Search results for "비대면유심개통문의 gora43430aa 소액대출50만원내구제 고라통신 선불유심 현금화 정식업체 무서류간편대출 은평구 24시 당일소액급전대출"
-
NBR-A070UD33LI630, Semiconductor Fuse, 630 Amp, 690VAC, Size_Body Size 33 Type KI, 200kA with Indicator and Microswitch
Free Aus Post Shipping for $300 SpendTrent NBR-A070UD33LI630, Semiconductor Fuse, 630 Amp, 690VAC, Size_Body Size 33 Type KI, 200kA with Indicator and Microswitch Features Square Body Size_Body Size 33 Type KI Wide Range of I²t Ratings up to 2000 Amp Busbar or Fuse Holder Mounted IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Fuse Blown Indicator and Microswitch Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number NBR-A070UD33LI630 Fuse Type I²t AR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (660V) 230000A²/s Nominal Current (RMS + DC) 630 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 134 x 73 x 78.5mm Hole Centers 91.5mm +/- 16.1mm Mounting Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watts Dissipation 120W Termination M10 Unit Weight 900g Factory Pack Qty 10 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$305.00
$359.90 inclGST -
Rish DPM 96x96 A DC-420-24, 96x96mm DC Ammeter, Panel Mount, 4-20mADC Input, 24VDC Aux Supply, 4.1 Digit 0-19999 range
Free Aus Post Shipping for $300 SpendRishabh Instruments Rish DPM 96x96 A DC-420-24, 96x96mm DC Ammeter, Panel Mount, 4-20mADC Input, 24VDC Aux Supply, 4.1 Digit 0-19999 range Default display is mA, for other dsiplay parameter please advsie Features Adjustable Zero and Span Setting Adjustable Display Scaling Large 4.1 Digit 20.3mm (8 Inch) LED Display 250mS Response Time PC 94 UL V0 Each unit needs just 96 x 96mm Panel Space 55mm Depth CE Approved Specification Rishabh Part Number Rish DPM 96x96 A DC-420-24 Conditioner Output N/A Input 4-20mA Over Range x 1.5 Operating Temperature 0 - 60°C Supply Voltage 24VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Display Type 4.1 Digit RED LED Mounting Style 96 x 96mm (xD55mm)Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1 Datasheet Product Datasheet Application Notes Panel Meters Blog Articles
Free Aus Post Shipping for $300 Spend$129.00
$152.22 inclGST -
EM94-Z-V1-L-Z, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 10-60VDC, Single Line LCD Display,12-60V DC Aux Supply
Free Aus Post Shipping for $300 spendRisbabh EM94-Z-V1-L-Z, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 60-300VDC, Single Line LCD Display,12-60V DC Aux Supply, Internal Logging 2 Pulse/Alarm Outputs 50-150mV Shunt Input, and nominal voltage 60-300VDC RS 485 communication up to 57,600 bit/s USB Port 8MB Internal Storage DC Measurement Only The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.5 Simple Menu RS 485 communication up to 57,600 bit/s USB Comms 8MB Internal Logger 60-300VAC/DC power supply Specification Rishabh Part Number EM94-Z-V1-L-Z Functions kWh Meter, Energy Meter Supply Voltage 60-300VAC/DC Nominal Measurement Range 60-300VDC Maximum Measurement Range 60-300VDC Display Single Line LCD Pulse/Relay Output 2 Accuracy Class 0.5 (Energy) USB YES Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS485 Modbus RTU YES 57,600bps Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Free Aus Post Shipping for $300 spend$199.00
$234.82 inclGST -
FESCTHY-3000-1250-100mV, 1250Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCTHY-3000-1250, 1250Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-3000-1250 Technology Split Core AC Current Transformer Ratio 1200/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1250Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST -
FESCT-3000-1500-100mV, 1500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCT-3000-1500, 1500Amp 100mV Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCT-3000-1500 Technology Split Core AC Current Transformer Ratio 1500/100mV Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mVAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1500Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST -
FESCTHY-3000-1500-100mA, 1500Amp 100mA Class 1 Measurement Split Core CT's, 1M Flying Leads, HY2.0 Connection, 76x127mm Aperture
Fastron Electronics FESCTHY-3000-1500, 1500Amp 100mA Class 1 Measurement Split Core CT's, 1M Flying Leads, 76x127mm Aperture Features Quick Release Split Core System 1m Flying Leads Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FESCTHY-3000-1500 Technology Split Core AC Current Transformer Ratio 1500/100mA Aperture Size 76x127mm VA Rating N/A Accuracy Class Class 1 Output 100mAAC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 55°C Continuous Current (max) 1500Amp x 1.2 Termination Style Terminals Unit Weight 3000g Factory Pack Qty 9 Datasheet Product Datasheet Installation Guide FESCTHY Install Guide
$208.00
$245.44 inclGST -
GMTA-DV7-D-RN, DC Voltage Transducer with Alarm, 0-600VDC Input, 22-60VAC/DC Aux, 1 x Relay Alarm
GMTA-DV7-D-RN, DC Voltage Transducer with Alarm, 0-600VDC Input, 22-60VAC/DC Aux, 1 x Relay Alarm Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint. Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Part Number GMTA-DV7-D-RN Control Output 1 x SPST Alarms 3 Amp Input 0-600VDC Alarm Type 1 x SPST NO Relay 3 Amp Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$303.00
$357.54 inclGST -
P195BDA, MiniTactor Contactor SPST-NO, 80 AMP, 1200VDC, 12VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Gigavac P195BDA, Contactor SPST-NO, 80 AMP, 1200VDC, 12VDC Coil Contactor Features Perfect for Photovoltaic/Battery Systems Hermetically Sealed (Patented) rated to 175 Deg C High Efficiency Dual DC Coils - 12,24,48VDC options Ideal for battery powered systems or where low power is needed Built in Coils suppression for all DC Coils Small and lightweight Flexible package for installation Chassi level power terminals Specification Gigavac Part Number P195BDA Main Contact Type SPST-NO Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 80 Amp Mechanical Life @ 0 Amp 100,000 Operations Dielectric at Sea Level 4.3kV rms Control Input Terminals M3 Screw Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 1200VDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style M4 Screw Unit Weight 135g Factory Pack Qty 1 Datasheet Product Datasheet
$157.26
$185.57 inclGST -
D2450-B, Solid State Relay, NORMALLY CLOSED, Single Phase 3-32VDC Control, 50A, 24-280VAC Load
Crydom D2450-B, Solid State Relay, NORMALLY CLOSED, Single Phase 3-32VDC Control, 50A, 24-280VAC Load Features Ratings from 25A to 125 Amp @ 24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2450-B Switching Type Zero Crossing, NORMALLY CLOSED ROHS Yes (Details) Control Voltage 3-32VDC Load Current 50 Amp (rms) Surge Capability 597 Amp (peak) Special Feature Normally Closed Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$111.92
$132.07 inclGST -
FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output
LEM FRS 1000-SUI, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coresless Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1000-SUI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$429.00
$506.22 inclGST -
HS211 + HA4850E, Panel or slide on Din Rail Solid State Relay 24VAC Control Input, 90-530VAC Output, 25 Amps
Crydom HS211 + HA4850E, Panel or slide on Din Rail Solid State Relay 24VAC Control Input, 90-530VAC Output, 25 Amps Features Ratings from 25A to 125 Amp @48-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + HA4850E Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 18-36VAC Load Current 25 Amp (rms) @ 40 Deg C Surge Capability 597 Amp (peak) Special Feature LED Status Indicator Mounting Style Din Rail or Panel Mount Load Voltage Range 48-530VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 Series 1 HD Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$180.90
$213.46 inclGST -
H37 Heatsink, Full Lengths or cut to order Milled or Raw Finish
H37 (Semikron P35) Heatsink Profile 40mm x 250mm, Various Lengths cut to order, Milled or Raw Finish Note: for Milled finish. we can mill 150mm each pass leaving a line in the centre. Note: for any lengths not showing in stock, and we have longer lengths in stock, the profile is available in 2-3 days to cut and mill. Datasheet Product Datasheet
$53.50 - $450.00