LEM LA 150-P Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 150kHz
Closed loop transducer using Hall effect
Compact and versatile
PCB Mounted with Strain Relief
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA150-P
Technology
Closed Loop Hall Effect
Aperture
13 x 8mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
106 Amp (150 Amp DC)
Measurement Range
+/-200 Amp
Output
53mA (75mA for 150 Amp DC)
Isolation
2.5 kV
Bandwidth
DC-150 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
35g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LES 15-NP, C/L Multi Range Hall Effect Current Sensor, 15 Amp, 2.5V ref in ref Out, PCB Mount, X = 2.25%, 4.3kV Isolation
Features
Closed loop current transducer
Voltage output
4.3kV Isolation
Frequency bandwidth 300kHz
Single supply + 5 V
Galvanic isolation between primary and secondary
Low power consumption
Compact design for PCB mounting
Vref IN Vref OUT
Multirange through PCB routing
Advantages
LTS footprint compatible
Zero insertion losses
Very good linearity
Very good dv/dt immunity
High immunity to external interference
Current overload capability
Optimised response time
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Solar inverters
Standards
IEC 61800-1: 1997
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007
IEC 62109-1: 2010
IEC 62477-1: 2012
UL 508:2013.
Application Domain
Industrial
Specification
LEM Part Number
LES 15-NP
Technology
Closed Loop Multirange Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
15 Amp
Measurement Range
+/-51 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-300 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
2.25%
Termination Style
PCB
Unit Weight
10g
Factory Packaging
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Alternatives
LTS 15-NP
Magnelab HCT-0010-020, Split Core DC Hall Effect Current Sensor, 20 Amp, +/-4V Output, Split Core 10mm Aperture, X = 1%
Features
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
Magnelab Part Number
HCT-0010-020
Technology
Split Core Open Loop Hall Effect
Aperture
ø10mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
20 Amp
Measurement Range
+/-30 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 75°C
Accuracy
1%
Termination Style
Flying Lead
Unit Weight
80g
Factory Pack Quantity
10
Datasheet
Product Datasheet
LEM LA 205-S Closed Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 100kHz
Closed loop transducer using Hall effect
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
LA205-S
Technology
Closed Loop Hall Effect
Aperture
18 x 23mm
ROHS
Yes
Supply Voltage
+/-12..15 VDC Bipolar, Isolated
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-300 Amp
Output
100mA
Isolation
3.25 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.8%
Termination Style
Molex series 5046 4 pins
Unit Weight
110g
Factory Pack Quantity
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYS 560-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 21.5 × 13 mm
Factory calibrated ● Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ● IEC 62109-1: 2010 ● UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYS 560-S-0100
Technology
Open Loop Hall Effect
Aperture
21.5 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
560 Amp
Measurement Range
+/-1400 Amp
Output
2.5 Vref
Isolation
5.4 kV
Bandwidth
DC-180 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
101g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HO 120-NP-0100 Series Open Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single power supply +5 V
Overcurrent detect 2.93 × IP N (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
Factory calibrated
Compact design for PCB mounting
Factory calibrated
Repositionable mounting foot
Dedicated parameter settings available on request
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 8 mm
Fast response
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-1: 1997
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007
IEC 62109-1: 2010
UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HO 120-NP-0100
Technology
Open Loop Hall Effect
Aperture
N/A
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
120 Amp
Measurement Range
+/-300 Amp
Output
2.5 Vref
Isolation
4.3 kV
Bandwidth
DC-350 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1.5%
Termination Style
PCB Through Hole
Unit Weight
32g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron F312 Series Proportional Phase Control Solid State Relay Controller
Proportional Phase Controller for SSR switching
Ratings from 25A to 90 Amp @ 90-600 VAC
Use any DC Control Solid State Relay
Use any Solid State Contactor
Instantaneous turn-on outputs
Specification
Fastron Part Number
F312 Series
Switching Type
Phase Angle or Burst (Selectable)
ROHS/CE/UL
Yes
Control Voltage
0 - 10V/0 - 5V/4 - 20mA/POT Input (at time of order)
Load Current
N/A based on SSR
Surge Capability
N/A based on SSR
Special Feature
Proportional Controller for SSR
Mounting Style
DIN Rail Mount
Load Voltage Range
90-415VAC
Dielectric Strength
4kV
Termination Style
Screw Terminal
Unit Weight
360g
Factory Pack Qty
20
Datasheet
Product Datasheet
F312 User Manual
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent Parts
Contact Us for Possible Replacement
F921 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm
Features
Isolated measurement of AC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned AC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F921-X-XX-AC-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Iskra Doo TSD 2 230VAC, Twilight Switch with Digital Time Clock, 230VAC +/-10% Power Supply, 8 Amp SPDT CO Relay
TSD 2 Series serves to monitor Light levels (10 - 50,000 lx) based on ditigal time clock settings, and provides Relay alarm output with digital adjustable timing function.
Features :
Timer overide feature for times when light is not reqtuired in the dark
Random Switching to Simulate Presence in House
Used to control lights on the basis of ambient light intensity
External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package)
Time Switch Control
Red LED output indication
2-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device
Control input for additional control, e.g. time switch, preswitch etc.
Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination
Supply voltage AC 230 V or AC/DC 12 - 240 V
Output contact: 1x changeover/ S
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Iskra Doo Part Number
TSD 2 230VAC
Voltage Range
AC 230 VAC
Operating Range
-15 %; +10 %
Light intensity sensing range
10 - 50,000lx
Time Adjustment
Digital Menu
Setting Accuracy
+/-1s per day at 23°C
Burden
max. 12 VA
Repeatability
1 %
Temperature Drift
0.1%/°C
Output
SPDT Relay 8 Amp
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
8 A / AC1
Breaking capacity
4000 VA / AC1, 384 W / DC
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
109 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet
Iskra Doo TSD 1 UNI, Twilight Switch, Universal 12-240VAC/DC Power Supply, 16 Amp SPST CO Relay
TSD 1 Series serves to monitor luminance from 1 to 50,000lx, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Used to control lights on the basis of ambient light intensity
External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package)
Red LED output indication
1-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device
Control input for additional control, e.g. time switch, preswitch etc.
Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination
Supply voltage AC 230 V or AC/DC 12 - 240 V
Output contact: 1x changeover/ S
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Iskra Doo Part Number
TSD 1 UNI
Voltage Range
AC 12 - 240 VAC/DC
Operating Range
-15 %; +10 %
Current Range
0.05 - 5 A (AC 50 Hz)
Trip Adjustment
Potentiometer
Setting Accuracy
30 %
Burden
max. 12 VA
Repeatability
1 %
Temperature Drift
0.1%/°C
Peak Overload (10s)
100 Amp
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Luminance range
2 Ranges 1-100lx, 100-50,000lx
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
16 A / AC1
Breaking capacity
4000 VA / AC1, 384 W / DC
Inrush current (3s)
30 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
109 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet
Advanced Energy Thyro S 3S Series Three Phase SCR Power Controller, 16-1500Amp, 400VAC, Phase(VAR), Burst(TAKT), SWITCH Operating Modes. Compatible Replacement for Eurotherm
Features
400VAC +10/-57% Line to Line Voltage, Current or Power Control
Smallest footprint on the market
Built in Fuses
3 Phase, Phase Angle & Burst Controller with SWITCH operation mode
SWITCH between Phase(VAR) or Burst(TAKT) control modes
(0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control
Removable Cover
USB Configuration/Bias Setting
Potentiometer Adjustments
Synchronisation Function for Multiple TAKT Sync
Applications
Electrical Ovens, Kilns, or Furnaces
Primary Control of Transformer Loads in Phase or Burst Fire mode
Resistive Loads up to 6:1 Hot/Cold Ratio
AC Soft Starter (VAR Mode Combined with PLC)
Power Regulation Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for extreme environments such as mining
Series Optional Features
For HRL
Current Control/Feedback
Programmable Relay Alarm Output
Load Monitoring
Analogue Output
For HRLP
As above with Power Control Feedback
Communication Options
Standard Thyro Bus Module
BasicBus Module
Specification
Advanced Energy Part Number
Thyro S 3S 400VAC or Thyro S 3S 500VAC
Approvals
CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC
Control Accuracy
3% at rated voltage
Rated Operating Temperature
45°C
Temperature Derating
0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C
SCR Configuration
Single Phase AC Switch
Control Modes
Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request)
Control Input
4(0)-20mA, 0(1)-5V, 0(2)-10V, POT
Load Current
16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max)
Control Range
0-100%
Options
Conformal Coating for Gas or High Humidity Environments
Mounting Style
Panel Mount
Supply Voltage Range
400VAC +10/-15% (-57% with 24VDC Aux Supply)
Soft Start
Via PLC input
Termination Style
Screw
Unit Weight
2.1 to 74kg
Factory Pack Qty
1
Technical Docs
Brochure
User Manual
2 Leg Control Application Blog
Thyro A Series Quick Installtion Guide
Setting Up Comms on Thyro A Series Controllers
Anybus Device Ethernet IP Setup Guide
Fastron FRB8-01, Twilight Switch, Universal 110-240V Power Supply, 16 Amp SPST CO Relay
FRB8-01 Series serves to monitor luminance from 1 to 100,000lx, and provides Relay alarm output with Hysteresis
Features :
Used to control lights on the basis of ambient light intensity
External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package)
Red LED output indication
1-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device
Control input for additional control, e.g. time switch, preswitch etc.
Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination
Supply voltage AC 100- 240 V
Output contact: 1x changeover/ S
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Iskra Doo Part Number
FRB8-01
Voltage Range
AC 12 - 240 VAC/DC
Operating Range
-15 %; +10 %
Current Range
0.05 - 5 A (AC 50 Hz)
Trip Adjustment
Potentiometer
Setting Accuracy
30 %
Burden
max. 12 VA
Repeatability
1 %
Temperature Drift
0.1%/°C
Peak Overload (10s)
100 Amp
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Luminance range
2 Ranges 1-100lx, 100-50,000lx
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
16 A / AC1
Breaking capacity
4000 VA / AC1, 384 W / DC
Inrush current (3s)
30 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
109 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet