Thyro-A-1A-500-16-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 160Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Advanced Energy Thyro-A-1A-500-16-H-RL3, Thyro-A-1A-Series Single Phase SCR Controller 160Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes Features Optional Profinet,Profibus,Ethernet,Modbus Comms 500VAC +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-500-16-H-RL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,218.00
$1,437.24 inclGST -
LT 1005-S/SP4, C/L Current Transducer, Ipn = 1000A, +/-15/24VDC, 250mA Output, X = 0.4%
Free Aus Post Shipping for $300 SpendLEM LT 1005-S/SP4 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 2000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 1005-S/SP4 Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/- 2000 Amp Output 250 mA Isolation 12 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.4% Termination Style M4 theaded studs Unit Weight 850g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
AT 20 B5, Split Core AC Current Transformer, Self Powered, 20 Amp, Average RMS 5V output
Free Aus Post Shipping for $300 SpendLEM AT 20 B5, Split Core AC Current Transformer, Self Powered, 20 Amp, Average RMS 5V output Compact and versatile Split Core AC current sensor, 20 Amp Average RMS 0-5V output Features Split Core True RMS output 0-5V voltage output Busbar, or Din Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications Automation Systems Analogue current reading for remote monitoring (e.g. Motor) Data Loggers Self Powered. Will not drain data logger batteries Panel Meters Simple connection displays power consumption Specification LEM Part Number AT 20 B5 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS) 20 Amp Maximum Measurement Current (RMS) 24 Amp Output 0-5V (Average) RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Aperture ⌀ 16mm Termination Style Spring Terminal Block (Female Included) Approvals CE,UL,ROHS Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet
-
LF 505-S C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, 30.2mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.6%
Free Aus Post Shipping for $300 SpendLEM LF 505-S C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, 30.2mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.6% Features Bipolar and insulated current measurement up tp 800 Amp Current output Bandwidth DC to 200kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 505-S Technology Closed Loop Hall Effect Aperture ø30.2mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 500 Amp Measurement Range +/- 800 Amp Output 100 mA Isolation 3.8 kV Bandwidth DC-200 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.6% Termination Style Molex 6410 Unit Weight 240g Factory Pack Quantity 18 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DVL 250 UI, Digital Voltage Transducer 250V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 250 UI, Digital Voltage Transducer 250V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 250 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 250V Measurement Range +/- 375V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST -
KNK3053 50KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF, Includes Discharge Resistor
Heavy Item - No Free ShippingIskra Doo KNK3053 50 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF Characteristics and utility 50kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 50 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 136 x 285mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 50 Kvar Capacitance 3 x 192.48uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 36 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 4.2kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
-
DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 125 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 125V Measurement Range +/- 187.5V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
GX34FDB, Contactor SPST-NO, 350+ AMP, 12-800VDC, 48VDC Coil, M4 Coil Terminations, SPST-NO Auxiliary Contact, IP67, IP69K
Free Aus Post Shipping for $300 SpendGigavac GX34FDB, Contactor SPST-NO, 350+ AMP, 12-800VDC, 48VDC Coil, M4 Coil Terminations, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX34FDB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 48VDC Load Current 350+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals M4 Screw Aux Contact Terminals M4 Screw Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
DVL 50 UI, Digital Voltage Transducer 50V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 50 UI, Digital Voltage Transducer 50V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 50 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 50V Measurement Range +/- 75V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST -
DFM1200EXM45-TS000, Fast Triple Diode Module, 1200 Amp, 4500V, 140mm Package
DFM1200EXM45-TS000, Fast Triple Diode Module, 1200 Amp, 4500V, 140mm Package Features Pressure Contact Technology Electrically insulated base plate Very low forward voltage drop Very low leakage current International standard package 6000V Isolation 140mm Base Width Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Filed Supply for DC Motors DC supply for PWM inverter Specification Dynex Part Number DFM1000EXM45-TS000 Vrrm 4500V Diode Configuration Fast Dual Diode Module Isolated IF(av) 1200 Amp Package Size W:140mm L:190mm D:38mm V(ISOL) 2.5V Tj(max) 150°C Terminals M8 Bolt Hole Centres 124mm x 171mm (M6) Gate Terminals N/A R th(j-c) 24°C/W R th(c-h) 6°C/W Weight 1.4kg Mounting Torque 6 Nm (12 Nm Terminals) Factory Pack Qty 2 Certification UL Listed, ROHS Dynex Headquarters UK Datasheet Product Datasheet
$2,097.00
$2,474.46 inclGST -
MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms
Free Aus Post Shipping for $300 SpendIskra Doo MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms Class 0.1 Active, Class 0.2 Reactive (EN 60688) RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number MT550-SSHFNAASS (DIN) Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 500V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.1(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations EU Style Clamp Terminals Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
-
GV142CAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 24VDC Coil, SPST-NO Aux Contacts, 38cm Flying leads, IP67, SIDE MOUNTING
Free Aus Post Shipping for $300 SpendGigavac GV142CAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 24VDC Coil, SPST-NO Aux Contacts, 38cm Flying leads, IP67, SIDE MOUNTING Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Giagavac Part Number GV142CAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 24VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature None Mounting Style Side Panel Mount (M5) Load Voltage Range 12 - 100VDC Standards CE, UL1604, IP67, SAEJ1171 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet