Vishay VSKH91/14 Thyristor Diode Module
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKH91/14
Vrrm
1400V
Diode Configuration
Thyristor Diode Module
IF(av) @ 85 Deg C
95 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2 kA
VF(to)
0.97V
Tj(max)
125°C
rF
2.76mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
95g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See MCD95-16 for IXYS Solder Contact
See TD120N16SOF or TD122N22KOF Infineon Alternative
Vishay VSKT91/14, Dual Thyristor Module, 91 Amp, 1400V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKT91/14
Vrrm
1400V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
95 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2.0 kA
VF(to)
1.1V
Tj(max)
125°C
rF
2.38mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See TT92N16K or TT104N14K for Infineon Pressure Contact Alternative, or for IXYS solder bonded Alternative MCC95-16
Iskra Doo MT440-SSUDAAMAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 3 Programmable Analogue Outputs, 1 relay output, RS485 + USB Comms
Class 0.5 (EN 60688)
USB Comms as standard
Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics
Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N
Adjustable tariff clock, display of electric energy consumption in optional currency
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
Certified ship version available
The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.).
Accuracy class 0.5
32 Adjustable Alarms
Input frequency 50/60 Hz or 400 Hz
RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard
MODBUS RTU communication protocol
Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs)
Universal Supply 24-300VDC or 40-276VAC
Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V
User-friendly PC MiQen software
Specification
Iskra Doo Part Number
MT440-SSUSAAMAA
Functions
3 Phase Power Transducer
Supply Voltage
24-300VDC or 40-276VAC
Nominal Measurement Range
600V L-N, 1/5/10 Amp
Maximum Measurement Range
600V L-N, 12.5 Amp
Alarm
1 x Relay Output
Tariff Input
N/A
Output
3 x Analogue
Accuracy
Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Comms
USB (standard) RS485 2400-115200 b/s (RS232 Optional)
Weight
370g
Enclosure Material
UL94,
Factory Pack Qty
1
EU Directives
EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP20
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
MiQen Setting Software
MIPACK Programmer
Rishabh Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z, AC Current Transducer, Input Programmable True RMS 50Hz, 1A-5A Full Scale, 4-20mA, 60-300VAC/DC Supply, with display
Digital output setting 0-20mA/4-20mA/0-10V
Dual output version available
300mS response time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space
Specification
Rishabh Part Number
Rish Con-I(5A)-F-H-O1A1-O200-D-Z-Z
Measurement Output
4-20mA/0-20mA/0-10V User Selectable
Input
1 - 5 Amp 50/60Hz
Overlaod (Continuous)
120%
Overload (1 second)
150%
Operating Temperature
-40 - 70°C
Supply Voltage
60 - 300VAC
Accuracy
0.2%
Response Time
300mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
IP40/IP20 EN60529 Protection Class II EN61010
Weight
400g
Factory Pack Qty
1
Datasheet
Product Datasheet
Technical Support
Rish Con P setup procedure blog
Schurter DLH-22-0001 Choke
Features
Linear choke
THT-terminals
Inductor vertically positioned in housing
Applications
Smoothing RFI suppression choke
RFI suppression choke
Chopper amplifiers
DC drives and stepper motor controls
Switching power supplies
Specification
Schurter Part Number
DLH-22-0001
Rated Voltage
600V
Rated Current
0.45A
Inductance
5mH
Operating Temperature
-25°C to 125°C
Resistance
2600mΩ
Resonant Frequency
0.2 MHz
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
14g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Application Notes
Schurter 4304.5029 (FKID2-50-4/M80-A), IEC Appliance Inlet C14/M with 2-Stage EMC (RFI) Line Filter
Features
Panel Mount : Screw-on mounting from front side
4 Functions : Appliance Inlet Protection class I, EMC Filter 2 Stage High Attenuation, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole
Line filter in standard and medical version
Quick connect terminals 6.3 x 0.8 mm
Characteristics
Compact design with optimal shielding
All single elements are already wired
Plug removal necessary for fuse-link replacement
2-stage line filter with increased attenuation
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Medical Version
M80
Specification
Schurter Part Number
4304-5029 (FKID2-50-4/M80-A)
Rated Voltage
250V
Rated Current
4A
Filter Stages
2 Stage Higher Attenuation
Operating Temperature
-25°C to 85°C
Filter Type
Differential and Common Mode
Fuse Holder
2 Pole
Line Switch
2 Pole
Mounting
Panel Mount - Case 50
Material
Nickel Plated Steel
Termination Style
C14 Male to Quick Connects
Weight
260g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Timonta 5500-2001 (FPP2-25-1/A), 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter for PCB Mounting
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Specification
Schurter Part Number
5500-2001
Rated Voltage
250V
Rated Current
1A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Standard Attenuation
Leakage Current
0.25mA
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
Solder Pin
Weight
27g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2002 (FPP2-25-2/A), 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter for PCB Mounting
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Specification
Schurter Part Number
5500-2002
Rated Voltage
250V
Rated Current
2A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Standard Attenuation
Leakage Current
0.25mA
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
Solder Pin
Weight
27g
Factory Pack Qty
1
Protection Class
From front side IP 40 acc. to IEC 60529
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 5500-2053, 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2053
Rated Voltage
250V
Rated Current
3A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.25mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter IL-10-0003 (IL5-10-2), Pulse Transformer
Features
High insulation rating (>2.2 kVAC) between the primary and the secondary windings
Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics
Cost optimized design
The defined partial discharge voltage guarantees an effectively unlimited serviceable live
Applications
Galvanic separation of drive and power-circuit
Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's
DC/DC converters
Line coupling transformers in high speed data transmission
Specification
Schurter Part Number
IL-10-0003 (IL5-10-2)
Rated Voltage
380V
Rated Current (Iz)
250mA
Inductance
1.5mH
Transformer Ratio
1:1:1
Rated Power (Pm)
0.5W
Resistance (RL)
2 x 40mΩ
Rise Time (Tr)
1uS
Operating Temperature
-25°C to 125°C
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
14g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
3.5kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Application Notes
Schurter IL-20-0001 (IL5-20-2), Pulse Transformer
Features
High insulation rating (>2.2 kVAC) between the primary and the secondary windings
Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics
Cost optimized design
The defined partial discharge voltage guarantees an effectively unlimited serviceable live
Applications
Galvanic separation of drive and power-circuit
Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's
DC/DC converters
Line coupling transformers in high speed data transmission
Specification
Schurter Part Number
IL-20-0001 (IL5-20-2)
Rated Voltage
380V
Rated Current (Iz)
250mA
Inductance
3mH
Transformer Ratio
1:1:1
Rated Power (Pm)
1.1W
Resistance (RL)
2 x 40Ω
Rise Time (Tr)
1.5uS
Operating Temperature
-25°C to 125°C
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
14g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
3.5kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Application Notes