DTC1-S/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 12VDC SSR Output, RS485 Modbus RTU
Free Aus Post Shipping for $300 spendFastron DTC1-S/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 12VDC SSR Output, RS485 Modbus RTU Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M-C5 Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
VX2-UCMD-A2CTD4H2R, Temp Controller, 48x96mm, 24VAC/DC, Multirange Input, 4-20mA Output, Relay Cooling Output, 2 Alarms, Retransmission, Event Input (2x SV), Remote Setting Input, Current Feedback
VX2-UCMD-A2CTD4H2R, Temp Controller, 48x96mm, 24VAC/DC, Multirange Input, 4-20mA Output, Relay Cooling Output, 2 Alarms, Retransmission, Event Input (2x SV), Remote Setting Input, Current Feedback Multirange Input (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP65 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number VX2-UCMD-A2CTD4H2R Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals. Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2 x Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 Event Input (2x SV), 4-20mA Remote Setting Input, Retransmission, Current Feedback Mounting Style 48 x 96mm Panel Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 350g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet VX Series Brochure VX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual USB Driver (Windows 7) Not required for Windows 10 or 11
$271.00
$319.78 inclGST -
DTC1-A/M1-2I, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, 24VAC/DC, 4-20mA output
Free Aus Post Shipping for $300 spendFastron DTC1-A/M1-2I, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, Pt100 Input Jumper Setting, 24VAC/DC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M1-2I Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Input Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
Thyro S 1S Series Single Phase SCR Controller 16 - 1500Amp 500VAC Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes
Advanced Energy Thyro S 1S Series Single Phase SCR Power Controller, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), SWITCH Operating Modes. Compatible Replacement for Erutotherm Features Optional Profinet,Profibus,Ethernet,Modbus Comms 500VAC +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro S 1S 500VAC Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1500 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 500VAC +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installtion Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$932.50 - $2,882.00
-
FTA-020-420B-24, DC Current Transducer, +/-20 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-020-420B-24, DC Current Transducer, +/-20 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-020-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-20 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
DTC1-A/M-2I, DIN Rail Mount Temperature/Humidity Controller, Multirange Thermocouple Input, 85-265VAC, 4-20mA output
Free Aus Post Shipping for $300 spendFastron DTC1-A/M-2I, DIN Rail Mount Temperature/Humidity Controller, Multirange Thermocouple Input, 85-265VAC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-2I Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Input Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
Thyro Tool Pro Software CDROM - Software for Advanced Energy SCR Controller
Free Aus Post Shipping for $300 SpendSoftware for Advanced Energy SCR Controller For setting up Communication addresses via USB and configuring SCR Controllers Locally or remotely. Highly valueable for controller diagnostics, fault finding and communication validation. Basic Bus User Manual Thyro A Series Quick Installtion Guide
-
HS211A-DR + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps, Panel Mount
HS211A-DR + RS1API420MA280025R, Single Phase Proportional Phase Controller with Heatsink, 4-20mA Input, 240V, 25 Amps, Panel Mount 4-20mA Proportional Phase Control Input Ratings from 25A to 80 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Specification Part Number HS211A-DR + RS1API420MA280025R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4-20mA Proportional Input Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 240 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style DIN Rail Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211A_B HS211 RS1A Series Product Notifications Pease note Changes from Gen 3 to Gen 4 (current) package design here
$145.00
$171.10 inclGST -
DTC1-S/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Thermocouple Input, 24VAC/DC, 12VDC SSR Output, RS485 Modbus RTU
Free Aus Post Shipping for $300 spendFastron DTC1-S/M1-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Thermocouple Input, 24VAC/DC, 12VDC SSR Output, RS485 Modbus RTU Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M1-C5 Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
DTC1-S/M1-PROG, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, 24VAC/DC, SSR 12VDC Output output
Free Aus Post Shipping for $300 spendFastron DTC1-S/M1-PROG, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, Pt100 Input Jumper Setting, 24VAC/DC, SSR 12VDC Output output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M1-PROG Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/PT100/Cu50/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options 60 Step Program Control Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
DTC1-S/M-PROG, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 12VDC SSR Output
Free Aus Post Shipping for $300 spendFastron DTC1-S/M-PROG, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 12VDC SSR Output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-S/M-PROG Control Output SSR 12VDC@30mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options 60 Step Program Control Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
DRH3P60A20, 20 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO)
Free Aus Post Shipping for $300 SpendCrydom DRH3P60A20, 20 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, Configuration_Auxiliary 2 x SPST (2 x NO) Features 20 Amp AC Semiconductor Motor Controller Load voltage range up to 600VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Spec Crydom Part Number DRH3P60A20 Switching Type Zero Crossing Approvals ROHS,CE,ULIEC Control Voltage 90-280VAC Transient Voltage 1200V Load Current (per phase) 20 Amp (rms) Surge Capability (10ms) 716 Amp (peak) Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 48-600VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 197g Factory Pack Qty 20 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies