Search results for "텔레@tetherzon$"
-
ITZ 2000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 2000 Amp peak, 1000mA Output, 50mm Aperture, 100-240VAC Supply
Heavy item - No Free ShippingITZ 2000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 2000 Amp peak, 1000mA Output, 50mm Aperture, 100-240VAC Supply Datasheet Product Datasheet
-
HO 25-NSM-0000, O/L Multi Range Hall Effect Current Sensor, 25 Amp, No Aperture, 5VDC Supply, Surface Mount
Free Aus Post Shipping for $300 SpendLEM HO 25-NSM-0000 Series Open Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Multirange through PCB routing Voltage output Single power supply +3.3 V Overcurrent detect 2.93 × IP N (peak value) Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Factory calibrated Dedicated parameter settings available on request Advantages Low offset drift Over-drivable Vref Creepage / clearance > 8 mm Fast response Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-1: 1997 IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 IEC 62109-1: 2010 UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HO 25-NSM/SP33-1000 Technology Open Loop Hall Effect Aperture N/A ROHS Yes Supply Voltage 3.3 VDC Load Current (RMS + DC) 25 Amp Measurement Range +/-62.5 Amp Output 1.65 Vref Isolation 4.3 kV Bandwidth DC-100 kHz Mounting Style Surface Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style PCB Surface Mount Unit Weight 34g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LTC 200-SF/SP2, C/L Hall Effect Current Sensor, 200 Amp, 200mA Out, +/-15..24VDC, Panel Mount, X = 0.5%, ø27.5mm
Free Aus Post Shipping for $300 SpendLEM LTC 200-SF/SP2, C/L Hall Effect Current Sensor, 200 Amp, 200mA Out, +/-15..24VDC, Panel Mount, X = 0.5%, ø27.5mm Features Bipolar and insulated current measurement up tp 400 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 200-SF Technology Closed Loop Hall Effect Aperture ø27.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/- 400 Amp Output 200 mA Isolation 12 kV Bandwidth DC-100 kHz Mounting Style Panel Mount (with feet) Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 300g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
LA 55-TP C/L Hall Effect Current Sensor, 50 Amp, 50mA Output, PCB Mount, No Aperture, +/-12..15V Supply, X = 0.65%
Free Aus Post Shipping for $300 SpendLEM LA 55-TP Series Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 200kHz Closed loop transducer using Hall effect Compact and versatile PCB Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA55-TP/SP1 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 50 Amp Measurement Range +/-70 Amp Output 50 mA Isolation 2.5 kV Bandwidth DC-200 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 85°C Accuracy 0.65% Termination Style Through Hole PCB Unit Weight 18g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LA 150-P/SP1 C/L Hall Effect Current Sensor, 150 Amp, 75mA Output, No Aperture, +/-12..15V Supply, PCB Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LA 150-P/SP1 Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 150kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA150-P/SP1 Technology Closed Loop Hall Effect Aperture 13 x 8mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 150 Amp Measurement Range +/-212 Amp Output 75mA Isolation 2.5 kV Bandwidth DC-150 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 35g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
LF 305-S C/L Hall Effect Current Sensor, 300 Amp, 150mA Output, 20.1mm Aperture, +/-15..24V Supply, Panel Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LF 305-S Series Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LF 305-S Technology Closed Loop Hall Effect Aperture ø20.1mm ROHS Yes Supply Voltage +/- 12 VDC to +/- 20 VDC Bipolar, Isolated Load Current (RMS + DC) 300 Amp Measurement Range +/- 500 Amp Output 150 mA Isolation 3.8 kV Bandwidth DC-100 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style Molex 5054-03/AG Unit Weight 95g Factory Pack Quantity 60 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
IN 1000-S High Precision Hall Effect Current Sensor, 1000 Amp, 1000mA Output, 38.2mm Aperture, +/-15V Supply
Free Aus Post Shipping for $300 SpendIN 1000-S High Precision Hall Effect Current Sensor, 1000 Amp, 1000mA Output, 38.2mm Aperture, +/-15V Supply Features Closed loop (compensated) current transducer using an extremely accurate zero flux detector 9-pin D-Sub male secondary connector Status signal to indicate the transducer state LED indicator confirms normal operation Metal housing to improve immunity to EMC & power dissipation Operating temperature −40 °C to 85 °C. Advantages Very high accuracy Excellent linearity Extremely low temperature drift Wide frequency bandwidth High immunity to external fields No insertion losses Very low noise on output signal Low noise feedback to primary conductor. Applications Feedback element in high performance gradient amplifiers for MRI Feedback element in high-precision, high-stability power supplies Calibration unit Energy measurement Medical equipment. Standards EN 61000-6-2: 2005 EN 61000-6-3: 2007 EN 61010-1: 2010. Application Domain Industrial Laboratory Medical. Specification Insulation coordination Parameter Symbol Unit Value Comment RMS voltage for AC insulation test, 50 Hz, 1 min UdkV 4.2 Between primary and secondary + shield Impulse withstand voltage 1.2/50 μs ÛWkV 8 Clearance (pri. - sec.) dCImm 11.5 Shortest distance through air Creepage distance (pri. - sec.) dCpmm 11.9 Shortest path along device body Comparative tracking index CTI600 Rated insulation RMS voltage UNmV 1000 Basic insulation according to IEC 61010-1 CAT III, PD2 Rated insulation RMS voltage 1000 Reinforced insulation according to IEC 61010-1 CAT II, PD2 Environmental and mechanical characteristics Parameter Symbol Unit Min Typ Max Comment Ambient operating temperature TA°C −40 85 Ambient storage temperature TS°C −40 85 Relative humidity RH% 20 80 Dimensions See drawing in page 8 Mass mkg 1.3 Electrical data At TA = 25 °C, ±UC = ±15 V DC, unless otherwise noted. Lines with a * in the comment column apply over the −40 … 85 °C ambient temperature range. Parameter Symbol Unit Min Typ Max Comment Primary continuous direct current DC IP NA −1000 1000 * Primary nominal RMS current AC IP NA −1000 1000 * Peak primary current, measuring range ÎP MA −1500 1500 * Measuring resistance RMΩ 0 1 See graph page 5 for other value Secondary current nominal IS NA −0.666 0.666 * Number of secondary turns NS1500 Resistance of secondary winding RSΩ 8 Overload capability 1)ÎPkA −5 5 @ pulse of 100 ms Supply voltage DC +UCV 14.25 15 15.75 −UC−14.25 −15 −15.75 Current consumption positive DC +ICA 0.12 @ IP = 0 1.12 Current consumption positive DC −ICA 0.07 @ IP= 0 1.07 Output RMS noise current 0 … 10 Hz 2) Inoppm 0.05 0.1 Output RMS noise current 0 … 10 kHz 2)1.5 4 Output RMS noise current 0 … 160 kHz 2)3.5 10 Output peak-to-peak noise current 2)Ino ppppm 18 34 Electrical offset current + self magnetization + effect of earth magnetic field 2) IO Eppm −10 10 * Temperature coefficient of IO E@ IP = 0 A TCIO Eppm/K −0.3 0.3 Linearity error 2)εLppm −2 1 2 −3 1 3 * Step response time to 90 % of IPN DCtrµs 1 di/dt of 100 A/μs Frequency bandwidth (±1 dB) BWkHz 230 Small-signal bandwidth, 1.5 % of IP NFrequency bandwidth (±3 dB) BWkHz 440 Start-up time tstarts 15 Notes: 1) Single pulse only, not AC. The transducer may require a few seconds to return to normal operation when autoreset system is running 2) All ppm figures refer to full-scale which corresponds to a secondary nominal RMS current. Datasheet Product Datasheet
-
HXS 20-NP Hall Effect Current Sensor, 20 Amp, 2.5V ref output, no aperture, 5V Supply, PCB Mount, X = 1%
Free Aus Post Shipping for $300 SpendLEM HXN 20-NP Series Open Loop AC/DC Hall Effect Sensor Features Open loop current transducer Voltage output Single supply +5 V Galvanic separation between primary and secondary circuit For PCB mounting No Aperture Advantages Small size and space saving Same package for wide primary current range High immunity to external interference Fast response High insulation capability Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010 Application Domain Industrial. Specification LEM Part Number HXN 20-NP Technology Open Loop Hall Effect Aperture None ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 20 Amp Measurement Range +/-60 Amp Output 2.5 Vref Isolation 3 kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 105°C Accuracy 1.35% Termination Style PCB Through Hole Unit Weight 8g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HOYS 100-S-0100, Hall Effect Current Sensor, 100 Amp, 5VDC Supply, Panel Mount, 13 x 21.5mm Aperture, X = 1%
Free Aus Post Shipping for $300 SpendLEM HOYS 100-S-0100 Series Closed Loop AC/DC Hall Effect Sensor Features Open loop multi-range current transducer Voltage output Single supply +5 V Overcurrent detect 2.93 × IPN (peak value) Galvanic separation between primary and secondary circuit Low power consumption For busbar mounting Aperture: 21.5 × 13 mm Factory calibrated ? Mating JST connector: housing PAP-05V-S contact SPHD-00xT-P0.5. Advantages Low offset drift Over-drivable Vref Creepage / clearance > 10.5 mm Fast response Low profile 2 mm pitch connector for 22 to 28 AWG wire. Applications AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box Solar inverter on DC side of the inverter (MPPT). Standards IEC 61800-2: 2015 IEC 61800-3: 2004 IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013. Application Domain Industrial. Specification LEM Part Number HOYS 100-S-0100 Technology Open Loop Hall Effect Aperture 21.5 x 13mm ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 100 Amp Measurement Range +/-250 Amp Output 2.5 Vref Isolation 5.4 kV Bandwidth DC-180 kHz Mounting Style Busbar Mount Operating Temperature Range -40°C / 105°C Accuracy 1% Termination Style JST B05B-PASK or equivalent Unit Weight 101g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
HAIS 150-P, O/L Hall Effect Current Sensor, 150 Amp, Vref 0-5V Output, PCB Mount, 15x8mm sqr, X = 1%
Free Aus Post Shipping for $300 SpendHAIS 150-P, O/L Hall Effect Current Sensor, 150 Amp, Vref 0-5V Output, PCB Mount, 15x8mm sqr, X = 1% Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 50 to 600 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Specification LEM Part Number HAIS 150-P Technology Open Loop Hall Effect Aperture 15 x 8mm Square ROHS Yes Supply Voltage 5 VDC Load Current (RMS + DC) 150 Amp Overload Capability +/- 450 Amp Output 2.5 Vref Isolation 2.5kV Bandwidth DC-50 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style PCB Unit Weight 30g Factory Pack Quantity 10 Datasheet Product Datasheet
-
LA 130-P/SP1 C/L Hall Effect Current Sensor, 130 Amp, 65mA Output, 13.5 x 10mm Aperture, +/-12..15V Supply, PCB Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LA 130-P/SP1 Closed Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 150kHz Closed loop transducer using Hall effect Compact and versatile PCB Mounted with Strain Relief Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LA130-P Technology Closed Loop Hall Effect Aperture 13.5 x 10mm ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Load Current (RMS + DC) 130 Amp Measurement Range +/-200 Amp Output 65 mA Isolation 4.3 kV Bandwidth DC-150 kHz Mounting Style PCB Mount Operating Temperature Range -10°C / 80°C Accuracy 0.5% Termination Style Through Hole PCB Unit Weight 35g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
777307, E-STOP Safety Relay 48-240VAC/DC, 2 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2P 48-240VAC/DC 2n/o
Pilz 777307, E-STOP Safety Relay 48-240VAC/DC, 2 x NO Safety Contacts, 1 x NC Auxiliary Contact, PNOZ X2P 48-240VAC/DC 2n/o Safety Relay for Monitoring E-STOP Pushbuttons, safety gates and light barriers. Safety Features: Positive guides relay outputs, 2 x NO Safety Contacts, 1 x NC Auxiliary Contact Connection options for: E-Stop Pushbutton Safety Gate limit switch Reset button Light barriers LED Indicator for; Status channel 1/2 Supply Voltage Plug In connection terminals (cage clamp terminal or screw terminal) Redundant Circuit with in built monitoring Failsafe operation in case of component failure Correct Open/Close Operation is tested automatically in each on-off cycle Specification Pilz Part Number 777307, E-STOP Safety Relay PNOZ X2P 48-240VAC/DC 2n/o Function E-Stop Relay for E-stop, Gate or Lighting Supply Voltage 48 - 240 VAC/DC Relay Outputs 2 x NO Safety Contacts, 1 x NC Auxiliary Contact maximum Relay Current Safety Contacts 6 Amp, Auxiliary Contact 4 Amp Switch on Delay 340ms Delay on Energisation 10ms Termination Style Screw Weight 250g Certification UL Factory Pack Qty 1 Application Certification In accordance with EN 60947-5-1, EN 60204-1 and VDE 0113-1 Applications 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Datasheet Product Datasheet User Manual
$617.00
$728.06 inclGST