerpro Part Number
LVR-31 Kit
Rated Operating Temperature
50°C
Stage 1 Charge
4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)
Stage 2 Charge
Depends on SCR stack
Stage 3 Charge
0-100%
Special Feature
See Optional Card Sets below
Mounting Style
Panel Mount
Termination Style
Connector (see datasheet)
Unit Weight
11kg
Factory Pack Qty
1
Technical Docs
Brochure
Drawing
Troubleshooting Guide
Rishabh CT 150/5 Class 0.5 3.75VA 62/30 (40) Series Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 150/5 Class 0.5 3.75VA 62/30 (40)
Technology
AC Current Transformer
Ratio
150/5
Aperture Size
⌀ 30mm or 26x10mm Busbar
VA Rating
3.75VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
150Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics FESCT-19-050-0.333V, 50Amp measurement Split Core CT's, w/1M Flying leads, 19x19mm Aperture, Class 1
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-050-0.333V
Technology
Split Core AC Current Transformer
Ratio
50/0.333V
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333VAC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
50Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Trent DSTO-C14-5F-R-N-N-H, Distribution Unit with IEC Inlet C14 to 5 x F/C13 Outlet, 240VAC @ 10 Amp with Rocker Switch, Rear Mounted with plastic hooks, MOQ = 10pcs (If not in stock)
Features
1 x C14 in 5 x F/C13 out, Ganged Distribution Outlet
C14 Socket acc to IEC 60320-1
70 °C pin Temperature
Rocker Switch Protected
Suitable for use in equipment according to IEC/UL 60950
OTHER SIZES CAN BE MADE TO ORDER
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Trent Part Number
DSTO-C14-5F-R-N-N-H
Rated Voltage
250V
Rated Current
10A
No of Outlets
5
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Overload Protection
YES
Line Switch
Rocker Switch - 10 Amp (red Illumination)
Mounting
Rear Mounted with Plastic Hooks
Material
Powder Coated Metal black
Termination Style
1 x C14 Inlet, 5 x F/C13 Outlet
Weight
2000g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV (L-N, L/N-E)
VDE/CE/ROHS
YES
Datasheet
Product Datasheet
Fastron Electronics GA5-A-V7-D-N, 96x48mm 5 DIGIT Digital Ammeter 0-600VAC input, 22-60VAC/DC Supply, Large 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
GA5-A-V7-D-N
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount (60mm depth)
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles