HS211 + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps
Free Aus Post Shipping for $300 SpendHS211 + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps 4-20mA Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Specification Part Number HS211 + RS1API420MA280025R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 240 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style DIN Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A_B HS211 RS1A Series Product Notifications Pease note Changes from Gen 3 to Gen 4 (current) package design here
-
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-20 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-20-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-20 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
FTCK-Transmitter-0-300-420-24, Type K , 4-20mA Transmitter, 0 to 300 Deg C, 24VDC Supply
Fastron Type K Thermocouple FTCK-Transmitter-0-300-420-24, Type K , 4-20mA Transmitter, 0 to 300 Deg C, 24VDC Supply Class A Accuracy Steel Insulated Cable Low Long Term Drift Rated for 0 to 220 Deg C Max Spring Cable Connection 60mm Jaw Clip Specification Fastron Part Number FTCK-Transmitter-0-300-420-24 Sensor Type Type K to 4-20mA Transmitter No of Wires 2 Shaft Length N/A Shaft Thickness N/A Accuracy Class A Temperature Range 0 to 300 Deg C Span/ Zero Adjustment YES Weight 50g Factory Pack Qty 1
$15.00
$17.70 inclGST -
E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series
Elite E500M-3012, 3 Analogue Output Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$149.00
$175.82 inclGST -
FRS4-C40/350VAC (R), 4 Pole, Un = 240VAC, Uc = 350VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With Remote Contacts
Free Aus Post Shipping for $300 SpendTrent FRS4-C40/350VAC (R), 4 Pole, Un = 240VAC, Uc = 350VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With Remote Contacts Specifications Trent part number FRS4-C40/350VAC (R) Nominal Voltage (Un) 240VAC Maximum Operating Voltage (Uc) 350VAC Voltage Protection Level (Up) <1.75kV No of Poles 4 Category IEC / EN / VDE Class II / Type 2 Location of use Sub Distribution Boards Protection modes L-L L-PE, High Energy MOV Additional Remote Contacts YES (1 x CO) Protective element MOV Surge discharge rating Imax up to 40kA(8/20us) L-PE/L-L 350VAC / 20kA(8/20us) L-PE/L-L Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
FRS4-C40 320V 2P (2+0) (R), Class II/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 20/50kA L-N, 230VAC, DIN Rail Mount, L/N-PE, High Energy MOV Type
Free Aus Post Shipping for $300 SpendTrent FRS4-C40 320V 2P (2+0) (R), Class II/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 20/50kA L-N, Un = 230VAC, Uc = 320VAC, DIN Rail Mount, L/N-PE, High Energy MOV Type Specifications Trent part number FRS4-C40 320V 2P (2+0) (R) Nominal Voltage (Un) 230VAC Maximum Operating Voltage (Uc) 320VAC Voltage Protection Level (Up) <1.5kV No of Poles 2 Category IEC / EN / VDE Class II / Type 2 Location of use Sub Distribution Boards Protection modes L/N-PE, High Energy MOV Additional Remote Contacts YES Protective element MOV Surge discharge rating Imax up to 40kA(8/20us) L/N-PE 320VAC Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
-
FRS2-C40-800R, 800VDC 2 Pole Surge Protection Device for DC/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS2-C40-800R, 750VDC Surge Protection Device for DC/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS2-C40-800R Nominal Voltage (Un) 800VDC Maximum PV Operating Voltage (Ucpv) 960VDC Voltage Protection Level (Up) <3.6kV No of Poles 2 + 0 Category IEC / EN / VDE Type 2 (Class II) Location of use Battery/Solar System/UPS Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 400g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$69.00
$81.42 inclGST -
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420-24, DC Current Transducer, 0-5 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-5 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-5A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-5 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-015-420B-24, DC Current Transducer, +/-15 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-15 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FRS2-C40-1500R, 2 Pole 1500VDC Surge Protection Device for DC/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
FRS2-C40-1500R, 2 Pole 1500VDC Surge Protection Device for DC/Solar Systems, Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS Specifications Trent part number FRS2-C40-1500R Nominal Voltage (Un) 1500VDC Maximum PV Operating Voltage (Ucpv) 1800VDC Voltage Protection Level (Up) <5.2kV No of Poles 2 Category IEC / EN / VDE Type 2 (CLass II) Location of use Battery/Solar System/UPS Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES NO/NC/COM Protective element MOV No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 400g Standards IEC614643-31:2018 (TUV, CE Approved) Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$79.00
$93.22 inclGST -
FBS RK 24 ST-II, Slim Surge Protection Device For RS485, 2 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module
FBS RK 24 ST-II, Slim Surge Protection Device For RS485, 2 Pole, 24VDC, 5kA per line @ Imax(8/20uS)(KA), -40 to +80 Deg C Operation; YD/T 1542, Nominal Discharge 5kA, Maximum Discharge 10kA, LPZ 1 -2 or higher, Slim 7mm Wide Module Application IT Systems Coarse and FIne Protection Industrial Control System Measurement System Device Control Specifications Trent part number FBS RK 24 ST-II Nominal Voltage 24VDC No of Poles 4 Category IEC / EN / VDE LPZ 0 -2 or higher Location of use IT Communications Line/signals Protection modes TX+/TX-/RX+/RX-/GND Additional Remote Contacts N/A Protective element MOV No Fault/Fault Indication N/A Surge discharge rating Per pole 5kA (8/20uS)9KA) Max, 10kA (8/20uS)9KA) Nominal Internal protection and safety Thermal disconnector in each MOV Weight 50g Standards IEC61643-21; GB 18802.21 ; YD/T 1542 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$49.00
$57.82 inclGST -
Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor 16 - 1500Amp 400VAC +10/-15% Burst(TAKT) Fire Mode, Economical Firing Mode
Advanced Energy Thyro S 2S Series 2 Leg 3 Phase Solid State Contactor, Burst(TAKT)Firing Mode Only. Compatible Replacement for Eurotherm Features 400VAC +10/-57% Line to Line Voltage, Current or Power Control Smallest footprint on the market Built in Fuses 3 Phase, 2 Leg Economical Burst Controller Firing Mode (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover USB Configuration/Bias Setting Potentiometer Adjustment Synchronisation Function Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode Resistive Loads up to 6:1 Hot/Cold Ratio AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 2S 400VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes 2 Leg Burst(TAKT) for low dissipation Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 400VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 74kg Factory Pack Qty 1 Technical Docs Brochure User Manual 2 Leg Control Application Blog Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$1,266.46 - $7,229.20