Search results for "digital-mustimeter"
-
Rish Delta Energy-EA-Z-R, Panel Mount kWh Meter, 480VAC 3 Phase Class 1, 5A/1A seletcable CT secondary, 40-300VAC/DC Supply, RS485 Modbus RTU
Free Aus Post Shipping for $300 Spend96x96mm Panel Mount kWh Meter, 500V, 5A/1A seletcable CT secondary, 40-300VAC/DC Supply, RS485 Modbus RTU Optional Pulse Output Nominal current up to 1.2A/6 A (For 1/5A CT Input) and nominal voltage up to 290V L-N, 500V L-L Three Line Display RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS communication protocol 240V AC power supply Specification Northern Design Part Number Rish Delta Energy-EA-Z-R Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms Modbus RTU Over TCP/IP 2400-19200 b/s Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Lead time 3-4 weeks if not in stock
-
DE72/500/5A, Moving Iron Ammeter, 500/5A, 72 × 72mm, Class 1.5
Free Aus Post Shipping for $300 SpendRishabh DE72/500/1A Moving Coil Ammeter Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DE72/500/5A Nominal Measurement Range 0 - 500 Amp AC Maximum Measurement Range 500 Amp Over Range Isn x 2 (10 Amp) Operating Temperature 0 - 50°C Frequency 15...500Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
-
DS96/200A/60mV, Moving Coil Ammeter 200Amp DC for 200A/60mV Shunt Connect
Free Aus Post Shipping for $300 SpendRishabh DS96/200A/60mV, Moving Coil Ammeter 200Amp DC for 200A/60mV Shunt Connect Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DS96/200A/60mV Nominal Measurement Range 0 - 200 Amp AC Shunt Input 0-60mV Unipolar Maximum Measurement Range 200 Amp Over Range Ipn x 2 Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
-
DVL 1500/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts
Free Aus Post Shipping for $300 SpendLEM DVL 1500/SP7 Digital Voltage Transducer, Vpn = 1500V, 10V output, +/-15...24VDC powered, 8.5kV Isolation, Output Connections M5 Inserts Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Output Connections M5 Inserts Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 1500/SP7 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 1500V Measurement Range +/- 2250V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style Output Connections M5 Inserts Unit Weight 270g Factory Pack Quantity 4  Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Â
-
Rish Delta Energy-EA-Z-Z, Panel Mount kWh Meter, 480VAC 3 Phase Class 1, 5A/1A seletcable CT secondary, 40-300VAC/DC Supply
Free Aus Post Shipping for $300 Spend96x6mm Panel Mount kWh Meter, 500V, 5A/1A seletcable CT secondary, 40-300VAC/DC Supply Optional Pulse Output Nominal current up to 1.2A/6 A (For 1/5A CT Input) and nominal voltage up to 290V L-N, 500V L-L Three Line Display RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Optional THD up to 15th Harmonic The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 1 Simple Menu Optional RS 232/RS 485 communication up to 19,200 bit/s or Ethernet communication MODBUS communication protocol 240V AC power supply Specification Northern Design Part Number Rish Delta Energy-EA-Z-Z Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 415V L-L 240V L-N, 5 Amp Maximum Measurement Range 415V L-L 280V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 1 (kW,kWh) Class 1(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms Optional RS485 Modbus RTU Weight 350g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Lead time 3-4 weeks if not in stock
-
E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Secure E500R-51D2, Panel Mount Network Recorder & 1000A/140mm Rogowski Coils, with Harmonics (15th), Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Logging Memory, TFT Touch Screen Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N Dual Loggers, configurable for Instant or accumulated energy RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval RS 485 communication up to 38400 bit/s as standard Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Optional Modules for Analogue outputs and Relay Alarms  The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.  Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th Accuracy class 0.5S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s MODBUS communication protocol Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850 Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs Universal or AC/DC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software Specification Secure Part Number E500R-51D2 Functions Power Quality Meter, Energy Meter Rogowski Coil Rating/Size 1000A/140mm Supply Voltage Universal 35..300V DC, 85..300VAC Nominal Measurement Range 240V L-N, 100mV/kA @ 50 Hz, 415V L-L Maximum Measurement Range 300V L-N, 100mV/kA @ 50 Hz, 500V L-L Alarm Optional Module 2 Relay/Pulse Outputs Tariff/Digital Inputs TOU Tarriff Clock Accuracy Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Analogue Output Optional Module 2 x Programmable Analogue Outputs Internal Memory 2 x 8MB Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS232/RS485 N/A Optional CT Termination Ring Terminals Weight 600g Certification CE, CSA, ROHS Warranty 10 Years from dispatch from Secure Warehouse Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997  Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C  Datasheet Product Datasheet Cross Reference  The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team Elite 500_400_300_100 series competition replacement for Schneider Siemens Accuenergy (RS485 +DNP3 default) Socomec Selec PM 5000 series PAC 2000 series ACCUVIM-CL + DNP3.0 DIRIS A-20 Selec MFM376 PM 5100 PAC 3200 ACCUVIM-CL + DNP3.0 DIRIS A-20 MFM384, CL-1, RS485 PM 5300  ACCUVIM-IIR DIRIS A-20 MFM383A PM 5500 PAC 4200 ACCUVIM-IIR(+ BACnet) DIRIS A-20 MFM384. RS485 PM 6463 Siemens 7KMPAC4200 ACCUVIM-IIR (+ Profibus) DIRIS A-30/ DIRIS - A60 (PQ Feature) MFM384-C-CE-CL05, RS485 PM 5650  ACCUVIM-IIR (+ IEC 61850) DIRIS A-30 + Profibus MFM384-C-CE-CL05, RS485 PM 5760  ACCUVIM-EL DIRIS A-30 +Ethernet MFM384-C-CE-CL05, RS485 PM5330  ACCUVIM-EL (+ BACnet) DIRIS A-30/ DIRIS A-60  PM 5560  ACCUVIM-EL (+ Profibus) DIRIS A-30/ DIRIS A-60  DM6200H  ACCUVIM-EL (+ IEC 61850)   PM2220  ACCUVIM-II R +Ethernet   PM2230 / DM2120 (LED)     PM 5350    Â
$1,437.00
$1,695.66 inclGST -
Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84
Heavy Item - No Free ShippingSecure Sprint 350 3P4W 100 Amp RS232, Three Phase Revenue Grade Meter for Small Commercial Applications, 100 Amp Direct Connect, RS232 Comms, NMI NMI 14/2/84 Three Phase Revenue Grade Meter for small commercial applications Usage The meter is intended for measuring, monitoring three-phase electrical power network in residental, or small commercial applications for billing purposes. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Specification Secure Part Number Sprint 350 3P4W 100 Amp Functions Commercial Billing Meter with LCD Display Nominal Measurement/Supply Range 3 x 100/240/400VAC, 10/100 Amp 50Hz Maximum Measurement Range 460VAC, 10/100 Amp 50Hz 4 Quadrant Measurement Import/Export Tariff Input N/A Accuracy Class 1 Comms RS232 (Optional 4G available) Weight 2000g Certification CIEC/AS 62052-11, IEC/AS 62053-21, NMI M6-1 Factory Pack Qty 1 Safety IP53 Enclosure Material Engineering Plastic Optional RTC,Load Profile, RS485 Interface, Outputs Operating Temperature -40 →+80 °C Datasheet Datasheet IGC meters MT860 MT830/831 ICG Meter Shortform
-
88981123 em4 Alert 3G, 16 digital inputs (including 4 High Speed, 8 analog 0-10 V / potentiometers and 4 analog 0-10 V / 4-20 mA), 10 digital outputs (including 2 solid states 0.5 A PWM, 2 relays 6 A and 6 relays 8 A)
Free Aus Post Shipping for $300 SpendCrouzet 88981123 em4 Alert 3G Programmable Logic Controllers 3G Comms built in Up to 104 I/Os - 16 DI (4 HighSpeed / 8 AI) 10 x DO (2 x Solid State 0.5Amp PWM, 2 Relays 6 Amp, and 6 Relays 8 Amp) Wireless Programming & Control with native 3G and Crouzet Virtual Display Modbus RTU Network (Slave) Local datalog management Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications HMI Screens Available Specification Crouzet Part Number 88981123 (em4 Alert 3G) Analogue Inputs 12 x 0 - 10VDC, (4 High Speed) Digital Inputs 24VDC @ 2.1mA (8 Standard and 4 High Speed) Digital Outputs Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp) PWM SSR Output 2 Expandable Yes Comms 3G. (RS485, Bluetooth,Ethernet,Standard) and Wifi versions available LCD Display Yes Mounting Style DIN Rail Mount (124.6mm) Supply Voltage Range 24VAC (21.6 - 28.8VAC) Termination Style Screw Weight 350g Environmental Reach, RoHS, Halogen free 1272/2008/CE Certification CE, cULus Listed Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet Product Datasheet Software Crouzet Touch Soft V6.00.02.173 Software M3-soft-AC9-V3.1.2.0_ML Remote Control Software CVD_PC_V2_3_01_02 Crouzet Soft EVO EM4 1.12.01.14 Â
-
DS72/150A/60mV, Moving Coil Ammeter 150Amp for 150A/60mVDC Shunt Connect
Rishabh DS72/250A/60mV, Moving Coil Ammeter 250Amp for 250A/60mVDC Shunt Connect Moving Coil Ammeter Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72x72mm Panel Space 65mm Depth Specification Rishabh Part Number DS72/150A/60mV Nominal Measurement Range 0 - 150 Amp DC Shunt Input 0-60mV Unipolar Maximum Measurement Range 150 AmpDC Over Range Ipn x 2 Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals with back cover Termination Style Screw Mounting Style 96 x 96mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1  Datasheet Product Datasheet
$69.50
$82.01 inclGST -
DE72/200/5A, Moving Iron Ammeter, 200/5A, 72 × 72mm, Class 1.5
Free Aus Post Shipping for $300 SpendRishabh DE72/200/1A Moving Coil Ammeter Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 72 x 72mm Panel Space 65mm Depth Specification Rishabh Part Number DE72/200/5A Nominal Measurement Range 0 - 200 Amp AC Maximum Measurement Range 200 Amp Over Range Isn x 2 (10 Amp) Operating Temperature 0 - 50°C Frequency 15...200Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 72 x 72mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet
-
DTS 1 UNI V2, Dual Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 1 x 16 Amp SPST CO Relay
Free Aus Post Shipping for $300 SpendIskra Two Pole DTS 1 UNI V2, Dual Digital Time Switch with Daily Weekly, Monthly, and Yearly program, Universal 12-240VAC/DC Power Supply/Control, 1 x 16 Amp SPST CO Relay DTS 2 UNI V2 24-240 V AC/DC - 2 Relay 16A : Multi-range (1 Min - Yearly) Multi-voltage 12 →240 V AC/DC LED status indicator Possibility of external load connection in parallel to the control input Specification Iskra Part Number DTS 1 UNI V2 Function Daily, Monthly, Yearly Time Switch Nominal Voltage 24 → 240 V AC/DC Digital Output 1 x C/O (SPST) (Changeover -Single Pole), 250VAC/DC @ 16 Amp Min Breaking Current 10mA/12VDC Timing Ranges Minutes, Hours, Days, Weeks, Months Minimum Pulse Duration 30ms/100ms with load Repeatability 0.5% Reset Time 120ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 80g Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22  Datasheet User Manual  Â
-
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range
BA1-ND21-2, Indicator, 48x24mm, 5VDC, 4-20mA Input, 0-100.0 Display Range 3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) UL/CE Approved Each unit needs just 40 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number BA1-ND21-2 Control Output 1 (Heat) N/A Control Output 2 (Cool) N/A Input 4-20mA (0-100.0) Alarm N/A Option 1 N/A Mounting Style 48 x 24mm Panel Mount Supply Voltage 5VDC Termination Style Screw Weight 250g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes  Datasheet BA1 Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
$69.50
$82.01 inclGST