Vishay VSKL91/16, Dual Thyristor Module, Common Cathode 91 Amp, 1600V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKL91/16
Vrrm
1600V
Diode Configuration
Dual Thyristor Module, Common cathode
IF(av) @ 85 Deg C
95 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2.0 kA
VF(to)
1.1V
Tj(max)
125°C
rF
2.38mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See TT92N16K or TT104N14K for Infineon Pressure Contact Alternative, or for IXYS solder bonded Alternative MCC95-16
Crydom 84140900, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84140900
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Gigavac GX16FEB, Contactor SPST-NO, 600+ AMP, 12-800VDC, 48VDC Coil, 8 Pin Deutsch Conector, SPST-NO Auxiliary Contact, IP67, IP69K
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GX16FEB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
48VDC
Load Current
600+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
8 Pin Deutsch Conector
Aux Contact Terminals
8 Pin Deutsch Conector
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
900g
Factory Pack Qty
1
Datasheet
Product Datasheet
C100N+100R-Lugged, RC Snubber Network 275VAC, Class X2, 100uF 100 Ohm Lugged for SSR or SCR Terminal Mounting
These snubber neworks are suitable for transient supression in small contactors, bridge rectifers, or solid state relays switching AC or DC Loads. Easily connected or lugged to solid stage relay or power module terminals. See EMC filters, and Metal Oxide Varistors sections for additional supression components.
As and added bonus, these Snubber Networks Improve the Power Factor of switched loads.
Datasheet
Product Datasheet
Crydom HDC100D160, 3.5-32VDC Input, 7-100V, 160Amp DC Output Solid State Relay
Features
Ratings from 100A to 160 Amp @ 7-150VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HDC100D160
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
160 Amp DC
Surge Capability (10ms)
470 Amp DC
Special Feature
High Current Stud Terminals
Mounting Style
Panel Mount
Load Voltage Range
7 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
345g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DC60SA3, Solid State Relay, DC 90-280VAC/DC control, 3A, 60VDC Load
Features
Ratings from 3A to 40 Amp @ 3-60VDC
Transistor output
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DC60SA3
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
90-280VAC/DC
Load Current
3 Amp DC
Surge Capability (10ms)
6 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
3 - 60VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See D1D40K with raised terminals (Gen 3) for alternative or DC60S7, D1D20, D1D40, D1D80 for higher current alternatives
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Gigavac P105CDA, MiniTactor Contactor SPST-NO, 50 AMP, 1200VDC, 24VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Features
Perfect for Photovoltaic/Battery Systems
Hermetically Sealed (Patented) rated to 175 Deg C
High Efficiency Dual DC Coils - 12,24,48VDC options
Ideal for battery powered systems or where low power is needed
Built in Coils suppression for all DC Coils
Small and lightweight
Flexible package for installation
Chassi level power terminals
Specification
Gigavac Part Number
P105CDA
Main Contact Type
SPST-NO
Auxiliary Contact Type
N/A
Coil Voltage
24VDC
Load Current
50 Amp
Mechanical Life @ 0 Amp
100,000 Operations
Dielectric at Sea Level
4.3kV rms
Control Input Terminals
M3 Screw
Special Feature
N/A
Mounting Style
Panel Mount (M4)
Load Voltage Range
1200VDC
Standards
UL508, NEC 690.11 and 690.12 DC
Termination Style
M4 Screw
Unit Weight
135g
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter 4781.0100, IEC Appliance Plug C15/F, Rewirable, Black, for 3 x 1.5m sqr/14AWG Maximum wire size, 10mm Type
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet C15/F Plug acc to IEC 60320-1
Screw On Mounting
120 °C Operating Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
4781.0100
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 120°C
Mounting
Wire Screw Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
C15 Female to Screw Terminal
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
Rishabh CT 300/5 Class 0.5 15VA 86/40 (45), Current Transformer 300/5Amp CT 15VA, Class 0.5 HIGH BURDEN
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 300/5 Class 0.5 15VA 86/40 (45)
Technology
AC Current Transformer
Ratio
300/5
Aperture Size
36mm or 11x41mm Busbar
VA Rating
15VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Moun
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics SCT-F16-100-1A, 1 Amp Output, 100Amp measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-100-1A
Technology
Split Core AC Current Transformer
Ratio
100/1A
Aperture Size
ø 15 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide