Fastron FRV 8-06/265, 127 to 265VAC L-N Voltage Monitoring Relay, 3 Phase 4 Wire Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Fixed 2s Timer Delay, Adjustable Upper and Lower Voltage Limits, Adjustable Asymmetry
FRV 8 Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase 4 wire mains
Features
Upper and lower level of monitoring voltage
Asymmetry
Adjustable time delay eliminates short voltage peaks and failures in the main
Supply is done from monitored voltage
Faulty state is indicated by red LED and by opening of output relay contact
Output contact 1 x Changeover / SPDT 10 A /250 V AC1
In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay
FRV8-06/460 - supply from all phases which means that relay is functional also in case when one phase is faulty
Variant FRV 8-04/265 - supply L1-N, means that relay monitors also failure of neutral wire
1-MODULE, DIN rail mounting
Specification
Technical Data
FRV 8
Supply and measuring
L1, L2, L3 (127,132,138,220,230,240,254,265VAC)
Supply terminals
L1, L2, L3
Supply/measured voltage
3 x 127-265 V (L-N) / 50 Hz
Level Umax
105 - 125 % Un
Level Umin
75 - 95 % Un
Burden
max. 2 VA
Hysteresis
2 %
Max. permanent overload
AC 3 x 265 V
Peak overload <1ms
AC 3 x 265 V
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
Number of contacts
1 x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE, CE
Datasheet
Product Datasheet
Fastron Monitoring/Time Relays Catalogue
For items in our catalogue which are not listed online please Contact Us for Possible Replacement
Application Notes
Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.
In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
LEM DVL 1000 UI Digital Voltage Transducer 1000V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Multi Range through pin selection
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 1000 UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 1000V
Measurement Range
+/- 1500V
Output
4 - 20mA
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Infineon DD700N22K Dual Diode Module
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
International standard package
3600V Isolation
60mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
Infineon Part Number
DD700N22K
Vrrm
2200V
Diode Configuration
Dual Diode Module
IF(av) @ 100 Deg C
700 Amp
Package Size
W:60mm L:144mm D:52mm
Itsm
22 kA
VF(to)
0.78V
Tj(max)
150°C
rF
0.185mΩ
Terminals
M10 Bolt
Hole Centres
80mm x 48mm (M6)
Gate Terminals
N/A
R th(j-c)
0.065°C/W
R th(c-h)
0.062°C/W
Weight
800g
Mounting Torque
6 Nm (12 Nm Terminals)
Factory Pack Qty
3
Certification
UL Listed, ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
See SKKD701/12 for possible alternative
Iskra Doo KNL90-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 90 Amps, 240VAC Coil
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL90-00-240VAC
Functions
3 Pole Contactor (3 x NO)
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
90 Amp Continuous @ 55 Deg C
Auxiliary Contacts
Optional BFX10-40, 4 Pole Snap On Aux Contacts
Trip Delay Time
2-10ms
Electrical Life
1,200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
15,000,000 Ops
Control Voltage
240VAC
Power Dissipation
9.4W per pole
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
1.25kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue
Fastron Electronics GA5-D-A6-D-N, 96x48mm 5 DIGIT DC Ammeter DC Voltmeter 4-20mA input, 22-60VAC/DC Supply
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
GA5-D-A6-D-N
Conditioner Output
N/A
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount (60mm depth)
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Varsi-Raycap V150E32 150VAC, 200VDC, E32 Package 250W Metal Oxide Varistor (MOV), Equivalent to Epcos SIOV-B32K150 Features
Features
High Energy Absorption Rating
Industry Standard Package
Wide Operating Range 35 - 1100VAC
High Peak Current Capability (70kA)
UL/CSA/ROHS/ISO9001:2015 Approved
Panel Mount
Screw Terminals
APPLICATION AREAS:
1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems).
2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes.
3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules.
Specification
Varsi-Raycap Part Number
V150E32
Operating Voltage AC (50-60Hz)
150V
Operating Voltage DC
200V
Average Power Dissipation
1.2W
Permissable Peak Current
25kA
Energy Absorption(2ms)
250W(max)
Tolerance(Vn)
+/- 10%
Termination Style
Screw
Weight
57g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CSA
Yes
Datasheet
Product Datasheet
Application Notes
Technical Blog MOV Article
GDT/MOV/TVS Tester
SPD Tester
Infineon D770N20T Rectifier Diode Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
41/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Infineon Part Number
D770N20T
Vrrm
600V
Diode Configuration
Diode Capsule (PUK)
IF(av) @ 85 Deg C
770 Amp
Package Size
ø41 x 14mm
Itsm
7.7 kA
VF(to)
0.81V
Tj(max)
180°C
rF
0.54mΩ
Gate Terminals
N/A
R th(j-c) (double sided cooled 180°sin)
0.057°C/W
R th(c-h) (double sided cooled)
0.015°C/W
Weight
75g
Clamping Force
3.8 - 7.6kN
Factory Pack Qty
12
Certification
ROHS
Infineon Headquarters
Germany
Datasheet
Product Datasheet
Alternatives
Contact Us for Possible Replacement
Heatsink
Heatsink Profiles
Iskra TRE 712 UNI 24-240 V AC/DC, Multifunction T1-T2 Time Relay, 1s - 500hrs, 24 - 240VAC/DC, Din Rail Mount, 3 x SPDT 8 Amp Relay
Features :
Multi-range (0.1s - 10 days)
Multi-voltage 12 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
3-wire PNP sensor compatible
Replaces TRE 702.1
Specification
Crouzet Part Number
TRE 712 UNI 24-240 V AC/DC
Function
Multifunction Time Relay
Nominal Voltage
24 → 240 V AC/DC
Digital Output
3 x C/O (SPST) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 1s - 500hrs
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Factory Pack Qty
1
Certification
CE
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Catalogue
Fastron Electronics FESCT-055-500-1-IP65, 500Amp Measurement, 1 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-055-500-1-IP65
Technology
Split Core AC Current Transformer
Ratio
500/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
500Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Vishay VSKL91/16, Dual Thyristor Module, Common Cathode 91 Amp, 1600V
Features
Thyristor for line frequency
Solder - Solder Bonded
Electrically insulated base plate
Industrial standard package
3600V Isolation
22mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Vishay Part Number
VSKL91/16
Vrrm
1600V
Diode Configuration
Dual Thyristor Module, Common cathode
IF(av) @ 85 Deg C
95 Amp
Package Size
W:22mm L:93mm D:30mm TO-240AA
Itsm
2.0 kA
VF(to)
1.1V
Tj(max)
125°C
rF
2.38mΩ
I(gt) @ 25 Deg C
150mA
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
Faston A2.8 x 0.8mm
R th(j-c)
0.22°C/W
R th(c-h)
0.1°C/W
Weight
75g
Mounting Torque
4 Nm (3 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Country of Origin
India
Datasheet
OLD Product Datasheet
2018 Product Datasheet
Alternatives
See TT92N16K or TT104N14K for Infineon Pressure Contact Alternative, or for IXYS solder bonded Alternative MCC95-16
Fastron Electronics FESCT-055-150-1-IP65, 150Amp Measurement, 1 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Features
Quick Release Split Core System
10m Flying Leads
ø 55mm
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurement, 1 Amp Outputs
Specification
Fastron Electronics Part Number
FESCT-055-150-1-IP65
Technology
Split Core AC Current Transformer
Ratio
150/5A
Aperture Size
ø 55mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Dimensions
180x138x52mm
Mounting Style
Panel Mount
Operating Temperature Range
-35°C / 55°C
Continuous Current (max)
150Amp x 1.2
Termination Style
10M Twisted Pair 0.34mm^2
Unit Weight
2000g
Factory Pack Qty
9