Search results for "digital-mustimeter"
-
DTS 1 UNI V2, Dual Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 1 x 16 Amp SPST CO Relay
Free Aus Post Shipping for $300 SpendIskra Two Pole DTS 1 UNI V2, Dual Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 1 x 16 Amp SPST CO Relay DTS 2 UNI V2 24-240 V AC/DC - 2 Relay 16A : Multi-range (1 Min - Yearly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 1 UNI V2 Function Daily, Monthly, Yearly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 1 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet User Manual  Â
-
VA702, Portable Volt/mA/ThermoCouple Calibrator For Input/Output Voltage, with USB and Free software, Optional External AC Adaptor, WITH 10 Group Recall/Store Function
Free Aus Post Shipping for $300 SpendVA Instruments VA702, Portable Volt/mA/ThermoCouple Calibrator For Input/Output Voltage, with USB and Free software, Optional External AC Adaptor, WITH 10 Group Recall/Store Function  For Testing of: Volt and mA Calibrator For; Type K, J, E, T, N, S, R, B Thermocouples (see table) Input/Output Voltage Range -10mV to 100mV Voltage Resolution 0.01mV Voltage Accuracy +/-(0.025%+2) Input/Output Current Range 6 x AAA Batteries 205 x 97 x 45mm with USB and Free software Optional External AC Adaptor WITH 10 Groups Store and Recall Feature Specification Datasheet Datasheet Â
-
DE72/600/5A, Moving Iron Ammeter, 600/5A, 72 × 72mm, Class 1.5
Free Aus Post Shipping for $300 SpendRishabh DE72/600/1A Moving Coil Ammeter Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DE72/600/5A Nominal Measurement Range 0 - 600 Amp AC Maximum Measurement Range 600 Amp Over Range Isn x 2 (10 Amp) Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
-
VA6520, Infra Red Thermometer /Probe Range -50 ~ 20 Deg C / -20 Deg C (-58 Deg F to ~932 Deg F). TAMB Measurement 0~50 Deg C. Resolution 0.1 Deg C D:S Ratio 8:1. Up to 1.5m Distance. OL or -OL Overrange. Fixed Emissivity 0.95
Free Aus Post Shipping for $300 SpendVA6520, Infra Red Thermometer /Probe Range -50 ~ 20 Deg CÂ / -20 Deg C (-58 Deg F to ~932 Deg F). TAMB Measurement 0~50 Deg C. Resolution 0.1 Deg C D:S Ratio 8:1. Up to 1.5m Distance. OL or -OL Overrange. Fixed Emissivity 0.95 Features Portable /Battery Powered 3 x AAA Range -50 ~ 20 Deg C +/-5 Deg C / -20 Deg C ~5 Reading Deg C 1.5% + 2 Deg C (-58 Deg F to ~932 Deg F) TAMB Measurement 0~50 Deg C Resolution 0.1 Deg C D:S Ratio 8:1 Up to 1.5m Distance OL or -OL Overrange Fixed Emissivity 0.95 1 second Response Time 8-14um Spectral Response 1mW laser Single Laser Measurement Datasheet Datasheet
-
MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms
Free Aus Post Shipping for $300 SpendIskra Doo MC774 S HEWNNN, Power Quality Analyser Class A, 32uS sampling, 16-400Hz, 140 Parameter Measurement, Time Sychronisation support, 80-276VAC or 70-300VDC Power Supply, Three Independent Comm Ports, GPS, IRIG-B, and NTP Time, Up to 20 Input and Outputs, Ethernet and USB Comms, 1 x Status and 1 x Relay Output Class A Instrument Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 1000rms V L-N 50/60Hz Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication The POwer Quality Analyser is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, energy, energy price by tariffs, etc.). Accuracy class 0.5 or 0.2 (on demand) Measurement of 40 minimal and maximal values in different time periods Optional 32 adjustable alarms Optional wide frequency range from 16 Hz to 400 Hz Optional RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication Optional MODBUS and DNP3 communication protocol MMC memory card for setting and upgrading the meter Up to 20 inputs or outputs (analogue outputs, pulse outputs, alarm outputs, tariff inputs) 1 Status and 1 Relay Output Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 750 V Adjustable tariff clock, display of electric energy consumption in optional currency Multilingual support User-friendly PC MiQen software 128 samples in one period Measurement of THD on Current or Voltage from 0 to 400% Measure to the 65th Harmonic Specification Iskra Doo Part Number MC774 S HEWNNNT Functions Power Quality Analyser, Energy Meter, Power Transducer, Network Recorder/Analyser Supply Voltage 240VAC < 5VA Nominal Measurement Range 750Vrms L-N, 5 Amp 50/60Hz Maximum Measurement Range 1000Vrms L-N, 12.5 Amp 50/60Hz Alarm N/A (Optional 4 Relays, 32 Alarms, 4 Groups) Analogue Output N/A (Optional 4 x 20mA) Digital Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Pulse Output N/A (Optional) Pulse Input N/A (Optional) Bistable Switch/Latching Relay Alarm N/A (Optional) Status (Watchdog) Output N/A (Optional) Tariff Input N/A (Optional 4 x 230VAC/DC,75..130VAC/DC..5..48VAC/DC) Accuracy Class 0.5 (I,U,F,PF,θ,THD) (Class 0.2 Optional) Class 1(Active), Class 2 (Reactive) Battery Backup Supercap Real Time Clock 1min/month (30ppm) Internal Memory 8MB MMC up to 1GB Isolation 3.7kV Ethernet Yes (RJ45 10/100Mbit/s) USB Yes (2400-115200 b/s) RS232/RS485 Optional Weight 600g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet User Manual
-
DT9-216/D12001, Dual Digital Time Switch with 2 independant Daily Weekly, Monthly, Yearly, Astro, Random program, Universal 12VDC Power Supply/Control, 2 x 16 Amp SPST CO Relay
DT9-216/D12001, Dual Digital Time Switch with 2 independant Daily Weekly, Monthly, Yearly, Astro, Random program, Universal 12VDC Power Supply/Control, 2 x 16 Amp SPST CO Relay DT9-216/AD240001 UNI 12VDC - 2 Relay 16A : Dual Timer Multi-range (1 min - yearly) Astro Timer Function Random Timer Function Multi-voltage 24 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Assudum Part Number DT9-216/AD240001 Function Daily, Monthly, Yearly, Astronomical, Random Time Switch Nominal Voltage 24VDC Digital Output 2 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months, Years, Astronomical, Sunset, Random Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet Product Datasheet Â
$79.00
$93.22 inclGST -
ITZ 16000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 16000 Amp peak, 2000mA Output, 150.3mm Aperture, 100-240VAC Supply
Heavy item - No Free ShippingITZ 16000-S FLEX ULTRASTAB High Precision Hall Effect Current Sensor, 16000 Amp peak, 2000mA Output, 150.3mm Aperture, 100-240VAC Supply Datasheet Product Datasheet
-
DK 100 C5, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 C5, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-5V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-5V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C5 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-5V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DTS 3 UNI, Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 16 Amp SPST CO Relay
Free Aus Post Shipping for $300 SpendIskra Single Pole Time Switch with SP-NO/NC Contacts DTS 3 UNI 24-240 V AC/DC - 1 Relay 16A : Multi-range (1 Min - Yearly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 3 UNI Function Yearly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 1 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet Product Datasheet Catalogue  Â
-
TSD 2 230VAC, Twilight Switch with Digital Time Clock, 230VAC +/-10% Power Supply, 8 Amp SPDT CO Relay
Free Aus Post Shipping for $300 SpendIskra Doo TSD 2 230VAC, Twilight Switch with Digital Time Clock, 230VAC +/-10% Power Supply, 8 Amp SPDT CO Relay TSD 2 Series serves to monitor Light levels (10 - 50,000 lx) based on ditigal time clock settings, and provides Relay alarm output with digital adjustable timing function. Features : Timer overide feature for times when light is not reqtuired in the dark Random Switching to Simulate Presence in House Used to control lights on the basis of ambient light intensity External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package) Time Switch Control Red LED output indication 2-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device Control input for additional control, e.g. time switch, preswitch etc. Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination Supply voltage AC 230 V or AC/DC 12 - 240 V Output contact: 1x changeover/ S Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Iskra Doo Part Number TSD 2 230VAC Voltage Range AC 230 VAC Operating Range -15 %; +10 % Light intensity sensing range 10 - 50,000lx Time Adjustment Digital Menu Setting Accuracy +/-1s per day at 23°C Burden max. 12 VA Repeatability 1 % Temperature Drift 0.1%/°C Output SPDT Relay 8 Amp Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 8 A / AC1 Breaking capacity 4000 VA / AC1, 384 W / DC Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 109 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet
-
MT406-54, AC Voltage Transducer, Class 0.5, 110VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span
Free Aus Post Shipping for $300 SpendIskra Doo MT406-54 Series Single Phase AC Voltage Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-20mA analogue Output Average RMS values of voltage Features : Measurement of up to 132VAC Self Powered Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT406-54 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 0-110VAC Maximum Measurement Range 0-132VAC Output 0-20mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20  Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C  Datasheet Product Datasheet Â
-
DTS 2 UNI V1, Dual Digital Time Switch with Daily Weekly and Monthly Program, Universal 12-240VAC/DC Power Supply/Control, 2 x 16 Amp SPST CO Relays
Free Aus Post Shipping for $300 SpendIskra Single Pole DTS 2 UNI V1, Dual Digital Time Switch with Daily Weekly and Monthly Program, Universal 12-240VAC/DC Power Supply/Control, 2 x 16 Amp SPST CO Relays DTS 2 UNI V1 24-240 V AC/DC - 2 Relay 16A : Multi-range (1 Min - Monthly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 2 UNI V1 Function Dual Weekly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 2 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet Product Datasheet Catalogue  Â