Fastron FPC1-63-04C-230VAC, 4 Pole 4 x SPST NC, Modular Contactor 440VAC 63 Amp 50/60Hz, 230VAC Coil Voltage, Hum Free
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
FPC1-63-04C-230VAC/DC
Switching Type
4 x SPST NC
Approvals
CE
Coil Voltage
230VAC/DC, 50/60Hz
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC, 50/60Hz
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Auxiliary Contacts Selection Guide
LEM AI-PMUL Universal Integrator for Rogowski Coils, Multi Range Input (100 to 5000 Amp) and Output (0.333V,0.225), and True RMS outputs (4-20mA,0-20mA,0-5V,0-10V), Adjustable Sensitivity(22.5,70,80,85,100,120mV/kA), Din Rail Mount
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both True RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. optional
Input signal
Accuracy Class 0.5 (IEC 61869-2) [1].
Linearity error ? 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature ?25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 0.5 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross power plugin connector: side contacts to stack up to 3 Integrator modules and use only one power supply.
24VDC Power Supply Meanwell HDR-15-24
Specification
LEM Part Number
AI-PMUL
Function
Integrator and True RMS Conditioner for Rogowski Coils
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
0.5% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm
Mounting
Din Rail Mount
Integrator to Meter cable
User Supplied Shielded cable 6mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
Product Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
VFD45AMS43ANSAA, 3 Phase, Variable Frequency Drive, 22kW, 34.3 Amp (Normal Duty)/37.3 Amp (Heavy Duty), 460VAC L-L, 300x175x192mm
Features
3 Phase VFD/VSD
4-20mA, 0-5V, 0-10V Proportional Input Control
7 x Digital Input
2 x STO Inputs
Fully enclosed IP20 (Optional IP40)
Small frame Size
Applications
Fan Motor Control
Production Lines
Transportation
Controlled Power Applications
Suitable for extreme environments such as mining
Specification
Delta Part Number
VFD38AMS43ANSAA
Rated Operation Temperature
50°C (With Derating)
Configuration
3 Phase AC Drive
Control Voltage
4-20mA, 0-20mA, 0-10V
Digital Inputs
7 x Mix / 2 x STO
Load Current
24.4 Amp(Normal Duty) / 27.4 Amp(Heavy Duty) Per Phase
Control Range
0.1-599 Hz
Dimensions
250x130x185mm
Mounting Style
Panel Mount
Supply Voltage Range
323-528VAC
Soft Start
0-6000s
Termination Style
Screw
Unit Weight
6.5kg
Factory Pack Qty
1
Datasheet
MS300 Brochure
User Manual
Trent FYRP240I80P, Phase Angle Controller, 4-20mA Control, 110-240VAC 80Amp Load, SCR Output
Features
470kOhm - 1 MOhm POT Phase Control Input
Ratings from 40A to 80 Amp @ 110-480 VAC
SCR output for heavy industrial loads
Instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
TRENT Part Number
FYRP240I80P
Switching Type
Phase Angle (Random Crossing)
ROHS/CE
Compliant
Control Input
4-20mA
Load Current
80 Amp (rms)
Surge Capability
900 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
110-280VAC
Max Non Repetitive Peak Voltage
850 Vp
Termination Style
Screw
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
Equivalent
Relequick RS1API420MA280080R
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
RODNV624010, Steel Teclom Enclosure IP55, AIR COOLED 578M3/h, RAL 7035 Gray, 2.0mm Galvanised Steel, Thermostat and Fan Pre-installed
Features
Thermostat Controlled Dual Fans for 578m3/h maximum flow rate
Lockable Door via Key
Stack multiple modules for larger Power Factor Correction Requirements
Optional HMI IP55 Door with Window RODNV624010
Specification
Fastron Part Number
RODNV624010
Function
Steel Water Proof Enclosure AIR COOLED
Configuration
Enclosure with Hinged Door, Key Lock and Fan and Thermostat
Air Flow Rate
578m3/h
Termination Style
Screw
Dimensions
L:950 x W:950 x H:1200mm
Weight
70kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
2.0mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP55
Operating Temperature
-20...55 °C
Datasheet
Datasheet
FBS LCD 24/4M, 24VDC Surge Protection Device for IT Systems, LPZ 0A-2 of higher, 10kA
Specifications
Telebahn part number
FBS LCD 24/4M
Nominal Voltage
24VDC
No of Poles
4
Category IEC / EN / VDE
Type 2
Location of use
Communication/Signal Lines
Protection modes
L1+/L1-, L2+/L2- , for
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
N/A
Surge discharge rating
Per pole 10kA (8/20uS)10KA) Max, 20kA (8/20uS)2.5KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
120g
Standards
IEC 61643-21; EN 61643.21; GB 18802.21
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Fastron FEFN101-36-M, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 36 Amp, FMAD NEO, 520VAC, Very High Attenuation
Features
Line filter suitable for 3 Phase + N systems
Wide Temperature Range
Characteristics
Designed for demanding applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Suitable for use in equipment according to UL 1238, CSA22.2N).8, IEC/EN 60939
Line filter suitable for low current Inverter such as PV or battery storage systems
Specification
Schurter Part Number
FEFN101-36-T
Rated Voltage
520V 3 Phase
Rated Current
36Amp @ 40 Deg C
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.5mA
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
1.3kg
Factory Pack Qty
4
Protection Class
Suitable for equipment according to IEC/UL 60950
Isolation
1.3 - 2.75kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Gigavac GXL14C1AB, Latching Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K, High Side Drive Version
Features
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GXL14C1AB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC (Low Side Drive, refer datasheet)
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C, High Side Drive Version
Mounting Style
Panel Mount (M5)
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
RODNV624011, Steel Teclom Enclosure with HMI Windowed Door IP55, AIR COOLED 578M3/h, RAL 7035 Gray, 2.0mm Galvanised Steel, Thermostat and Fan Pre-installed
Features
Thermostat Controlled Dual Fans for 578m3/h maximum flow rate
Lockable Door via Key
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
RODNV624010
Function
Steel Water Proof Enclosure
Configuration
Enclsure with Hinged Door, Key Lock and Fan and Thermostat
Air Flow Rate
578m3/h
Termination Style
Screw
Dimensions
D:430 x W:680 x H:1200mm
Weight
70kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
2.0mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP55
Operating Temperature
-20...55 °C
Datasheet
Datasheet
Fastron FTH12053ZA4, Solid State Relay, 3 Phase 90-280VAC Control, 120A, 70-530VAC Load 3 Phase Solid State Relays, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
FTH12053ZA4
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
120 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator & IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
FAST ONE SLIM AHF-44A-400-4W, Active Harmonic Filter & Static Var Generator, 30Kvar/44 Amp, 3 Phase 4 Wire, 380VAC +/-20%, RACK MOUNT ONLY, NOTE for AHF function the module is limited to 30 Amp
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. and for the filtering or control of Harmonic Distortion
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Overtemperature Alarm
Optional RS485 Comms
3 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installtions
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Specification
Fastron Part Number
FAST ONE SLIM AHF-44A-400-4W
Function
Reactive Power Correction & Rack Mounted Active Harmonic Filter
Rating
44 Amp @ 50 Deg C /30Kvar (note for AHF function, Current should be limited to 30 Amp
Nominal Voltage (Un)
380VAC Line to Line 50Hz +/-20%
Switch Delay Time
Instant Correction/Inverter Based
Desired Harmonic
0.99 IND - 0.99 CAP
LCD Display Accuracy
IGBT Temp, Grid Current Grid THDi, Grid PF, Grid Imbalance
Current imbalance
< 5%
Comms
RS485 (Optional)
Mounting Style
, RACK MOUNT ONLY
Termination Style
Screw
Dimensions
D:400x88.2x448.5
Weight
17kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
User Manual
Datasheet
Advanced Energy Thyro-A-1A-500-30-H-RLP3, Thyro-A-1A-Series Single Phase SCR Controller 30Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Features
Optional Profinet,Profibus,Ethernet,Modbus Comms
500VAC +10/-57% Voltage, Current or Power Control
Built in Fuse
Smallest footprint on the market
Single Phase Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
Quick TAKT Mode (QTM), VT Mode (on request)
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
Potentiometer Adjustment
USB Configuration/Bias Setting
Synchronisation Function (dASM Module Recommended)
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
AC Soft Starter (Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro-A-1A-500-30-H-RLP3
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
500VAC +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 30kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
Thyro A Series Quick Installation Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide