Iskra ISPRO-K BSR 75/440 (3+0), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount
Specifications
Iskra Doo part number
ISPRO-K BSR 75/440 (3+0)
Nominal Voltage
440VAC
No of Poles
3
Category IEC / EN / VDE
Class I,II / Type 1,2 / B,C
Location of use
Main Distribution Boards
Protection modes
L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Protective element
MOV + GDT
Surge discharge rating
Imax up to 75 kA, or 25kA per pole
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
Fastron Electronics SCT-F16-150, 0.333V Output, 150Amp measurement Split Core Current Transformer, 16mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-150
Technology
Split Core AC Current Transformer
Ratio
150/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
150Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Rishabh CT 400/5 Class 0.5 5VA 50/30 (30), Current Transformer 400/5Amp CT 5VA, Class 0.5 Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 400/5 Class 0.5 5VA 50/30 (30)
Technology
AC Current Transformer
Ratio
400/5
Aperture Size
28mm or 10x30mm Busbar
VA Rating
5VA
Accuracy Class
Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
400Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron FCR-400-60R, Three Phase Proportional Phase Control Module, 4-20mA,0-10V,500K POT Input, 400VAC, 60 Amp Per Phase, Also referred to as 3 Phase Voltage Regulator
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FCR-400-60R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
60 Amp (rms) @ 40 Deg C
Surge Capability
597Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FCR-400-60R
RTR Energia EA0525250500000 Power Factor Correction Capacitor, Single Phase, Dry Type 2.5 KVAR, 28.87uF, 525V, 50HZ, 60 x 150mm
Characteristics and utility
2.5 kVar @ 525V @ 50 Hz, 28.87uF.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525250500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
2.5 Kvar
Capacitance
28.87uF
Tolerance On Capacitance
-5% + 10%
Current (In)
4.76 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
RTR Energia EA0525167500000 Power Factor Correction Capacitor, Single Phase, Dry Type 1.67 KVAR, 19.29uF, 525V, 50HZ, 60 x 150mm
Characteristics and utility
1.67 kVar @ 525V @ 50 Hz , 19.29uF10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525167500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
1.67 Kvar
Capacitance
19.29uF
Tolerance On Capacitance
-5% + 10%
Current (In)
3.18 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
RTR Energia EA5252000500000 Power Factor Correction Capacitor, Single Phase, Dry Type 20 KVAR, 525V, 230.97uF, 50HZ, 120 x 225mm
Characteristics and utility
20 kVar @ 525V @ 50 Hz, 230.97uF
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA5252000500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
120 x 225mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
20 Kvar
Capacitance
230.97uF
Tolerance On Capacitance
-5% + 10%
Current (In)
38 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.2kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
RTR Energia EA0525660500000 Power Factor Correction Capacitor, Single Phase, Dry Type 6.60 KVAR, 525V, 50HZ, 60 x 200mm
Characteristics and utility
6.6 kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525660500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 200mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
6.6 Kvar
Capacitance
231uF
Tolerance On Capacitance
-5% + 10%
Rating
38 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Fastron Electronics SCT-F16-75, 75/0.333V Measurement Split Core Current Transformer
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F16-75
Technology
Split Core AC Current Transformer
Ratio
75/0.333V
Aperture Size
ø 15 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
75Amp x 1.2
Termination Style
0.5M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes