Crydom ED10F5, EMR plug in Solid State Relay, 48-72VDC control, 5 Amp 1-80V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED10F5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
48-72VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 80VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/48VDC, 10 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals, 4400.0003 T11-211-10
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Threaded neck type
Thermal circuit breaker
1-pole - Power tools
Reset type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 500 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4400.0003 T11-211-10
Functions
1 Pole Thermal Circuit Breaker, Reset Type
Nominal Voltage
240VAC @ 50Hz or 48VDC
Nominal Current Range
10 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-5 to 60 Deg C
Insulation Resistance
500VDC
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
2kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
EM DVM 2000-UI Digital Voltage Transducer, Vpn = 2000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation
Features
Bandwidth DC to 13kHz
4-20mA Unipolar Analogue Output
Closed loop transducer using Hall effect
Digital Transducer (ASIC based)
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVM 2000-UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
24 VDC, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 2000V
Measurement Range
+/- 3000V
Output
4 mA at 0V, to 20mA @Vpn
Isolation
12 kV
Bandwidth
DC-13 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
375g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Rishabh DE96/50/5A, Moving Iron Ammeter, 50/5A, 96 × 96mm, Class 1.5
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 96 x 96mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DE96/50/5A
Nominal Measurement Range
0 - 50 Amp AC
Maximum Measurement Range
50 Amp
Over Range
Isn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Schurter 3-110-820, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 20 Amp, FMAD CP, 520VAC, Standard Attenuation, Low Leakage
Features
Schaffner FN 355-20-03 Drop In replacmeent
Line filter suitable for 3 Phase systems
Low Leakage
Wide Temperature Range
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Suitable for use in equipment according to IEC/UL 60950
Line filter suitable for low current Inverter such as PV or battery storage systems
Specification
Schurter Part Number
3-110-820
Rated Voltage
520V 3 Phase
Rated Current
20A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.005mA Medical Version
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
210g
Factory Pack Qty
4
Protection Class
Suitable for equipment according to IEC/UL 60950
Isolation
1.3 - 2.75kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Fastron FTCK-5-EGT-3000-B-INC-1/8" NPT EGT Vehicle Exhaust Sensor, Type K MIMS Class B, Inconel 600 80mm x 50mm x 4.8mm, 0 to 1100 Deg C
1/8" NPT Compression Fitting
Inconel 600 High Durability
Class A Accuracy
Teflon SS Braided Cable
Low Long Term Drift
Rated for 0 to 1100 Deg C Max
80mm x 50mm x 4.8mm
MIMS
Specification
Fastron Part Number
FTCK-5-EGT-3000-B-INC-1/8
Sensor Type
Type K Thermocouple
No of Wires
2
Probe Length
80 x 50mm
Sheath Thickness
4.8mm
Sheath Material
Inconel 600
Accuracy
Class A
Approvals
N/A
Cable length
3 Meters
Cable Type
Teflon/Braided Stainless Steel with Spring Bayonet Cap
Temperature Range
0 to 1100 Deg C
Special Feature
Quick Release Fitting, Strain Relief Spring Cable
Mounting Style
Quick Release Fitting
Weight
300g
Factory Pack Qty
1
Datasheet
Datasheet
Iskra Doo KNL38G-00 + NPLG, AC Contactor 240/400/500/690V, Overload 304(10s), 320(5s), 350(1s), 900(0.001s) (each pole), 24VDC Control Voltage, 3 Pole 3 x NO, Nominal Current = 38 Amps
Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity.
Features :
High contact reliability at low voltages
High electrical and mechanical endurance and high switching capacity
Four and Three-pole contactors
Optional auxiliary contacts
Ratings from 6 Amp to 1000 Amp
UL, CSA Approved
Advantages :
Saves costs of expensive replacement
Long electrical life
Reduces watt losses during “ON” condition, saves energy
High safety
No risk of dangerous voltage
Less maintenance and downtime
Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz
Specification
Iskra Doo Part Number
KNL38G-00 + NPLG
Functions
3 Pole Contactor with (3 x NO) with 1 x NO Aux Contacts
Nominal Voltage
230/400/500/690VAC @ 50/60Hz
Current Carrying Capacity as per UL
38 Amp Continuous @ 55 Deg C
Overload Capability
304(10s), 320(5s), 350(1s), 900(0.001s)
Auxiliary Contacts
1 x NO (+Optional Snap On 4 Pole NPL3)
Trip Delay Time
2-10ms
Electrical Life
200,000 Ops
Operating Temperature
-25 to 55 Deg C
Mechanical Operations
10.000,000 Ops
Control Voltage
24VDC
Power Dissipation
2.3W
Approvals
UL, CSA
Standards
IEC/EN 60947-4-1, AS/NZ 61009-1
Weight
200g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Contactor Catalogue
Iskra Contactor Catalogue