Fastron Electronics FESCT-19-150-100mA, 150Amp/100mA measurement Split Core CT's, Class 1, w/1M Flying Leads, HY2.0 Connection, 19x19mm Aperture, 100mV Class 1 Series Current Transformer
Features
Quick Release Split Core System
1m Flying Leads
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.60/3kV
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
FESSCT-19-150-100mA
Technology
Split Core AC Current Transformer
Ratio
150/100mA
Aperture Size
19 x 19mm
VA Rating
N/A
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 55°C
Continuous Current (max)
150Amp x 1.2
Termination Style
1M Twisted Pair 0.34mm^2
Unit Weight
350g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron FTCS Series Type S Ceramic Thermocouple, Various Lengths Recrystallised Allumina 1400ºC 21x50mm Support Tube, KNE Alminium Die Cast Terminal Head, KNE(wire entry:M20x1.5, probe entry: G1/2'')
Class A Accuracy
50mm Support Tube
0.35mm Internal wire diameter
Low Long Term Drift
Rated for -50 to 1400 Deg C Max
Terminal Head Connection
300(50)mmor 450(50)mm Long x 16(21)mm Sheath
Ceramic Sheath with Recrystallaised Allumina
Recommended to use Flange Fitting for mounting
Specification
Fastron Part Number
FTCS Series
Sensor Type
Type S Thermocouple
No of Wires
2
Probe Length
300mm or 450mm (Includes 50mm Support Tube)
Sheath Thickness
16(21)mm
Sheath Material
Ceramic & Recrystallasied Allumina
Accuracy
Class A
Approvals
CE, ANSI, ROHS
Cable Length
Terminal Head
Terminal Head Type
Die Cast Alloy Terminal Head, , KNE(wire entry:M20x1.5, probe entry: G1/2'')
Temperature Range
-50 to 1400 Deg C
Special Feature
Ceramic
Mounting Style
Flange Fitting Recommended
Weight
850g
Factory Pack Qty
1
Datasheet
Datasheet
Flange Datasheet
Fastron FTCK-5-PLAS-5000-B, Type K Class B, Thermocouple, Plastic Industry Style x 4.5mm Probe w/ 2000mm Screened Teflon/Braided SS cable, -20 to 400 Deg C
Quick Release Fitting for Plastic Industry
Class B Accuracy
Teflon SS Braided Cable
Low Long Term Drift
Rated for -20 to 850 Deg C Max
Spring Cable Connection
20 x 4.5mm
MIMS
Specification
Fastron Part Number
FTCK-5-PLAS-5000-B
Sensor Type
Type K Thermocouple
No of Wires
2
Probe Length
20mm
Sheath Thickness
4.5mm
Sheath Material
SS304 Stainless Steel
Accuracy
Class B
Approvals
N/A
Cable length
5 Meters
Cable Type
Teflon/Braided Stainless Steel with Spring Bayonet Cap
Temperature Range
-20 to 350 Deg C
Special Feature
Quick Release Fitting, Strain Relief Spring Cable
Mounting Style
Quick Release Fitting
Weight
380g
Factory Pack Qty
1
Datasheet
Datasheet
Fastron FTCJ-5-PLAS-3000-B 4.5mm Type J Metal Sheath Thermocouple with Spring Bayonet Cap
Quick Release Bayonet Fitting for Plastic Industry
Class B Accuracy
Teflon SS Braided Cable
Low Long Term Drift
Rated for -20 to 850 Deg C Max
Spring Cable Connection
20 x 4.5mm
MIMS
Specification
Fastron Part Number
FTCJ-5-PLAS-3000-B
Sensor Type
Type J Thermocouple
No of Wires
2
Probe Length
20mm
Sheath Thickness
4.5mm
Sheath Material
SS304 Stainless Steel
Accuracy
Class B
Approvals
N/A
Cable length
3 Meters
Cable Type
Teflon/Braided Stainless Steel with Spring Bayonet Cap
Temperature Range
-20 to 350 Deg C
Special Feature
Quick Release Fitting, Strain Relief Spring Cable
Mounting Style
Quick Release Fitting
Weight
300g
Factory Pack Qty
1
Datasheet
Datasheet
Type R Temperature Sensor Socket Round, Green, Wire Fitting for use with Thermocouple 220 Deg C Max
Rated for 220 Deg C
For Typoe R Thermocouple
Suitable for internal oven use
Datasheet
Thermocouple Connectors Brochure
F923 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm
Features
Isolated measurement of DC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F923-X-XX-DC-XX
Functions
Single Phase DC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm
Features
Isolated measurement of DC currents using internal Hall effect transducer.
Incorporates an integrated input level display and power supply.
Wide measurement range available
Choice of standard outputs
Wide range isolated DC input supply
DIN Rail mounting
Signal Conditioned DC measurement output
On board bar graph display
User adjustable zero offset and span controls
Zero insertion loss in current measurement path
Earth leakage via differential Ipn for nominal Input ‘01’
Applications
Process control
Transportation
Petrochemical
Industrial
Earth Leakage
Energy Monitoring/Measurement
Automation
Delivery
Delivery in 3-5 days for small qty. Otherwise 4-6 weeks
Specification
Oztherm Part Number
F923-X-XX-DC-XX
Functions
Single Phase AC Current Transducer
Supply Voltage
9-36VDC
Nominal Measurement Range
0-8 Amp (Sensor dependant)
Maximum Measurement Range
8 Amp
Alarm
C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC
Response Time
250mS
Accuracy @ 25 Deg C
Class 1
Bandwidth
DC - 1kHz
linearity
< 0.15%
Isolation
2.5kV
Comms
N/A
Weight
250g
Enclosure Size
79 x 60 x 85mm
Factory Pack Qty
1
EU Directives
N/A
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
Polyamide non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP40
Shock Withstand
300g 8ms Pulse . 6 Shocks in each of 3 axes
Vibration Withstand
0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Temperature Sensor Plug Round, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Thermocouple
Suitable for internal oven use
Datasheet
Thermocouple Connectors Brochure
Temperature Sensor Plug Flat, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Thermocouple
Suitable for internal oven use
Datasheet
Thermocouple Connectors Brochure
TType N Temperature Sensor Plug Round, Orange, Wire Fitting for use with Thermocouple 220 Deg C Max
Rated for 220 Deg C
For Type N Thermocouple
Suitable for internal oven use
Datasheet
Thermocouple Connectors Brochure
Temperature Sensor Socket Flat, Wire Fitting for use with Thermocouple
Rated for 220 Deg C
For Thermocouple
Suitable for internal oven use
Datasheet
Thermocouple Connectors Brochure