Eastron SDM630MCT-MODBUS-MID-CL0.5 V2, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 0.5S, 1/5Amp Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved
1/5 Amp CT Input
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 0.5S
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Part Number
SDM630MCT-MODBUS-MID-CL0.5 V2
Functions
Three Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 1/5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 1/5 Amp
Nominal CT Current Input
1/5Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 0.5 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Setup Video - CT Ratio Unlock
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Eastron SDM630MCT-MV, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 0.333V CT Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, SAA Approved
0.333V CT Input
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630MCT-MV
Functions
Three Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
415V L-L 230V L-N, 1/5 Amp +/-15%
Maximum Measurement Range
480V L-L 230V L-N, 1/5 Amp
Nominal CT Current Input
0.333V
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III, CE, SAA220473
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Setup Video - CT Ratio Unlock
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Eastron Europe SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516
Fast CPU for 100ms Communication response time For Solaxx or Growatt Inverters.
Can be used for any 100 Amp Direct Connect application
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
SAA Approved
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM230Modbus-MID-V2 (SLX)
Functions
Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
230V L-N 230V L-N, 100 Amp
Maximum Measurement Range
276 L-N 230V L-N,100 Amp
Nominal Current Input
Direct connect 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (100ms Response)
Weight
250g
Certification
EN 61010-1 Installation Category III, SAA212516
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Iskra IKD225-20-24VAC/DC, Two Pole 2 x NO Modular Contactor 240VAC 25 Amp, 24VAC/DC Control Voltage, Hum Free with Manual Overide
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD225-20-24VAC/DC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC
Load Rating
25 Amp
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
240VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Iskra IK63-40-230VAC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 63 Amp, 230VAC/220VDC 40-500Hz Control Voltage, Hum Free, Can Replace MC-63-240-4NO
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IK63-40-230VAC
Switching Type
4 x SPST NO
Approvals
CE
Coil Voltage
230VAC/220VDC, 40-500Hz
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC, 40-500Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Iskra IKD25-40-R-230VAC, Iskra 4 Pole 4 x SPST NO Modular Contactor 440VAC 25 Amp, 240VAC Control Voltage, Hum Free with Manual Override, Can Replace MC-25-240-R-4NO
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD25-40-R-230VAC
Switching Type
4 x SPST NO
Approvals
CE
Coil Voltage
230/240VAC/220VDC
Load Rating
25 Amp
Special Feature
Hum Free, Manual Override
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Iskra IKD25-22-R-230VAC, Iskra 4 Pole 2 x SPST NO, Configuration_2 x SPST (2 x NC), Modular Contactor 440VAC 25 Amp, 240VAC Control Voltage, 40-500Hz, Hum Free with Manual Overide, Can Replace MC-25-240-R-2NO2NC
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD25-22-R-230VAC
Switching Type
2 x SPST NO, Configuration_2 x SPST (2 x NC)
Approvals
CE
Coil Voltage
230/240VAC/220VDC
Load Rating
25 Amp
Special Feature
Hum Free, Manual Overide
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
ISPRO C 120/275 (3+0),Class II / Type 2 / C, Modular Surge Protection Device (SPD) 3 Pole 40kA,275VAC, DIN Rail Mount. For Sub Distribution Boards
Specifications
Iskra Doo part number
ISPRO C 120/275 (3+0)
Nominal Voltage
275VAC
No of Poles
3 (via 3 modules)
Category IEC / EN / VDE
Class II / Type 2 / C
Location of use
Sub Distribution Boards
Additional Remote Contacts
NO
Protection modes
L/N-PE
Protective element
MOV + GDT
Surge discharge rating
Imax up to 40 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Iskra IK63-40-24VAC/DC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 63 Amp, 24VAC/DC 40-500Hz Control Voltage, Hum Free
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IK63-40-24VAC/DC
Switching Type
4 x SPST NO
Approvals
CE
Coil Voltage
24VAC/DC, 40-500Hz
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC, 40-500Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Iskra IKD232-20-R-230VAC, Iskra Two Pole 2 x SPST NO Modular Contactor 240VAC 32 Amp, 230VAC Control Voltage, 40-500Hz, Hum Free
Features
25 Amp (rms) @ 240VAC
DIN Rail Mount
Changeover Contact
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IKD232-20-R-230VAC
Switching Type
2 x SPST NO
Approvals
CE
Coil Voltage
230/240VAC/220VDC
Load Rating
32 Amp
Special Feature
Hum Free, Manual Overide
Mounting Style
DIN Rail Mount
Load Voltage Range
240VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Contactor Datasheet
Iskra Module ISPRO C 40/275, Replacement Cartridge for Surge Protection Device (SPD) 1 Pole 40kA, 275VAC, Class II / Type 2 / C
Specifications
Iskra Doo part number
786.600.196.000
Nominal Voltage
275VAC
No of Poles
1
Category IEC / EN / VDE
Class II / Type 2 / C
Location of use
In ISPRO Products
Protection modes
L/N-PE
Protective element
MOV + GDT
Surge discharge rating
Imax up to 40 kA
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet