Rishabh CT 400/5 Class 1 30VA 62/30 (50), 400/5Amp 30VA, Class 1 Current Transformer HIGH BURDEN
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 400/5 Class 1 15VA 62-50/30 (50)
Technology
AC Current Transformer
Ratio
400/5
Aperture Size
28mm or 10x30mm Busbar
VA Rating
30VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
400Amp x 1.2
Termination Style
Screw
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
LEM HOP 500-SB/SP1 O/L Split Core Hall Effect Current Sensor, 500 Amp, +/-4V Output, 12.5 x 41mm Aperture, +/-12..15V Supply, Panel Mount, X = 2% Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 8kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical or Busbar Mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, nominal 200 to 600 A in one package.
Up to 900 A measurement range
Applications
Power supplies for TELECOM (monitoring and measurement)
Electrical chemistry
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Chopper
Battery supplied applications
Specification
LEM Part Number
HOP 500-SB/SP1
Technology
Open Loop Hall Effect
Aperture
104 x 40mm Square
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/-1000 Amp
Overload Rating
Contact Us for Possible Replacement
Output
+/-4 V
Isolation
3 kV
Bandwidth
DC-10 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 70°C
Accuracy
2%
Termination Style
Molex 5045-04A
Unit Weight
590g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crouzet Automation 84903020, Three Phase Voltage Control Relay, Phase Sequence or Phase Failure - 17.5 mm EMWS, 208-480 VAC, Self Powered
For Phase Sequence of Phase Failure Monitoring of AC Voltages up to 480VAC
Features:
Control Monitoring of AC voltages
Automatic recognition of AC
Measurement ranges from 288 V to 480 VAC
Choice between under and overvoltage
True RMS measurement
Selectable latching (memory) function
Specification
Crouzet Part Number
84903020 (Three Phase C-Lynx Voltage Monitoring Relay With SPDT Contacts)
Function
Phase Sequence/Phase Failure
Nominal Voltage
1 x 208 - 480 VAC/DC
Digital Outputs
1 x C/O Relays, 250VAC/DC @ 5 Amp
Min Breaking Current
10mA/5VDC
Delay on Threshhold Crossing
0.1 → 3s (0, +10%)
Delay on Pickup
600ms
Alarm Delay on Time (max)
200ms
Reset Time
1500ms
Adjustable Hysteresis
5 - 50% of Threshhold
Maximum Measurement Cycle Time
30ms/True RMS Measurement
Measurement Accuracy
1%
Supply Voltage Range
Same as Measurement 3 x 220 → 3 x 480 V ∿
Termination Style
Screw
Weight
170g
Certification
CE, UL, CSA, GL, ROHS
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Crydom DC400D20 DC Solid State Relays Crydom Part Number
Features
Ratings from 10A to 40 Amp @ 200/400VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DC400D20
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
20 Amp DC
Surge Capability (10ms)
42 Amp DC
Special Feature
IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
0 - 300VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
No direct equivalent Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
KW62B Water Cooler Block (Chiller) for Isolated Modules including IGBT & Diodes and SCR's Replacement to Semikron SKIW900/16
Replacement to Semikron SKIW900/16
1000 Amp RMS Output using TT500N16KOF
1100 Amp RMS Output using MCC552-16
Copper with Moulded Nickel Plated inlet and outlet, sealed.
Pressure Tested to 300 mbar
Thermal Rating based on 25 Deg C max inlet water temperature.
Type No
Litres/min
Device
Rcw deg C/W
mbar
kg
KW62B
2
50 x 92
0.055
50
1.2
4
50 x 92
0.042
190
Datasheet
Product Datasheet
Fastron Electronics F41F-1Z-C4-1 24VAC/DC SOCKET ONLY slimline with Spring Terminals for F41F Series Slim Relays
Features
6 Amp @ 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C4 Socket
Switching Type
250VAC or 30VDC Load
Control Input
1-36V AC/DC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Spring
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Suitable Parts
F41F-12-24Z
Fastron Electronics F41F-1Z-C2-4-240VAC, Slimline Relay F41F-60ZS and Socket F41F-1Z-C2-4 with Screw Terminals
Features
6 Amp @ 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C2-4-240VAC
Switching Type
250VAC or 30VDC Load
Control Input
220/240VAC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Fastron Electronics F41F-1Z-C4-4-240VAC, Slim Relay & Socket with Spring Terminals 220/240VAC Input, 6 Amp @ 30VDC/250VAC
Features
Multirange input 220/240VAC Nominal
Load Rating 6 Amp @ 30VDC/250VAC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed (Hongfa make)
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C4-4-240VAC
Switching Type
250VAC or 30VDC Load
Control Input
220/240VAC +/-10%
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Coils Power
12mA
Relay Type
Fastron FHF41F0224ZS
Termination Style
Spring Terminals
Unit Weight
60g
Factory Pack Qty
100
Datasheet
Datasheet
Fastron Electronics F41F-1Z-C2-4, Slimline SOCKET ONLY with Screw Terminals, for F41-60FZS for 220/240VAC Control
Features
6 Amp @ 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C2-4
Switching Type
250VAC or 30VDC Load
Control Input
220/240VAC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Suitable Parts
F41F-60ZS
Crydom ED06D5, EMR plug in Solid State Relay, 5-15VDC control, 5 Amp 1-48V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED06D5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
5-15VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies