Fastron FRE-440-80C-M, SCR Burst Controller, 400VAC 3 Wire 3 Leg (400V L-L, 230V L-N), 3 Phase, 4-20/0-5V/0-10V Input, 65 Amps per Phase @ 40 Deg C, Fan Cooled
Features
Burst Control Function
3 Phase, or Single Phase, Burst Controller
0-10V/0-5V/4-20mA Input Proportional Control
Fully enclosed IP20
Aluminium Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FRE-440-80C-M
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Mode
Burst Fire Control
Control Voltage
0-10V/0-5V/4-20mA
Load Current
65 Amps Per Phase @ 40 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO , 1 x NC Relay Contacts
Comms
NA
Special Feature
Load Monitoring, Overtemperature Alarm, Load Break Alarm, Fan Cooled (Includes mounted fan)
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Delay on Start
NA
Soft Start
NA
Termination Style
Screw
Unit Weight
1kg (2kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Modbus Register Map
Calibration Procedure
Wiring Detail
Fastron Electronics HF121-12/0.4-40-7%K, 40kVar 400VAC(0.95mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 0.95mH(400VAC) 1.526mH(525VAC)
Specification
Technical Features
HF121-12/0.4-40-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
0.95mH
Inductance (mH @ 525VAC)
1.526mH
Nominal Power
40kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
25kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
H4 Heatsink Profile 33mm x 98mm, Various Lengths cut to order, Milled or Raw Finish
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Fastron FY3 Series, Phase/Burst Controller for Primary Control of Transformer (Phase angle mode only), Voltage/Current/Power Limit Modes, For 3 Wire or 4 Wire Loads, 400VAC, 50 Amps per Phase @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/0-10V/1-5V input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FY3 Series
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V
Load Current
50-500 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Soft Start
N/A
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
Brochure
User Guide
Modbus Protocol Guide
Modbus Register Map
Video for How to Set Current/Voltage/Power limit
Fastron Electronics HF121-12/0.4-12.5-7%K, 12.5kVar 400VAC(3.06mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 3.06mH(400VAC) 4.914mH(525VAC)
Specification
Technical Features
HF121-12/0.4-12.5-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
3.06mH
Inductance (mH @ 525VAC)
4.914mH
Nominal Power
12.5kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
21kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Fastron FRE-440-80C-M, SCR Phase Angle Controller, 400VAC 3 Wire 3 Leg (400V L-L, 230V L-N), 3 Phase, 4-20/0-5V/0-10V Input, 65 Amps per Phase @ 40 Deg C
Features
Phase Angle Control Function
3 Phase, Phase Angle Controller
0-10V/0-5V/4-20mA Input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
FRE-440-80P-M
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Mode
Burst Fire
Control Voltage
0-10V/0-5V/4-20mA default
Load Current
65 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO, 1 x NC Relay Contacts
Comms
NA
Special Feature
Load Monitoring, Overtemperature Alarm, Load Break Alarm, Fan Cooled (Fan included)
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Delay on Start
NA
Soft Start
NA
Termination Style
Screw
Unit Weight
1kg (2kg Packed)
Factory Pack Qty
1
Technical Docs
Datasheet
User Manual
Iskra Doo KNK3053 50 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF
Characteristics and utility
50kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - Feed through terminals
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
UL 94 V0 Resin
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Iskra Part Number
KNK3053 50 KVAR 525V 50HZ
Technology
Dry Type, Low Loss, Self Healing
Dimensions
136 x 285mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
50 Kvar
Capacitance
3 x 192.48uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
36 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
4.2kg
Factory Pack Quantity
25
Datasheet
Iskra PCF Catalogue
Capacitor Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Voltage Derating Tables
Hot Spot Testing
25kvar Specification Sheet
40kvar Specification Sheet
Fastron T6-2-4-75Z (60), 3 Phase, 2 Leg SCR Burst Controller, 400VAC with In built Fuses, 32 Amps per Phase @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/0-10V/1-5V/5K POT input Proportional Control
RS485 Modbus RTU as standard
2 x Analogue Outputs as standard
Limit POT input for output limitation
C/O Alarm Contacts
Start/Stop Run Feature
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heatsing
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
T6-2-4-75Z (60),ST6-2-4-40Z (32),T6-2-4-50Z (40)
Rated Operating Temperature
50°C
SCR Configuration
3 Phase, 2 Leg, AC Switch
Control Voltage
4-20mA/0-10V/0-5V/5K POT
Load Current
40 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x C/O Relay Contacts
Special Feature
Internal Fuse
Analogue Output
2 x Programmable Outputs (3 Phase), 1 x Programmable Output (Single Phase)
Comms
RS485 Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Soft Start/Stop
Programmable
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Vishay PhMKPg525.3.20,00-84, Power Factor Correction Capacitor, 3 Phase, 85 x 265mm IP00 Dry Type (Gas Filled), 20KVAR @ 525VAC, 12.5KVAR @ 415VAC, 3 x 77uF
Characteristics and utility
20kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
UL 94 V0 Resin
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Vishay Part Number
PhMKPg525.3.20,00-84
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
85 x 265mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
20 Kvar
Size
85 x 265mm
Capacitance
3 x 77uF (12.5KVAR @ 415VAC)
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
22 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
1.7kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
8304/277R Heatsink Profile 300mm x 84mm x L277mm, Rth =0.145 °C per Watt @ 300mm
Datasheet
Product Datasheet
Heatsink Data
New Heatsink Data Book
Old Heatsink databook with additional thermal data
Fastron Electronics HF121-12/0.4-40-14%K, 40kVar 400VAC 14% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.92mH(400VAC) 3.071mH(525VAC)
Specification
Technical Features
HF121-12/0.4-40-14%K
Electrical
Voltage
400V System/525V Capacitor
Network Frequency
50/60Hz
Nominal Power
40kvar
mH Rating
1.92mH(400VAC) 3.071mH(525VAC)
Value of p%
14% (134 / 160Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
38kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide