Trent F170M1315 Series 690V Semiconductor I^2t (aR) Fuse Square Body DIN 43 653 Style, 63 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor Protection
Battery Fuse
Specification
Trent Part Number
F170M1315
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
1450 A^2/s
Nominal Current (RMS DC)
63 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
24W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
Trent F170M1314 Series 690V Semiconductor I^2t (aR) Fuse Square Body DIN 43 653 Style, 50 Amp, 690VAC, Panel Mount 200kA, Size 000 (78mm Hole Centers)
Features
Square Body DIN 43 653
Wide Range of I^2t
Ratings up to 400 Amp
Busbar or Standoff Mounting
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Protection of High Powered Semiconductors according to I??t
Short Circuit Protection
DC or AC Motor Protection
Battery Fuse
Specification
Trent Part Number
F170M1315
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I??t Rating (660V)
770 A^2/s
Nominal Current (RMS DC)
50 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
40 x 100 x 20mm (Size 000)
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
24W
Termination Style
M8
Unit Weight
134g
Factory Pack Qty
10
Datasheet
Product Datasheet
DCBT-100-24-10-10, Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10VDC bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
+/-10VDC analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-100-24-10-10
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-100 Amp
Response Time
< 1uS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
DCBT-200-24-10-10, Hall Effect DC Current Transducer, +/-200 Amp DC, +/-10VDC bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-200 Amp DC, +/-10VDC Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
+/-10VDC analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-200-24-10-10
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-200 Amp
Response Time
< 1uS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
DCBT-300-24-10-10, Hall Effect DC Current Transducer, +/-300 Amp DC, +/-10VDC bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-300 Amp DC, +/-10VDC Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
+/-10VDC analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-300-24-10-10
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-300 Amp
Response Time
< 1uS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Sanrex DBA200UA60, 100A, 600V Dual Diode Module, Soft Recovery
Features
Package with DCB ceramic base plate
Isolation voltage 2500 V∼
Planar glass passivated chips
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
DC Power Supply
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Sanrex Part Number
DBA200UA60
Vrrm voltage
600533V
Device Configuration
Dual Diode Module, Soft Recovery
DC Output @ 102 Deg C
100 Amp
Package Size
W:38mm L:25mm D:12mm
Itsm
700 A
VFM
1.2V
Tj(max)
150°C
rF
Not Published
Reverse Recovery Time
150nS
Terminals
M4 (1.5Nm)
Hole Centres
30mm (M4)
Gate Terminals
N/A
R th(j-c)
0.45°C/W
R th(c-h)
Not Published
Weight
30g
Isolation
2.5kV
Factory Pack Qty
5
Certification
N/A
Sanrex Headquarters
Japan
Datasheet
Product Datasheet
Magnelab HCT-0036-500, Split Core DC Hall Effect Current Sensor, 500 Amp, +/-4V Output, Split Core 36mm Aperture, X = 1%
Features
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
Magnelab Part Number
HCT-0036-500
Technology
Split Core Open Loop Hall Effect
Aperture
ø36mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/-750 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
Flying Lead
Unit Weight
400g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Secure Meters DPM48I150-2, 48mm x 96mm LCD Digital Ammeter, 0-6 Amp Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM48I150-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
0-6 Amp
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
280g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Secure Meters DPM48V150-2, 48mm x 96mm LCD Digital Voltmeter, 57.5-250VAC Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 48mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM48V150-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
57.5 - 250VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
280g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Secure Meters DPM96V360-2, 96mm x 96mm LCD Digital Voltmeter, 3 Phase 0-500VAC Input, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96V360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
100-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IP54 (IP65 Optional)
Protection Degree
IEC / EN 61010-1; IEC / EN 61010-2-0301
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Secure Meters DPM96I360-2, 96mm x 96mm LCD Digital AC Ammeter, 3 Phase 0-6 Amp CT Inputs, 0.5% Accuracy, 40 to 300VAC/DC Supply, IP54 (Optional IP65)
Features
LCD Dual Display
250mS Response Time
PC 94 UL V0
Each unit needs just 96 x 96mm Panel Space
52mm Depth
CE Approved
ROHS and REACH
Specification
Secure Part Number
DPM96I360-2
Frequency Range
45-65 Hz
Accuracy
0.5%
Input
0-6 Amp 3 Phase CT inputs
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
40-300VAC/DC
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Standards
IEC / EN 61010-1; IEC / EN 61010-2-030
Protection Degree
IP54 (IP65 Optional)
Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Manual
DPM Series User Manual
Application Notes
Panel Meters Blog Articles
Crydom CN240A24, Slimline Relay, 15-30VDC Coil, 2 Amp 24-280VAC Load
Features
Output 2Amp @ 250VAC
15-30VDC Control input
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
CN240A24
Switching Type
250VAC 2 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
2 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
250VAC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket