Crydom 3F20, 3 Phase, 1 Stage EMC (RFI) Line Filter for Power Modules and SSR
Features
Line filter in standard and medical version
1-stage - standard attenuation between 150-250kHz
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Spec
Sensata Part Number
3F20-4
Rated Voltage
475V rms
Rated Current
N/A
Filter Stages
1 Stage, 3 phase
Operating Temperature
-25°C to 100°C
Filter Type
Standard Attenuation
Leakage Current
0.45mA
Mounting
Panel Mount
Material
PolyCarbonate
Termination Style
Flying leads
Weight
80g
Factory Pack Qty
1
Protection Class
N/A
Isolation
N/A
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Fastron FRI 8-01/5, Current Monitoring Relay AC 0.5 - 5 Amp, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/5
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.5 - 5 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Fastron FRI 8-01/1, Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/1
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.1 - 1 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Fastron Electronics F41F-1Z-C2-1, Slimline SOCKET ONLY with Screw Terminals, for F41F Series Slim Relays
Features
Input Rated for 1-36 VDC
DIN Rail Mount
Changeover Contact
Ultra slim package
UL Listed
CE Compliant to IEC 60664
IP67
Specification
Fastron Part Number
F41F-1Z-C2-1 12-24VAC/DC Socket
Switching Type
250VAC or 30VDC Load
Control Input
1-36V AC/DC
Current @ Rated Voltage
6 Amp
Contact Arrangement
1 C/O (Single Pole Changeover)
Approvals
UL, CE
Dimensions
76.6 x 94.7 x 6.2
Ingress Protection
IP20
Relay Type
Fastron F41F Series
Termination Style
Screw
Unit Weight
50g
Factory Pack Qty
100
Datasheet
Datasheet
Suitable Parts
F41F-12-24Z
Fastron Electronics F13F-2P 12A + F13F-2Z-C4 240VAC Series Dual 12 Amp AC/DC Relay, 240VAc Coil
Features
2 x 12 Amp @ 250VAC or 30VDC
DIN Rail Mount
Changeover Contact
Compatible with Omron G2R-2-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Suits F13F 8 Pin Series Relays
Specification
Fastron Part Number
F13F-2P 12A 240VAC + F13F-2Z-C4
Switching Type
2 x 30VDC Load or 250VAC Load DPDT
No. of Pins
8
Approvals
CE, UL
Control Voltage
240VAC
Load Current
2 x 12 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Termination Style
PCB or Socket Mount
Unit Weight
38g
Factory Pack Qty
20
Suitable Relay
F13F-2P 12A 240VAC
F13F-2P 12A 24VDC
Fastron F157F-1Z-C3 Series SPDT 10/16 Amp Socket for AC/DC Relay, 6-230VAC/DC Coil
Features
Rated for 1 x SPDT 10/16 Amp @ 250VAC or 30VDC
5 Pin Socket for F157 Series
Changeover Contact
Slim package
Compatible with Omron G2R-1-S Series
UL Approved
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
F157F-1Z-C3
Switching Type
1 x SPDT 30VDC/250VAC C/O
No. of Pins
5
Approvals
UL, CE
Rated Coil Voltage
up tp 250VAC/DC
Rated Load Current
1 x 10/16 Amp (rms)
Special Feature
Optional LED Status Indicator
Mounting Style
PCB or Socket Mount
Load Voltage Range
0-250VAC, 0-30VDC
Isolation
2.5kV
Unit Weight
50g
Factory Pack Qty
20
Datasheet
Relay Datasheet
Relay Replacement
F157FT/24 1ZT
F157FT/250VAC 1ZT
Schurter 8020.5018 SHT 6.3 x 32mm 400VDC, 500VAC Time Lag T Fuse, UL 248-14 (10pcs)
Features
Pack of 10pcs
Suitbale Replacement for Muticomp CF06333CT/5/10
6.3 x 32 mm fuses for primary protection
16 rated currents from 0.5 A to 32 A
High rated voltages up to 500 VAC / 400 VDC
High breaking capacity up to 3.5kA @ 250VAC, 20kA @ 63VDC
Suitable for pulse-shaped continuous currents
Useable for commercial cooking appliances according UL 197
Designed for applications such as IEC/UL 60950
Applications
3-phase applications
DC applications
Photovoltaic
Frequency converter
Power electronics
Commercial cooking appliances
Specification
Schurter Part Number
8020.5018
Fuse Type
I²t Slow Blow
Nominal Voltage
400VDC, 500VAC
I²t Rating (Pre-Arcing)
271 A²/s
Nominal Current (DC)
5 Amp
Tested Breaking Capacity
1500 A @ 250 VAC, cos φ = 0.99 - 1
3500 A @ 400 VAC, cos φ = 0.7 - 0.8
Dimensions
6.3 x 32mm
Fuse Holder
Phoenix 3004171
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 85°C
Watt Loss
3W
DC Breaking Capacity
1000 A @ 400 VDC
20 kA @ 63 VDC
Unit Weight
3g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
TBC
Westcode-IXYS-Littlefuse DSAI17-16A, Avalanche Diode, 17 Amp, 1600V, 10/32"UNF, Cathode stud
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
Westcode-IXYS-Littlefuse Part Number
DSAI17-16A
Vrrm
1600V
Avalanche Diode Configuration
Cathode Stud
IF(av) @ 85 Deg C
17 Amp
Itsm
370 Amp
VF(to)
0.85V
Tj(max)
150°C
rF
10mΩ
Termination Style (No Tail)
2.2mm Solder Tab
Termination Style (Stud)
10 - 32 UNF
Tail Length to Stud
N/A
R th(j-c)
0.85°C/W
R th(c-h)
0.25°C/W
Weight
12g
Mounting Torque
2 Nm
Factory Pack Qty
50
Country Of Origin
USA
IXYS-Westcode Headquarters
USA
Datasheet
Product Datasheet
Obsolescence
This part is, Obsolete . Contact Us for Possible Replacement for replacmement
Crydom ED10F5, EMR plug in Solid State Relay, 48-72VDC control, 5 Amp 1-80V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED10F5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
48-72VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 80VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Schurter, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/48VDC, 10 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals, 4400.0003 T11-211-10
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Threaded neck type
Thermal circuit breaker
1-pole - Power tools
Reset type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
1kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 500 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4400.0003 T11-211-10
Functions
1 Pole Thermal Circuit Breaker, Reset Type
Nominal Voltage
240VAC @ 50Hz or 48VDC
Nominal Current Range
10 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-5 to 60 Deg C
Insulation Resistance
500VDC
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
2kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet