Search results for "�������������� �νν������� SSSREO �Ť�H���� ��ǰ���氨�� ƯSA���ø�ī ���۱��ְ�����Ƽ �̷��� ���ø�ī �����"
-
NX1-11, Temp Controller, 48x24mm, 100-240VAC, Multirange Input, Multirange SSR/4-20mA Heating Output, Relay Cooling Output, Setup for Relay Heating Output, 1 Alarm
NX1-11, Temp Controller, 48x24mm, 100-240VAC, Multirange Input, Multirange SSR/4-20mA Heating Output, Relay Cooling Output, Setup for Relay Heating Output, 1 Alarm Multirange Dual Output and Input, User Selectable Multirange Output (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number NX1-11 Control Output 1 (Heat) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4), or 4-20mA, or SSR (12VDC, 30mA 600 Ohm) Control Output 2 (Cool) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet NX Series Brochure NX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$269.00
$317.42 inclGST -
GV241FAX, Contactor SPST-NO, 400+ AMP, 100-800VDC, 48VDC Coil, 38cm Flying leads, IP67
Free Aus Post Shipping for $300 SpendGigavac GV241BAX, Contactor SPST-NO, 400+ AMP, 100-800VDC, 48VDC Coil, 38cm Flying leads, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV241FAX Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 48VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 100 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
-
DE72/100/5A, Moving Iron Ammeter, 100/5A, 72 × 72mm, Class 1.5
Free Aus Post Shipping for $300 SpendRishabh DE72/100/1A Moving Coil Ammeter Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DE72/100/5A Nominal Measurement Range 0 - 100 Amp AC Maximum Measurement Range 100 Amp Over Range Isn x 2 (10 Amp) Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
-
DHR 100 C5, Hall Effect Current Sensor, 100Amp RMS ,5V output, 32mm aperture
Free Aus Post Shipping for $300 SpendLEM DHR 100 C5, Hall Effect Current Sensor, 100Amp RMS ,5V output, 32mm aperture Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features VFD and SCR waveforms current measurement True RMS output 4-20mA current output Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀32mm High isolation between primary and secondary circuits Easy installation Applications -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement -Application Domain Energy and Automation Specification LEM Part Number DHR 100 C5 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Load Current (RMS + DC) 100 Amp Output 0-5V Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy Level 3 Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 260g Factory Pack Qty 6 Datasheet Product Datasheet
-
LV 100-3500, C/L Voltage Transducer, 3500V, +/-15VDC Aux, 50mA Output
Free Aus Post Shipping for $300 SpendLEM LV 100-3500 C/L Voltage Transducer, 3500V, +/-15VDC Aux, 50mA Output Features Bipolar and insulated voltage measurement up tp 5250VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-3500 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 3500V Measurement Range +/- 5250 V Output 50 mA Isolation 9 kV Response 190uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet
-
Rish Xmer 62-R 100/5 Class 0.2, 1.5VA, 22mm Aperture
Free Aus Post Shipping for $300 SpendRishabh Rish Xmer 62-R 100/5 Series Class 0.2 Current Transformer Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 62-R 100/5 Class 0.2 Technology AC Current Transformer Ratio 100/5 Aperture Size ⌀ 22mm VA Rating 1.5VA Accuracy Class Class 0.2 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
-
BC-350R-100-063, Pt100 Thermometer 0 to 100 Deg C 1/2" BSP
Free Aus Post Shipping for $300 SpendTel-Tru Thermometer Range: 0…100°C Stem length: 2.5"/63.5mm Process connection: 1/2" BSP Part no: 533.39170276
-
VX4-UCMA-A1, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, 4-20mA Output, Relay Cooling 1 Alarm
VX4-UCMA-A1, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, 4-20mA Output, Relay Cooling 1 Alarm Multirange Input (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number VX4-UCMA-A1 Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals. Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 N/A Option 2 Cooling Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Mounting Style 48 x 48mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet VX Series Brochure VX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$245.00
$289.10 inclGST -
LV 100-2000, C/L Voltage Transducer, 2000V, +/-15VDC Aux, 50mA Output
Free Aus Post Shipping for $300 SpendLEM LV100-2000 C/L Voltage Transducer, 2000V, +/-15VDC Aux, 50mA Output Features Bipolar and insulated voltage measurement up tp 3000VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-2000 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 2000V Measurement Range +/- 3000 Amp Output 50 mA Isolation 6 kV Response 150uS Mounting Style Panel Mount Operating Temperature Range -10°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet
-
Xmer CT Split 105/50SC 100/5 Class 1 1.5VA, 43 x 55mm Aperture
Free Aus Post Shipping for $300 SpendXmer CT Split 105/50SC 100/5 Class 1 1.5VA, 43 x 55mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Xmer CT Split 105/50SC 100/5 Class 1 1.5VA Technology Split Core AC Current Transformer Ratio 150/5 Aperture Size 43 x 55mm VA Rating 1.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 150Amp x 1.2 Termination Style Screw Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet
-
MCT 100/5 Class 0.5 2.5VA 50-21 (30), Series Current Transformer, Revenue Grade
Free Aus Post Shipping for $300 SpendSecure MCT 100/5 Class 0.5 2.5VA 50-21 (30), Series Current Transformer, Series Current Transformer, Revenue Grade Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Secure Part Number MCT 100/5 Class 0.5 2.5VA 50-21 (30) Technology AC Current Transformer Ratio 100/5 Aperture Size ⌀ 21mm or 20x10mm Busbar VA Rating 1.5VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Certifications CE / ILAC Certified for Billing Unit Weight 300g Factory Pack Qty 9 Datasheet Product Datasheet
-
CTC0130 (clamps) - 3pcs of 100 Amp Current Clamps for NP40 Power Quality Analyser
Free Aus Post Shipping for $300 Spend100 Amp Current Clamps for use with Lumel NP40 Power Quality Analyser