Fastron FES521-FD-420T, Solid Core AC Current Transducer, Multirange 0-10A,20A, 50A, Self Powered, Average RMS 4-20mA Output. 1% Accuracy (FCS521-SD-420E)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 4-20mA True RMS output
Features
True RMS 4-20mA output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FD-420T
Technology
Solid Core Solid Core AC Current Transducer
Range
0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
4-20mA True RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron FES521-FD-V10,Solid Core AC Current Transducer, Solid Core Multirange 0-10A,20A, 50A, Self Powered, Average RMS 0-10V Output. 1% Accuracy (FCS521-SD-V10)
Compact and versatile current switches for detection of AC Currents, Multirange 0-10Amp, 0-20Amp, 0-50Amp via jumper, 0-10V True RMS output
Features
Average RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES521-FD-V10
Technology
Solid Core Solid Core AC Current Transducer
Range
0-10Amp, 0-20Amp, 0-50Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-10V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Fastron Electronics SCT-F24-100-33.33mA, 100Amp measurement, 33.33mA Output Split Core CT, Suitable for Porsche E-Performance Chargers
Features
Quick Release Split Core System
Cable Mount
33.33mA Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-100-33.33mA
Technology
Split Core AC Current Transformer
Ratio
100A/33.33mA
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
33.33mA Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Iskra IK40-30-24VAC/DC, 3 Pole 3 x SPST NO, Modular Contactor 440VAC 40 Amp, 24VAC/DC 40-500Hz Control Voltage, Hum Free
Features
40 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IK40-30-24VAC/DC
Switching Type
3 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC
Load Current (RMS/DC)
40 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC 40-500Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Fastron Electronics GTD-DA6-D-11, Signal Conditioner/Voltage Transducer, 4-20mA input, 22-60VAC/DC aux, Dual 4-20mA outputs
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DA6-D-11
Conditioned Output
2 x 4-20mA
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FES2151-FP-V5, Split Core AC Current Transducer, Multirange 100A, 150A, 200A, Average RMS 0-5V Output. 1% Accuracy (FCS2151-FP-V5)
Compact and versatile current switches for detection of AC Currents, Multirange 0-100Amp, 0-150Amp, 0-200Amp via jumper, 0-5V True RMS output
Features
True RMS 0-10V output
Multirange selector
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Highly accurate low current measurement down to 1Amp
High isolation between primary and secondary circuits
Easy installation
Applications
Fault Detection
Motor or Fan Protection
Application Domain
Energy and Automation
Specification
Fastron Part Number
FES2151-FP-V5
Technology
Split Core AC Current Transducer
Range
Selectable 0-100Amp, 0-150Amp, 0-200Amp via jumper
Supply Voltage
Self Powered
Load Current (RMS)
1Amp to 50 Amp
Output
0-5V Average RMS
Isolation
2kV (AC, 50Hz, 1 min)
Bandwidth
50/60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
1%
Termination Style
Screw Terminals
Unit Weight
200g
Certifications
UL E320368, CE, Rohs compliant
Datasheet
Product Datasheet
Installation Guide
Magnelab HCT-0010-025, Split Core DC Hall Effect Current Sensor, 25 Amp, +/-4V Output, Split Core 10mm Aperture, X = 1%
Features
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
Magnelab Part Number
HCT-0010-025
Technology
Split Core Open Loop Hall Effect
Aperture
ø10mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
25 Amp
Measurement Range
+/-37.5 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
Flying Lead
Unit Weight
80g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Magnelab HCT-0010-020, Split Core DC Hall Effect Current Sensor, 20 Amp, +/-4V Output, Split Core 10mm Aperture, X = 1%
Features
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
Magnelab Part Number
HCT-0010-020
Technology
Split Core Open Loop Hall Effect
Aperture
ø10mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
20 Amp
Measurement Range
+/-30 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
Flying Lead
Unit Weight
80g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Trent F170M1315 Series 690V Semiconductor I^2t (aR) Fuse Square Body DIN 43 653 Style, 63 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor Protection
Battery Fuse
Specification
Trent Part Number
F170M1315
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
1450 A^2/s
Nominal Current (RMS DC)
63 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
24W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-50 Amp DC, 4-20 mA Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-050-24-420
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-50 Amp
Response Time
< 1uS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
DCBT-100-24-10-10, Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10VDC bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
+/-10VDC analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-100-24-10-10
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-100 Amp
Response Time
< 1uS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet