Iskra Doo RI61J C 50-4.5kA, 1 Pole DC Miniature Circuit Breaker Disconnect Switch C Curve 50 Amp, 220VDC, 4.5kA
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
4.5kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Iskra Doo Part Number
RI61J C50
Functions
1 Pole MCB - C Curve
Nominal Voltage
220VDC
Nominal Current Range
50 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 55 Deg C
Rated Operations
10,000 Ops
Surge Current
220V
Short Circuit Current
4.5kA
Approvals
VDE, GOST-R
Standards
IEC/EN 60898,60947-1/2, IP20 (IP40 Installed) IEC 61008 ;
Weight
130g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Trent NBR-FR22GR69V125T + RT18-125L Series 125 Amp 690V Semiconductor I²t gR Fuse & DIn Rail Fuse Holder Cartridge Style
Features
Cylindrical Standard Fuses Sizes
Wide Range of I²t
Ratings up to 125 Amp
Quick Release with RT18-125L fuse holder
DIN Rail Mount with RT18-125L fuse holder
Compatible with all 58 x 21mm fuse holders
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Applications
Solid State Relay Switchboards
Bridge rectifier Fusing
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FR22GR69V125T + RT18-125L
Fuse Type
I²t gR Class
Nominal Voltage
690VAC @ 50Hz
I²t Rating (Pre-Arcing)
8100 A²/s
Nominal Current (RMS + DC)
125 Amp
Tested Breaking Capacity
200kA @ 690VAC
Dimensions
123 x 76 x 37.5mm
Fuse Holder
RT18-125L
Mounting Style
Din Rail Mount
Operating Temperature Range
-40°C / 125°C
Watt Loss
22.8W
DC Breaking Capacity
50kA
Unit Weight
60g
Factory Pack Qty
10
Datasheet
RT18-125L
Datasheet
RCS-4800-XXXX Three-Phase Flexible Current Sensor System (Rogowski Coils):
Contact Us for Possible Replacement for specific Ratings
The RCS-4800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-4800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-4800-XXXX
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500-5000 Amp RMS (please specify with order)
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
RCS-1205-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 4 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System:
The RCS-1205 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-1205 comes with 5 Amp integrator..
Included is an 12 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-1205-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Outptu Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
2000g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
RCS-2405-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 8 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-2405 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-2405 comes with 5 Amp integrator..
Included is an 24 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-2405-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
8 Inch
Coil Circumference
24 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
2500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
RCS-3605-VAR, 5 Amp Output, Class 1 Three Phase 500/1000/2500/5000\10000\25000\50000 Amp AC Measurement 12 Inch Diameter Rogowski Coils with Integrator Flexible Current Sensor System (Rogowski Coils):
The RCS-3605 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 5 Amp.
A 24VDC Power Supply is included to operate these coils. The RCS-3605 comes with 5 Amp integrator..
Included is an 36 inch circumference rope CT with Integrator, and power supply.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-3605-VAR
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
500/1000/2500/5000\10000\25000\50000 Amp RMS Selectable
Measurement Range
10% - 130% if Ipn
Output Range
0-5 Amp
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
24VDC
Accuracy
1% from 25 to 5000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
3500g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS-VAR Series Installation Guide
Manual Battery Switch, DPST 2 x 500 Amp 32VDC, Flange Mount 120mm Wide, M10 Terminations, IP67/IEC529
DC battery switches are designed to be placed in between the battery and load. Suitable for any low voltage DC application which requires up to 2kA overload for 1.5 minutes.
Features :
2 Pole Disconnect
Suitable for DC Isolation
Standards :
IEC 60364-7-712
IP65 (Front) IP20 (Terminals)
Specification
Gigavac Part Number
BD9513
Functions
2 Pole DC DPST Disconnect Switch, ON/OFF Red Lever
Nominal Voltage
32VDC
Nominal Current
2 x 500 Amp DC
Rated Impulse Voltage
1.05kV (1 min)
Rated Insulation Voltage
32VDC
Short Circuit Current
2kA (1.5 min), 2.5kA (10s)
Mounting
Outdoor/Indoor Panel Mount
Panel Size
N/A
Standards
IP67/IEC529
Termination
M10
Weight
700g
Enclosure Material
Zytel
Factory Pack Qty
10
Datasheet
Product Datasheet
Schurter 0090.0012 ASO 10.3x38mm GpV Fast Blow Solar Fuse 12Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0012
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
642 kA²/s
Nominal Current (DC)
12 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.97W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fuse Holder
FSO Fuse Holders
Schurter 0090.0025 ASO 10.3x38mm GpV Fast Blow Solar Fuse 30Amp, 1000VDC, 20kA, IEC 61730-2
Features
Meets the new UL and IEC photovoltaic standards
UL Recognized for 1000 VDC
High breaking capacity of 20 kA @ 1000 VDC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
0090.0030
Fuse Type
I²t GpV Class Fast Blow
Nominal Voltage
1000VDC
I²t Rating (Pre-Arcing)
2679 kA²/s
Nominal Current (DC)
30 Amp
Tested Breaking Capacity
20kA @1000VDC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
3.92W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders
Schurter 8020.2053 AEO 10.3x38mm Fast Blow Automotive Fuse 30Amp, 1000VDC, 20kA, IEC 61730-2
Features
UL Recognized for 1000 VDC, and 275VAC
High breaking capacity of 20 kA @ 1000 VDC, 10kA @ 175VAC
Low min. interrupting rating of 1.35 x In
Meets the requirements of IEC 61730-2 for PV module safety
Applications
All photovoltaic applications
Inverters
Battery charge controllers
In-line protection
String fuses
Specification
Schurter Part Number
8020.2053
Fuse Type
I²t GpV Class Automotive Fuse
Nominal Voltage
1000VDC, 275VAC
I²t Rating (Pre-Arcing)
3150 A²/s
Nominal Current (DC)
25 Amp
Tested Breaking Capacity
20kA @1000VDC 10kA @ 275VAC
Dimensions
10.3 x 38mm
Fuse Holder
FSO Fuse Holders
Mounting Style
Requires fuse holder
Operating Temperature Range
-40°C / 125°C
Watt Loss
1.8W
DC Breaking Capacity
20kA
Unit Weight
8g
Factory Pack Qty
10
Datasheet
Product Datasheet
Compatible Fuse Holder
FSO Fuse Holders