Fastron Electronics HF121-12/0.4-25-7%K, 25kVar 400VAC(1.53mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.53mH(400VAC) 2.457mH(525VAC)
Specification
Technical Features
HF121-12/0.4-25-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
1.53mH
Inductance (mH @ 525VAC)
2.457mH
Nominal Power
25kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
30kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Electronicon 275.196-505500/221K02, Power Factor Correction Capacitor, 3 Phase, 136 x 230mm, Feed Through Terminals, Dry Type (Gas Filled), 660VAC, 3 x 55.2uF, REQUIRES EXTERNAL DISCHARGE RESISTORS
Characteristics and utility
25kVar @ 690V @ 50 Hz
33.3kVAr @ 800V @ 50Hz
Three phase capacitor DUAL WINDING internally delta connected
External Discharge Resistors Required
Reactive power factor correction
Dry type
Feed Through Terminals Capagrip L (3 x 56 Amp Max)
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
UL 94 V0 Resin
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Vishay Part Number
275.196-505500/221K02
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
136 x 230mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
800V @ 50Hz
Kvar
25 Kvar
Capacitance
3 x 55.2uF (12.5KVAR @ 415VAC 50Hz) (25KVAR @ 690VAC 50Hz) (33,3KVAR @ 800V 50Hz)
Tolerance On Capacitance
-5% + 10% (others on request)
Current (Imax)
3 x 36 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Capacgrip L (Feed Through 3 x 56 Amp)
Unit Weight
2.9kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
H10 Heatsink Profile 110mm x 240mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Oztherm F430 Series 2 Leg SCR Burst Controller Spare Card Set
100% Australian Made
3 Phase Burst Controller
4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control
Fully enclosed IP20
Burst Fired switching
Aluminium Frame
Removable perspex Cover
Applications
Electrical Ovens, Kilns, or Furnaces
Secondary or Direct Control only
Controlled Power Applications
Electric Boilers
Smelting of Raw Metals
Suitable for extreme environments such as mining
Room/Chamber heating
Available Options
Current Limit and Trip AC (C)
Phase Loss Output (PH)
Partial Load Failure (PLF)
Loose Semiconductor Fuses (F)
Internal Semiconductor Fuses (FI)
Thermal Overlad Protection (T)
Special Features
Contact Us for Possible Replacement for customised features
Specification
Oztherm Part Number
F430 Series 2 Leg Burst Controller (Cards Only)
Rated Operationg Temperature
50°C
SCR Configuration
3 Phase AC Swtich
Control Voltage
4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)
Load Current
30 - 120Amps Per Phase
Control Range
0-100%
Special Feature
(Optional) Current Limit & Trip AC, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses
Mounting Style
Panel Mount
Supply Voltage Range
380-440VAC +/-10%
Soft Start
1-20mS
Termination Style
Screw
Unit Weight
up to 3kg
Factory Pack Qty
1
Datasheet
F430 Brochure
F430 Installation and Commissioning Manual
Fastron FTPS-3-400-40-420, SCR Phase/Burst Controller, 400VAC 3 Wire (400V L-L, 230V L-N), 3 Phase, 4-20/0-20mA/5K POT Input, with In built Fuses, 32 Amps per Phase @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, Phase Angle/Burst Controller
4-20mA Input Proportional Control (0-10V/1-5V/5K POT input on request)
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FTPS-3-400-40-420
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA default (0-10V/0-5V/5K POT on request)
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contact (not available with RS485 Option)
Comms
Optional RS485 Modbus RTU
Special Feature
Internal Fuse
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Delay on Start
Programmable from 0 to 10 seconds
Soft Start
Programmable from 0 to 10 seconds
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Modbus Register Map
Calibration Procedure
Wiring Detail
KW62B-With Plate, 130mm long water cooler block (Chiller) for Isolated Modules including IGBT & Diodes and SCR's
M7 Holes for Mounting to Plate.
Replacement to Semikron SKIW900/16
1000 Amp RMS Output using TT500N16KOF
1100 Amp RMS Output using MCC552-16
Copper with copper Binded inlet and outlet, sealed
Pressure Tested to 300 mbar
Nickel plated copper solid construction with aluminium mounting plate
Thermal Rating based on 25 Deg C max inlet water temperature.
Type No
Litres/min
Device
Rcw deg C/W
mbar
kg
KW62B
2
50 x 92
0.055
50
1.2
4
50 x 92
0.042
190
Datasheet
Product Datasheet
P8/150M, H8 Heatsink, 150mm Long Milled Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Fastron Electronics HF121-12/0.4-50-7%K, 50kVar 400VAC(0.76mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.76mH(400VAC) 1.229mH(525VAC)
Specification
Technical Features
HF121-12/0.4-50-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH) @ 400VAC
0.76mH
Inductance (mH) @ 525VAC
1.229mH
Nominal Power
50kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
38kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
H81 Heatsink Profile 72mm x 150mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data