Search results for "tg@bitcoinsyri~~블랙테더코인전송이더리움구매"
-
Thyro-A-3A-500-100-H3, Three Phase SCR Controller 100 Amp 500VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-500-100-H3, Three Phase SCR Controller 100 Amp 500VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 500VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-500-100-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$4,419.80
$5,215.36 inclGST -
CTBR470, Square Style Core Balanced Toroidal CT's, 160x470mm Internal Diameter
Hobut CTBR470, Square Style Core Balanced Toroidal CT's (CBCT), 160x470mm Internal Diameter Features Very low differential current measurement Applications Earth Leakage Specification Hobut Part Number CTBR470 Technology Core balanced (CBCT) Aperture Size CTBR470->160x470mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide
$992.00
$1,170.56 inclGST -
Thyro S 3S Series Three Phase SCR Controller 16 - 1500Amp 400VAC +10/-15%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes
Advanced Energy Thyro S 3S Series Three Phase SCR Power Controller, 16-1500Amp, 400VAC, Phase(VAR), Burst(TAKT), SWITCH Operating Modes. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 3S 400VAC or Thyro S 3S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,154.91 - $10,967.22
-
Thyro-A-3A-400-60-H-RL3, Three Phase SCR Controller 60 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Advanced Energy Thyro-A-3A-400-60-H-RL3, Three Phase SCR Controller 60 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-60-H-RL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$4,291.10
$5,063.50 inclGST -
Thyro-A-3A-500-100-H-RLP3, Three Phase SCR Controller 100 Amp 500VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options
Advanced Energy Thyro-A-3A-500-100-H-RLP3, Three Phase SCR Controller 100 Amp 500VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback, Power Limit Options Features 500VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-500-100-H-RLP3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$5,435.10
$6,413.42 inclGST -
B514F-2T,Single Phase Half Controlled Rectifier Bridge, 25 Amp, 480VAC Line
Free Aus Post Shipping for $300 SpendCrydom B514F-2T,Single Phase Half Controlled Rectifier Bridge, 25 Amp, 480VAC Line Features For AC or DC Variable Voltage Output Up to 15KW Electrically insulated base plate Industrial standard package 2500V Isolation UL Recognized E72445 Applications Power Supplies Rectifier for drives applications Rectifiers for UPS Battery Chargers Spec Crydom Part Number B514F-2T AC Line voltage 480V Device Configuration Single Phase Half Controlled Rectifier Bridge DC Output @ 85 Deg C 25 Amp Package Size W:31.7mm L:63.5mm D:19.7mm Itsm 250 A VF 1.65V Tj(max) 125°C rF Not Published Terminals Faston (6.3mm) Hole Centres 48.2mm (M5) Gate Terminals Faston (6.3mm) R th(j-c) 0.9°C/W R th(c-h) Not Published Weight 42.5g Isolation 2.5kV Factory Pack Qty 20 Certification UL Listed Crydom Headquarters United States Datasheet Product Datasheet Alternatives See B614F-2T or PSD51/18 for higher rated equivalent App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Thyro S 1S Series Single Phase SCR Controller 16 - 1500Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Advanced Energy Thyro S 1S Series Single Phase SCR Power Controller, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), SWITCH Operating Modes. Compatible Replacement for Erutotherm Features Optional Profinet,Profibus,Ethernet,Modbus Comms 500VAC +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 1S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$932.50 - $2,882.00
-
RX4L-U-D-D-2-96-N-N-N-N-N-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms
RX4L-U-D-D-2-96-N-N-N-N-N-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms Mutirange Input 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 70 mm depth panel space EC Compliant Specification Fastron Part Number RX4L-U-D-D-2-96-N-N-N-N-N-N Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) 4-20mA Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 N/A Mounting Style 96x96mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 450g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet RX4L Series Instruction Manual
$295.00
$348.10 inclGST -
Thyro-A-3A-400-350-HF-RL3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Advanced Energy Thyro-A-3A-400-350-HF-RL3, Three Phase SCR Controller 350 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-350-HF-RL3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$8,964.45
$10,578.05 inclGST -
D06D100, 3-32VDC Input, 1-48VDC Load, 100Amp DC Output Solid State Relay
Crydom D06D100, 3-32VDC Input, 1-48VDC Load, 100Amp DC Output Solid State Relay Features Ratings from 7A to 100 Amp @ 1-48VDCVDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D06D100 Switching Type DC Load ROHS Yes (Details) Control Voltage 3.5-32VDC Load Current 100 Amp DC Surge Capability (10ms) 1200 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 1 - 48VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 85g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$304.00
$358.72 inclGST -
Thyro-A-3A-400-170-H3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only
Advanced Energy Thyro-A-3A-400-170-H3, Three Phase SCR Controller 170 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control only Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustments Synchronisation Function for Multiple TAKT Sync Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (VAR Mode Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-3A-400-170-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Three Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-57% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$6,112.70
$7,212.99 inclGST -
RX4L-U-D-N-2-96-A-N-N-N-W-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms, 2 x SV Input, Retransmisison Output
RX4L-U-D-N-2-96-A-N-N-N-W-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms, 2 x SV Input, Retransmisison Output Mutirange Input 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 70 mm depth panel space EC Compliant Specification Fastron Part Number RX4L-U-D-N-2-96-A-N-N-N-W-N Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) N/A Input Multirange (refer to datasheet) Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 4-20mA PV Retransmission, 2 x SV (Setpoint) Mounting Style 96x96mm Panel Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 450g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet RX4L Series Instruction Manual
$245.00
$289.10 inclGST