DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVL 125 Digital Voltage Transducer, Vpn = 125V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation Features Bandwidth DC to 14kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 125 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 125V Measurement Range +/- 187.5V Output 50 mA @Vpn Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
H-100-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-100 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-100-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-100 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-100 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-100-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-100 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
-
H-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-500-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-500 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-500 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-500-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-500 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
FTA-005-420B-24, DC Current Transducer, +/-5 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-005-420B-24, DC Current Transducer, +/-5 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-5 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-5A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-005-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-5 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FWBV414H29-50AC-010, AC Voltage Transducer, 0-50V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request)
Fastron Electronics FWBV414H29-50AC-010, AC Voltage Transducer, 0-50V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request) Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number FWBV414H29-50AC-420 Control Output 4-20mA Average RMS Input 0-50VAC, 50/60Hz (25Hz - 1kHz Available on Request) Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$269.00
$317.42 inclGST -
FP010080P/1A, 100/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP010080P/1A, 100/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP010080P/1A Technology Split Core AC Clip On Current Transformer Ratio 100/1 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
H-30-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-30 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply
Free Aus Post Shipping for $300 SpendH-30-MOD-24, Split Core Bipolar Hall Effect DC Current Transducer, +/-30 Amp DC, RS485 Modbus RTU output, 31mm aperture, 24VDC supply Compact and versatile Split Core Bipolar DC current sensor, +/-30 Amp DC, Modbus RS485output Features Modbus RTU (RS485)output ⌀31mm Aperture Split Core DC Measurement Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number H-30-MOD-24 Technology DC Hall Effect Current Transducer with Processoutput ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-30 Amp Response Time < 200mS Output RS485 Modbus RTU Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 200g Factory Pack Qty 6 Datasheet Product Datasheet
-
FP030080P/1A, 300/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm
FP030080P/1A, 300/1 Amp Split Core CT, Class 1, 1.5VA Clip On AC Current Transformer, 50 x 80mm Aperture, Dimension 145 x 159 x 37mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number FP030080P/1A Technology Split Core AC Clip On Current Transformer Ratio 300/1 Aperture Size 50 x 80mm VA Rating 1.5VA Accuracy Class Class 1 Output 1 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 300Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$112.00
$132.16 inclGST -
FTCK-PIPE-3000, Type K Clamp Style Thermocouple for Pipes, Various Clamp Sizes, 3000mm 2 Wire Braided SS/Fibreglass/Teflon Wire, CE, ANSI, ROHS Approved
Free Aus Post Shipping for $300 SpendFastron FTCK-PIPE-3000, Type K Clamp Style Thermocouple for Pipes, Various Clamp Sizes, 3000mm 2 Wire Braided SS/Fibreglass/Teflon Wire, CE, ANSI, ROHS Approved Features Class A Accuracy Pipe Clamp Style Sensor Low Long Term Drift Rated for -20 to 370 Deg C Max 3000mm Tail Length Available in custom lengths Fibreglass Sheath Specification Fastron Part Number FTCK-PIPE-3000 Sensor Type Type K Thermocouple Ungrounded No of Wires 2 TailLength 3000mm or custom Clamp Size 7/32 -> 5/8", 3/8 -> 1/2", 3/8 -> 5/8", 1/2 -> 5/8", 5/8 -> 3/4", 3/4 -> 1", 1 1/4 -> 1 1/2", 1 1/4 -> 1 3/4", 1 1/2 -> 2", 1 3/4 -> 2 1/4", 2 1/16 -> 3", 2 5/16 -> 3 1/4", 3 -> 3 1/4", 3 - 1/4", 3 -> 3 1/2", 4 -> 4 1/2", 4 1/6 -> 5", 4 5/8 -> 5 1/2", 5 1/8 -> 6", 5 7/8 -> 6 3/4" Sheath Material Fibreglass Accuracy Class A Cable Type Briaded SS/Fibreglass/Teflon Temperature Range -20 to 370 Deg C Special Feature Pipe Clamp Mounting Style Clamp Weight 300-500g Factory Pack Qty 1 Datasheet Product Datasheet
-
Rish Xmer Splt Core 195/80 2500/5 Split Core CT Class 1 30VA, 85 x 172mm Aperture
Rish Xmer Splt Core Split Core 2500/5 Amp 195/80 Class 1, 30VA Series Current Transformer, 85 x 172mm Aperture Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number Rish Xmer Split Core 2500/5 195/80 Technology Split Core AC Current Transformer Ratio 2500/5 Aperture Size 172 x 85mm VA Rating 30VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 40°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Unit Weight 2kg Factory Pack Qty 9 Datasheet Product Datasheet
$383.00
$451.94 inclGST -
DC-0-300-420-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-300-420-1.0, Hall Effect DC Current Transducer, 0-300 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-300 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-300-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-300 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST