Keysolu KS32 24-24Z2 & F41F-1Z-C2-1, Slim Solid State Relay & Socket with Screw Terminals 230VAC Input, 2 Amp @ 240VAC
Features
Multirange input 12-24VAC/DC Nominal
Load Rating 6 Amp @ 30VDC/250VAC
DIN Rail Mount
Ultra slim package
UL Listed (Keysolu make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
KS32/60-24Z2 & F41F-1Z-C2-4
Switching Type
240VAC
Control Input
230VAC+/-15%
Current @ Rated Voltage
2 Amp
Contact Arrangement
1 x Slim SSR SPST
Approvals
UL,CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Control Input Power
25mA
Relay Type
Keysolu KS32 24-24Z2
Termination Style
Screw Terminals
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Relay Base Datasheet
Relay Datasheet
Trent NBR-CH14/UQ/20A/690V, gR Semiconductor Fuse, 20 Amp, 51x14mm 690V Semiconductor I²t Fuse Cartridge Style 51 x 14mm
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 125 Amp
Quick Release with RT18-63L fuse holder
DIN Rail Mount with RT18-63L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-CH14/UQ/40A/690V
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
180 A²/s
Nominal Current (RMS + DC)
20 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
51 x 14mm
Fuse Holder
RT18-63L
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
RT18-63L
Keysolu KS32/24-48D3N & F41F-1Z-C4-1, Slim Solid State Relay & Socket with Spring Terminals 24VDC Input, 4 Amp @ 48VDC
Features
Multirange input 12-24VAC/DC Nominal
Load Rating 6 Amp @ 30VDC/250VAC
DIN Rail Mount
Ultra slim package
UL Listed (Hongfa make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
KS32/24-48D3N & F41F-1Z-C4-1
Switching Type
240VAC
Control Input
24VDC+/-10%
Current @ Rated Voltage
3 Amp
Contact Arrangement
1 SPST
Approvals
UL,CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Control Input Power
25mA
Relay Type
Keysolu KS32 24-24Z2
Termination Style
Spring Terminals
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Relay Base Datasheet
Relay Datasheet
Keysolu KS32/24-48D3N & F41F-1Z-C2-1, Slim Solid State Relay & Socket with Screw Terminals 24VDC Input, 4 Amp @ 48VDC
Features
Multirange input 12-24VAC/DC Nominal
Load Rating 6 Amp @ 30VDC/250VAC
DIN Rail Mount
Ultra slim package
UL Listed (Keysolu make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
KS32/24-48D3N & F41F-1Z-C2-1
Switching Type
240VAC
Control Input
24VDC+/-10%
Current @ Rated Voltage
3 Amp
Contact Arrangement
1 SPST
Approvals
UL,CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Control Input Power
25mA
Relay Type
Keysolu KS32 24-24Z2
Termination Style
Spring Terminals
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Relay Base Datasheet
Relay Datasheet
Trent NBR Series NBR-FR22GR69V25T + RT18-125L, 25 Amp 690V Semiconductor I²t Fuse & DIN Rail Fuse Holder Cartridge Style
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 125 Amp
Quick Release with RT18-125L fuse holder
DIN Rail Mount with RT18-125L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FR22GR69V25T + RT18-125L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
410 A²/s
Nominal Current (RMS + DC)
25 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
123 x 76 x 37.5mm
Fuse Holder
RT18-125L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
13.8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
RT18-125L
Datasheet
Mersen T331079 Fuse Holder Cylindrical Series 690V Semiconductor I²t Fuse Cartridge Style 22 x 58mm
Features
Cylindrical Standard Fuses Sizes
Finger Safe
IP 20 Protection
Optional Fuse Indicator
DIN Rail Mount
Modular
Lockable
IEC Standard 60269.2 AND 3
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Mersen Part Number
T331079
Fuse Holder Type
IEC Fuse Holder
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
N/A
Nominal Current (RMS + DC)
125 Amp (90 continuous)
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
123 x 76 x 35.5mm
Fuse Compatibility
To suit 22 x 58mm cylindrical fuse
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
N/A
DC Breaking Capacity
50kA
Unit Weight
70g
Factory Pack Qty
10
Datasheet
Original Mersen Datasheet
Compatible Fuses
Equivalent to Mersen T331079
nbr-fr22gr69v25t
nbr-fr22gr69v40t
nbr-fr22gr69v63t
nbr-fr22gr69v80t
nbr-fr22gr69v125t
Trent NBR-FR22GR69V90T + RT18-125L Series 90 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 90 Amp
Quick Release with RT18-125L fuse holder
DIN Rail Mount with RT18-125L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FR22GR69V90T + RT18-125L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
7500 A²/s
Nominal Current (RMS + DC)
90 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
123 x 76 x 37.5mm
Fuse Holder
RT18-125L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
22.8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
RT18-125L
Datasheet
Trent NBR-FR22GR69V32T + RT18-125L Series 32 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 32 Amp
Quick Release with RT18-125L fuse holder
DIN Rail Mount with RT18-125L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FR22GR69V32T + RT18-125L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
605 A²/s/s
Nominal Current (RMS + DC)
32 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
123 x 76 x 37.5mm
Fuse Holder
RT18-125L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
22.8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
RT18-125L
Datasheet
Dynex DCR3060V24, Thyristor(SCR) 2320 Amp, 2400V 111/26, w/ 400mm Hard Soldered Gate Leads
Features
Very low forward voltage drop
Very low leakage current
International standard package
111/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Dynex IXYS Part Number
DCR3060V24
Vrrm
2400V
Diode Configuration
Thyristor Capsule (PUK)
IF(av) @ 85 Deg C
2320 Amp
Package Size
ø111 x 26mm
Itsm
45 kA
VF(to)
0.9V
Tj(max)
125°C
rF
0.137mΩ
Gate Terminals
Hard wired Gate leads
R th(j-c) (double sided cooled 180°sin)
0.01°C/W
R th(c-h) (double sided cooled)
0.003°C/W
Weight
1.2kg
Clamping Force
50 - 62kN
Factory Pack Qty
12
Certification
ROHS
Dynex Headquarters
UK
Datasheet
Product Datasheet
Alternatives
N3533ZC220
Dynex 2022 Shorform Catalogue
Heatsink
Heatsink Profiles
Fastron DTC1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, Multirange TC/RTD/4-20mA, 85-265VAC, 4-20mA output
Filter Time Constant Function
Converter function
2 Input 1 Output, and 1 Input Two Output Versions available
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-A/M-TR
Transmitter Output
4-20mA
Input
Multirange RTD/K/J/R/S/B/E/T/4-20mA/N/W1/W2
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
None
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual
Advanced Energy Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor, Burst(TAKT)Firing Mode Only. Compatible Replacement for Eurotherm
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, 2 Leg Economical Burst Controller Firing Mode
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustment
Synchronisation Function
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro S 2S 400VAC
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
2 Leg Burst(TAKT) for low dissipation
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installtion Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Advanced Energy Thyro-A-3A-400-130-H-RL3, Three Phase SCR Controller 130 Amp 400VAC +10/-57%, Phase(VAR), Burst(TAKT) Fire, SWITCH Operating Modes, Voltage Control, Current Feedback Option
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-3A-400-130-H-RL3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Three Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-57% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide