TX4L-U-D-D-2-96-N-N-N-N-N-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms
Mutirange Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 70 mm depth panel space
EC Compliant
Specification
Fastron Part Number
TX4L-U-D-D-2-96-N-N-N-N-N-N
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
4-20mA
Input
Multirange (refer to datasheet) TC/RTD, 0-50mA/0-50mV
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
96x96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
TX4L Series Instruction Manual
LEM APR 100 B420L, Split Core AC Current Sensor, selectable 50, 75, 100 Amp, True RMS 4-20mA output, Infinite Overload Capability
Compact and versatile Split Core AC current sensor, selectable 50, 75, 100 Amp True RMS 4-20mA output
Features
Split Core
True RMS output
4-20mA current output
Busbar, or Din Rail mounting
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for busbar/cable up to 18.5mm x 18.5mm
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
LEM Part Number
APR 100 B420L
Technology
AC Current Transformer with Process Output
ROHS
Yes
Supply Voltage
24VDC @ 30mA
Nominal Current (RMS + DC)
50,75,100 Amp Selectable
Overload
Infinite
Output
4-20mA True RMS
Isolation
5kV (AC, 50Hz, 1 min)
Bandwidth
30-2000Hz
Mounting Style
Din Rail mount or Busbar mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Spring Terminal Block (Female Included)
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
VX4-UMMA-A1, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, Relay Output, Relay Cooling 1 Alarm
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-UMMA-A1
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
N/A
Option 2
N/A
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Fastron Electronics GT-AV7-D-4, AC Voltage Transducer, 0-600V AC input, 22-60VAC/DC aux, 0-10V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV7-D-4
Control Output
0-10V Average RMS
Input
0-600VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM DHR 1000 C420, Hall Effect Current Sensor, 1000Amp , True RMS 4-20mA output
Compact and versatile transducers for high AC and DC currents from 100 to 1000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Panel mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀32mm
High isolation between primary and secondary circuits
Easy installation
Applications
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's. Current measurement gives faster response than temperature measurement
-Application Domain
Energy and Automation
Specification
LEM Part Number
DHR 1000 C420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Load Current (RMS + DC)
1000 Amp
Output
4-20mA
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
Level 3
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
260g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM LT 505-S, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +/-15...24VDC, X = 0.6%
Features
Bipolar and insulated current measurement up tp 1200 Amp
Current output
Bandwidth DC to 150kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 505-S
Technology
Closed Loop Hall Effect
Aperture
ø40.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/- 1200 Amp
Output
100 mA
Isolation
6 kV
Bandwidth
DC-150 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.6%
Termination Style
faston 6.3 x 0.8mm
Unit Weight
400g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM DVL 750 UI, Digital Voltage Transducer 750V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 750 UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 750V
Measurement Range
+/- 1125V
Output
4 - 20mA
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crydom Series 1 HD6050-10, Solid State Relay, Single Phase 3-32VDC Control, 50A, 48-660VAC Load, Random Crossing
Features
Ratings from 25A to 125 Amp @ 24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HD6050-10
Switching Type
Random Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
CY9008
CWD4890H
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom D1D20, Solid State Relay, DC 3-32VDC control, 20A, 100VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D1D20
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current
20 Amp DC
Surge Capability (10ms)
42 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See alternative D1D40 D1D40K with raised Gen 3 terminals or D1D80 for higher current alternative
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra Doo KC75-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 45, 75, 75 kVar, 100,000 Operations, AC-6B
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
Capacitor Duty
Discharge Resistors
Three-pole contactors
Seven ratings from 12,5 kVAr to 60 kVAr
IEC 60947-4-1 for AC-6b utilization category
UL Approved
Advantages :
Conforms to utilization category AC-6b
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Switching of capacitor bank in parallel without de-rating
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KC75-12-230-50
Functions
3 Pole Capacitor Duty Contactor
Nominal Voltage
230/480/600VAC @ 50Hz
Current Carrying Capacity as per UL
45kVar/Amp @230VAC, 75kVar/Amp@480VAC, 75kVar/Amp@600VAC, AC-6B
Auxiliary Contacts
1 x NO and 2 x NC
Trip Delay Time
2-10ms
Electrical Life
100,000 Ops
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000,000 Ops
Control Voltage
230VAC
Power Dissipation
6W
Approvals
UL
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
RODNV624010, Steel Teclom Enclosure IP55, AIR COOLED 578M3/h, RAL 7035 Gray, 2.0mm Galvanised Steel, Thermostat and Fan Pre-installed
Features
Thermostat Controlled Dual Fans for 578m3/h maximum flow rate
Lockable Door via Key
Stack multiple modules for larger Power Factor Correction Requirements
Optional HMI IP55 Door with Window RODNV624010
Specification
Fastron Part Number
RODNV624010
Function
Steel Water Proof Enclosure AIR COOLED
Configuration
Enclosure with Hinged Door, Key Lock and Fan and Thermostat
Air Flow Rate
578m3/h
Termination Style
Screw
Dimensions
L:950 x W:950 x H:1200mm
Weight
70kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
2.0mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP55
Operating Temperature
-20...55 °C
Datasheet
Datasheet