LEM AI-P1A Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), 1 Amp Output, Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount
The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional
Input signal
1 Amp output for Power Quality Measurements up to the 32nd Harmonic (1600Hz)
Accuracy Class 0.5 (IEC 61869-2) [1].
Linearity error ? 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature ?25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 0.5 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply.
24VDC Power Supply Meanwell HDR-30-24
Specification
LEM Part Number
AI-P1A
Function
Integrator and True RMS Conditioner for Rogowski Coils
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
1 Amp AC
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
0.5% from 25 to 5000 Amp
Current Consumption
350mA (max)
Dimensions
100mm x 78mm x 15mm
Mounting
Din Rail Mount
Integrator to Meter cable
User Supplied Shielded cable 6mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
Product Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
LEM ART-B22-D70-SP3 + AI-P1A, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner
The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
1 Amp instantaneous output.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Included Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
AI-P1A + ART-B22-D70 (3Pcs)
Function
3 Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
1 Amp output
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
3M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-P1A Datasheet
ART Series Datasheet
Applicaton Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Fastron FDV-1000-420-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-1000-420-24
Analogue Output
4-20mA
Input
0 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-AVO(-4V,+4V)D-1, Signal Isolator/Conditioner, -4V to +4V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AVO(-4V,+4V)D-1
Control Output
4-20mA Average RMS
Input
-4V to +4V AC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GTD-MVO(-4V,+4V)D-1, Signal Isolator/Conditioner, -4V to +4V AC input, 22-60VAC/DC aux, 4-20mA True RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-MVO(-4V,+4V)D-1
Control Output
4-20mA True RMS
Input
-4V to +4V AC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Magnelab DCT-0010-050, AC CT, Self Powered, 50 Amp Average RMS 0-5V output
Features
Split Core
0-5V Average RMS Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀ 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
DCT-0010-050
Technology
AC Current Transformer
Supply Voltage
Self Powered
Load Current (RMS)
50 Amp
Maximum Measurement Current (RMS)
75 Amp
Output
0-5V (Average RMS) 5% Ripple
Response Time
300ms
Isolation
2.5kV (AC, 50Hz, 1 min)
Voltage Rating
Cat III 600VAC
Bandwidth
50/60Hz
Mounting Style
Cable Mount
Operating Temperature Range
-20°C / 50°C
Accuracy
2%
Aperture
⌀ 10mm
Termination Style
Screw
Approvals
CE,UL,ROHS2
Unit Weight
70g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron Electronics GBMA-4-DA6-ANNY, 140x420mm Digital Ammeter, Panel Mount, 4-20mA Input, 100-240VAC/VDC supply, with IR Remote Control, RS485 Modbus RTU
Adjustable Zero and Span Setting
Adjustable Display Scaling
Remote Control Included
Wall Mount
LED Tile Display
Large 4 Digit 100mm (40 Inch) LED Display
250mS Response Time
PC 94 UL V0
100mm Depth
CE Approved
Specification
Fastron Electronics Part Number
GBMA-4-DA6-ANNY
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Comms
RS485 Modbus RTU
Termination Style
Screw
Mounting Style
140 x 420 mm Wall Mount
Case Material
PC - UL 94 V0
Weight
3.6kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron Electronics GBMA-4-DA6-ANAY, 140x420mm Digital Ammeter, Panel Mount, 4-20mA Input, 100-240VAC/VDC supply, 4-20mA Transmission Output, with IR Remote Control, RS485 Modbus RTU
Adjustable Zero and Span Setting
Adjustable Display Scaling
Remote Control Included
RS485 Modbus RTU
Wall Mount
LED Tile Display
Large 4 Digit 100mm (40 Inch) LED Display
250mS Response Time
PC 94 UL V0
100mm Depth
CE Approved
Specification
Fastron Electronics Part Number
GBMA-4-DA6-ANAY
Conditioner Output
4-20mA
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Comms
RS485 Modbus RTU
Termination Style
Screw
Mounting Style
140 x 420 mm Wall Mount
Case Material
PC - UL 94 V0
Weight
3.6kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Crouzet 84873024, 3 Phase Voltage Monitoring Relay With 17.5mm SPDT Contacts, 3 x 208 - 480 V AC MWA, Sequence, Failure, Imbalance (asymmetry), Under/Over
MWA relays control, on 3-phase networks :
Overvoltage between phases,
Undervoltage between phases
Asymmetry (Imbalance)
Sequence Detection
Controls its own supply voltage
True RMS measurement
LED status indication
3-phase voltage controllers which monitor :
Undervoltage, adjustable from -20 to -2 % of Un
Overvoltage, adjustable from 2 to 20 % of Un
Asymmetry, adjustable from 5 to 15% of Selected Un
Presence of the neutral (H3USN only) Measurements are taken between Phases for the H3US
M3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Set the selector switch to the 3-phase network voltage Un.
The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation.
Specification
Crouzet Part Number
84873224 (3 Phase Voltage Monitoring Relay With SPDT Contacts)
Function
Undervoltage/Overvoltage between phases
Nominal Voltage
3 x 208 → 3 x 480 V ∿
Digital Outputs
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Timing Range
0.3 → 30s (0, +10%)
Delay on Pickup
500ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Fixed Hysteresis
2% of Un
Maximum Measurement Cycle Time
150ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement 3 x 208 → 3 x 480 V ∿
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Application Notes
Legend
1
Overvoltage
2
Hysteresis
3
Undervoltage
4
Phases L1, L2, L3
5
Relay R1
6
Relay R2
7
Overvoltage threshold delay
8
Undervoltage threshold delay
The relay monitors its own supply voltage. It controls :
Undervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V ∿ range due to the minimum voltage 194 V ∿)
Overvoltage, adjustable from + 2 to +20 % (+2 to +10 % over the 3 x 480 V ∿ range due to the maximum voltage 528 V ∿). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. The relay monitors its own supply voltage. It controls :
Presence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %. Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output/one overvoltage output) opens at the end of the time delay set by the user. If neutral is lost, both relays open instantaneously and the corresponding LED is extinguished, without waiting for the end of the time delay. The two relay LEDs are extinguished.
Fastron Electronics SCT-F16-25, 25/0.333V Measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-25
Technology
Split Core AC Current Transformer
Ratio
25/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
25Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes