Search results for "텔레:bpmc55^^마운자로판매위고비건강관리"
-
SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's
Free Aus Post Shipping for $300 SpendFastron Electronics SCT-F36-500-040A, 40mA, 500Amp Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-500-040A Technology Split Core AC Current Transformer Ratio 500/40mA Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
Free Aus Post Shipping for $300 Spend$66.50
$78.47 inclGST -
1NT01L-8418, 70 Deg C, NC Thermal Switch 10 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, 90 Deg Angled Terminals
1NT01L-8418, 70 Deg C, NC Thermal Switch 20 Deg C Hysteresis, +/-2% Tolerance, Flange Mount, 90 Deg Angled Terminals Datasheet Product Datasheet
$12.00
$14.16 inclGST -
H71/110M, Heatsink for Single or Three Phase Solid State Relay, 3 x 13Amp or 1 x 35 Amp @ 50 Deg C
H71/110M, Heatsink for Single or Three Phase Solid State Relay, 3 x 13Amp or 1 x 35 Amp @ 50 Deg C MIlled for Semiconductor surface mounting T6 Hardness Rails for ease of mounting for Single or 3 phase SSR Specification Fastron Part Number H71/110M ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 3 x 13 Amp or 1 x 35 Amp (rms) @ 50 Deg C Mounting Style Panel Mount Termination Style Screw Therm Imedance (Rha) 1.76 Deg C/Watt @ 100mm Unit Weight 400g Factory Pack Qty 10 Datasheet H71 Datasheet FTH Series Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here
$49.00
$57.82 inclGST -
Multicube Modular Master with 1 Measurement Module
Free Aus Post Shipping for $300 SpendNorthern Design Multicube Modular Master with 1 Measurement Module Up to 20 Meters in 1 with additional modules Minimum 2 x 3 Phase Circuits with measurement module Master Unit of Modular Multicube System Optional 12 way pulse/alarm digital output modules Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L Graphic Display Optional RS485 or Ethernet communication up to 19,200 bit/s True RMS measurement of currents and voltages The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals. Features : 20 Meters in same space as 4 traditional meters Expandable to 20 x 3 Phase or 60 x Single Phase Circuits Accuracy class 1 In Built Logger Simple Menu Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication 5 Year Warranty 240V AC power supply Specification Northern Design Part Number Multicube Modular Master Functions kWh Meter, Energy Meter, Power Quality, Network Recorder Supply Voltage 240VAC < 15VA Nominal Measurement Range 415V L-L 240V L-N, 0.333V Maximum Measurement Range 480V L-L 280V L-N, 0.383V Display Graphic LCD Pulse Output 12 (Optional) Accuracy Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive Ethernet Optional Logger Optional Isolation 2.11kV RS232/RS485 Optional Modbus RTU RS485 2400-19200 b/s Weight 900g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material ABS with fire protection to UL94-V-O. Self extinguishing EnclosureSize 164 x 96mm x 100mm Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product brochure User manual Wiring Diagram Suitable 0.333V CT's Split Core CT's
Free Aus Post Shipping for $300 Spend$1,060.00
$1,250.80 inclGST -
SKKT27/16E, Dual Thyristor Module, 27 Amp, 1600V, Without Aux Cathode Connection
Semikron SKKT27/16E, Dual Thyristor Module, 27 Amp, 1600V, Without Aux Cathode Connection Features Thyristor for line frequency Solder - Solder Bonded Electrically insulated base plate Industrial standard package 3600V Isolation 22mm Base Width Applications Power Converter Line rectifying 50/60 Hz Controlled Rectifiers Softstart AC motor control AC power control Lighting and temperature control Specification Semikorn Part Number SKKT27/16E Vrrm 1600V Diode Configuration Dual Thyristor Module IF(av) @ 85 Deg C 27 Amp Package Size W:22mm L:93mm D:30mm TO-240AA Terminals M5 Screw Hole Centres 80mm (M6) Gate Terminals Faston A2.8 x 0.8mm Weight 110g Mounting Torque 5 Nm (3 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Country of Origin Hungary Datasheet Datasheet Alternatives See MCC16-16io1b for IXYS alternative
$55.47
$65.45 inclGST -
DE72/400VAC, 72x72mm, 0-400VAC Input Voltmeter, 500VAC Range
Rishabh DE72/400VAC, 72x72mm, 0-400VAC Input Voltmeter, 500VAC Range Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DE72-500V Nominal Measurement Range 0 - 400VAC Maximum Measurement Range 500VAC Over Range x 1.2 (600VAC) Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
$49.50
$58.41 inclGST -
RCS-1800-1600 0.333V, 3 Phase 1600Amp AC Measurement 6 Inch Rogowski Coils with Integrator, Class 1
Free Aus Post Shipping for $300 SpendRCS-1800-1600 0.333V, 3 Phase 1600Amp AC Measurement 6 Inch Rogowski Coils with Integrator, Class 1: The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Suitable Alternative to Solar Edge CTRC-07500-1600 Specification Magnelab Part Number RCS-1800-1600 Function AC Current Measurement Nominal Measurement Current (Ipn) 1600 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 1500 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 6 Inch Coil Circumference 18 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide
Free Aus Post Shipping for $300 Spend$839.00
$990.02 inclGST -
RI63N B 25, 4 Pole MCB Miniature Circuit Breaker B Curve 25 Amp, 230/400VAC
Iskra Doo RI63N B 25, 4 Pole MCB Miniature Circuit Breaker BV Curve 25 Amp, 230/400VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : < 50mS Trip Delay Time 3 Pole Disconnect 10kA Short Circuit Rating Suitable for Isolation Customised versions available Type B, C, D Curve available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 Specification Iskra Doo Part Number RI63N B 25 Functions 4 Pole MCB - C Curve Nominal Voltage 230/400VAC @ 50Hz Nominal Current Range 25 Amps RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 55 Deg C Rated Operations 10,000 Ops Insulation Voltage 500V Short Circuit Current 10kA Approvals VDE, GOST-R Standards IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ; Weight 130g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Alternatives
$45.00
$53.10 inclGST -
ESCT-TA24-250A/100mA + HY-2.0, 250A/100mA Measurement, Class 1 Split Core CT's
Eastron Europe Electronics ESCT-TA24-250A/100mA + HY-2.0, 250A/100mA Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 100mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads with HY-2.0 Connector Applications Eastron Modular Metering Equipment Energy Monitoring Load Balancing Power Quality Measurements Specification Eastron Europe Part Number ESCT-TA24-250A/100mA + HY-2.0 Technology Split Core AC Current Transformer Ratio 250/100mA Aperture Size ø 24 mm VA Rating 1VA Accuracy Class Class 1 Output 100mA (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads with HY-2.0 Connector Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide CRJ-31 Connector User Guide
$52.00
$61.36 inclGST -
0034.3117, FST 5x20mm Time Lag Fuse 1Amp, 250VAC, 10 x In, IEC 60127-2
Schurter 0034.3117, FST Glass 5x20mm Time Lag Fuse 1Amp, 250VAC, 10 x In, IEC 60127-2 Features Meets UL and IEC standards UL Recognized for 250VAC High breaking capacity of 10 x In @ 250VAC Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation Applications Electrical Appliances Power Supply Adapters Switch Mode Power Supplies Avionics In-line protection Specification Schurter Part Number 0034.3117 Fuse Type I²t Time lag Nominal Voltage 250VAC I²t Rating (Pre-Arcing) 3.3 A²/s Nominal Current (AC rms) 1 Amp Tested Breaking Capacity 10 x In @250VAC Dimensions 5 x 20mm Fuse Holder 0031-2203 Fuse Holders Mounting Style Requires fuse holder Operating Temperature Range -55°C / 125°C Watt Loss 0.2W Unit Weight 1.2g Factory Pack Qty 10 Datasheet Product Datasheet Fuse Holder 0031-2203 Shock Proof Fuse Holders
$0.60
$0.71 inclGST -
0034.3120, FST 5x20mm Time Lag Fuse 2Amp, 250VAC, 10 x In, IEC 60127-2
Schurter 0034.3120, FST Glass 5x20mm Time Lag Fuse 2.5Amp, 250VAC, 10 x In, IEC 60127-2 Features Meets UL and IEC standards UL Recognized for 250VAC High breaking capacity of 10 x In @ 250VAC Meets the requirements of IEC 60127-2 for Industrial Medical, Aviation Applications Electrical Appliances POwer Supply Adaptors Switch Mode Power Supplies Avionics In-line protection Specification Schurter Part Number 0034.3120 Fuse Type I²t Time lag Nominal Voltage 250VAC I²t Rating (Pre-Arcing) 16 A²/s Nominal Current (AC rms) 2.5 Amp Tested Breaking Capacity 10 x In @250VAC Dimensions 5 x 20mm Fuse Holder 0031-2203 Fuse Holders Mounting Style Requires fuse holder Operating Temperature Range -55°C / 125°C Watt Loss 0.3W Unit Weight 1.2g Factory Pack Qty 10 Datasheet Product Datasheet Fuse Holder 0031-2203 Shock Proof Fuse Holders
$0.48
$0.57 inclGST -
DF12, 12 Module Compact Distribution Boards, ABS/PC, Flush Mounted IP40 with Terminal Block, Neutral bar and DIN Rail
Trent DF12, 12 Module Compact Distribution Boards, Flush Mounted IP40 with Terminal Block, Neutral Bar and DIN Rail Features Latching Door/Window IP40 Protection Class RAL 7035 Double Insulation IEC 60670-1, IEC 60670-24 Installation Temperature -20 to 60 Deg C Glow Wire Test 650 Deg C 10 x PE and 10 x N Conductor Terminals Datasheet Product Datasheet
$32.00
$37.76 inclGST