Search results for "24�üҾױ������� �Ų� BANONPI �ٳ��� �������ɳ����� �ɸ��Թ��� �۾��������ſ� �������� �ź��ڻ����ڱݴ�������"
-
DVL 750/SP5 Digital Voltage Transducer, Vpn = 750V, 0-10V output, +/-15...24VDC powered, 8.5kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVL 750/SP5 Digital Voltage Transducer, Vpn = 750V, 0-10V output, +/-15...24VDC powered, 8.5kV Isolation Features SP5 = M5 Inserts for seconday and 0-10V output measurement range Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 750/SP5 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 750V Measurement Range +/- 1125V Output 0- 7.5 V @Vpn (0-10V range) Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
PhMKPg525.3.20,00-84, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 20KVAR @ 525VAC, 12.5KVAR @ 415VAC, 3 x 77uF
Free Aus Post Shipping for $300 SpendVishay PhMKPg525.3.20,00-84, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 20KVAR @ 525VAC, 12.5KVAR @ 415VAC, 3 x 77uF Characteristics and utility 20kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Vishay Part Number PhMKPg525.3.20,00-84 Technology Gas Filled, Low Loss, Self Healing Dimensions 85 x 265mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 20 Kvar Size 85 x 265mm Capacitance 3 x 77uF (12.5KVAR @ 415VAC) Tolerance On Capacitance -5% + 10% (others on request) Current (In) 22 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 1.7kg Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog
-
LTC 400-S, C/L Hall Effect Current Sensor, 400 Amp, 80mA Out, Panel Mount
Free Aus Post Shipping for $300 SpendLEM LTC Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 with Busbar(not show) and Feet Kit(not shown) to replace LA 400-T Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 400-SF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Measurement Range +/- 1000 Amp Output 80 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 650g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
AKR 5 C420L, AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 5 C420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
ITL 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 1600mA Output, 268mm Aperture, +/-24V Supply
Free Aus Post Shipping for $300 SpendITL 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 1600mA Output, 268mm Aperture, +/-24V Supply Datasheet Product Datasheet
-
DRSCN05, Slimline Relay Socket, SOCKET ONLY
Free Aus Post Shipping for $300 SpendCrydom DRSCN05, Slimline Relay Socket, SOCKET ONLY Features Output rated up to 6 Amp @ 240VAC up tpo 72VDC Control input DIN Rail Mount Ultra slim package CE Compliant to IEC 60664 IP67 Specification Crydom Part Number DRSCN05 Switching Type 250VAC 6 Amp Load SSR or Relay Approvals UL, CE ROHS Yes (Details) Control Voltage up tp 72VDC Load Current 6 Amp (rms) /6 Amp DC Special Feature LED Status Indicator Mounting Style Din Rail Mount Load Voltage Range 24VDC Load EMC Compliant Level 3 Termination Style PCB or Socket Mount Unit Weight 6g Factory Pack Qty 20 Datasheet Relay Datasheet Alternative F41F-1Z-C2-5 12-14VAC/DC Socket