Schurter 4781.0100, IEC Appliance Plug C15/F, Rewirable, Black, for 3 x 1.5m sqr/14AWG Maximum wire size, 10mm Type
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet C15/F Plug acc to IEC 60320-1
Screw On Mounting
120 °C Operating Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
4781.0100
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 120°C
Mounting
Wire Screw Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
C15 Female to Screw Terminal
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
Rishabh CT 400/5 Class 1 20VA 86/40 (45), Current Transformer 400/5Amp CT 20VA, Class 1 HIGH BURDEN
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 400/5 Class 1 20VA 86/40 (45)
Technology
AC Current Transformer
Ratio
400/5
Aperture Size
36mm or 11x41mm Busbar
VA Rating
20VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Moun
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
400Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
M1 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 30V Bare copper, (or 600V insulated cables)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min) NOTE: 30V only with Non Insulated cables, see M2 for 600V Insulated types.
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M1.10.2mA,M1.100.0.1V,M1.100.100mA,M1.100.1A,M1.100.1V,
M1.200.1A,M1.200.2V,M1.UM.1A.1V,M1.UM.50A.1V,M1.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
30V (rms) Bare Copper, 600V (rms) Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
Automotive Open Loop Current Sensor for up to 48VDC Battery, +/-50 Amp and +/-400Amp Dual Outputs, Battery Drive, Vref = 2.5V output
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range, +/-50 Amp and +/-400Amp Dual Outputs
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
HSNBV-D05
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-50 Amp
Load Current Channel 2 (RMS)
+/-400 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Mounting Style
Panel Mount/Cable Mount
Termination Style
Fuse Mounting Style
Unit Weight
25g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron Electronics SCT-F16-100-1A, 1 Amp Output, 100Amp measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-100-1A
Technology
Split Core AC Current Transformer
Ratio
100/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
RC1-K0x 12-48VAC, RC Snubber Network 12-48VAC, For KNL or other Contactors
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Datasheet
RC4-K0x 380-600VAC, RC Snubber Network 380-600VAC, For KNL or other Contactors
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Datasheet
Fastron 16F-SP-NO-AL, Split Core AC Current Switch, Multirange 1-10A, 10-50A, 50-200Amp, Self Powered, 10% Accuracy, Average RMS Current Sensing, Normally Open Contacts, 0.3Amp @ 135VAC/DC Adjustable Trip
Compact and versatile current switches for detection of AC Currents, Multirange 1-10Amp, 10-50Amp, 50-200Amp via jumper
Features
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
16F-SP-NO-AL
Technology
Split Core AC Current Transformer
Alarm Type
NO Relay 0.3Amp @ 135VAC/DC
Supply Voltage
Self Powered
Load Current (RMS)
Multirange 1-10A, 10-50A, 50-200Amp
Trip Point
Adjustable
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
10% (Minimum Threshold 1.5 +/-0.2 Amp)
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Fastron Electronics SCT-F36-250-5A, 5 Amp, 250Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
5 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-250-5A
Technology
Split Core AC Current Transformer
Ratio
250/5 Amp
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
5 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
250Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Fastron Electronics AM5H-A-DV1-AR4AN, 96x48mm DC Ammeter DC Voltmeter 0-50mVDC with 4-20mA output, 4 x Relays, 100-240VAC/DC Supply, Digital Panel Meter & Transmitter, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-DV1-AR4AN
Conditioner Output
4-20mA
Alarms
4 x Hi/Low, 7 Amp @ 277VAC
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
5 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles