Fastron Electronics SCT-Y24-10A/100mA, 10A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter
Features
Quick Release Split Core System
Cable Mount
100mA Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Specification
Fastron Part Number
SCT-Y24-10A/100mA
Technology
Split Core AC Current Transformer
Ratio
10/100mA
Aperture Size
ø 24 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 10Hz, 1 min)
Bandwidth
10-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
10Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Crydom A2450G, Solid State Relay, Single Phase 90-280VAC Control, 50A, 24-280VAC Load, w/status LED
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
A2450G
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
90 - 280VAC
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crouzet BM2R08MV1 Syr-Line Single Pole Multifunction Timer With DPDT CO Contacts
BM1R Timers Syrline 17.5 mm - 2 Relays 8A :
Multi-function (12 functions)
Multi-range (0.5s - 10days)
Multi-voltage 12 →240 V AC/DC
LED status indicator
Possibility of external load connection in parallel to the control input
3-wire PNP sensor compatible
Multifunction Timers Includes The Following :
Function A Delay on energisation 1 relay
Function Ac Timing after closing and opening of control contact 1 relay
Function At Timing on energisation with memory 1 relay
Function B Timing on impulse one shot 1 relay
Function C Timing after impulse 1 relay
Function D Flip-flop Pause start 1 relay
Function Di Flip-flop Pulse start 1 relay
Function H Timing on energisation 1 relay
Function Ht Delay on energisation with memory 1 relay
Function N Watchdog
Function Tl Timed impulse relay
Function TL Impulse relay
Specification
Crouzet Part Number
BM2R08MV1 (Syr-Line Timer Double Pole Multifunction, 12 - 240VAC/DC, 17.5 mm)
Function
Multifunction Timer A - Ac - At - B - C - D - Di - H - Ht -N - TL - Tt
Nominal Voltage
12 → 240 V AC/DC
Digital Output
2 x C/O (DPDT) (Changeover -Single Pole Double Throw-), 250VAC/DC @ 8 Amp R1 = Follows Timing, R2 = Instantaneous
Min Breaking Current
10mA/12VDC
Timing Ranges
Selectable 0.5→10s, 0.05→1min, 0.5→10min, 0.05→1h, 0.5→10h, 0.05→1day, 0.5→10days
Minimum Pulse Duration
30ms/100ms with load
Repeatability
0.5%
Reset Time
120ms
Isolation
4kV
Repetition Accuracy
0.5%
Threshold Adjustment Range
10 → 100 % of the range
Termination Style
Screw
Weight
80g
Certification
CE, cULus,CCC, ROHS, Reach, WEEE
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
TCD-S-3-K HEATING Temp Controller, 48x48mm 230VAC, C/O Relay output, Type K Input. Encoder Control,amp; Digital Display, 0-999 Deg C
Pushbutton Encoder Setpoint
3-digit display (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated ON/OFF Relay, output, Optional cooling or time proprtional versions output available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TCD-S-3-K
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Type K Thermocouple
Control Mode
Time Proportional Control
Control Range
0- 999 Deg C
Mounting Style
48x48mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Sampling Time
50ms
Weight
270g
Factory Pack Qty
1
Datasheet
TCD/TCR/FC5 Datasheet
TCD/TCR User Manual
Crydom D53TP50D, Solid State Relay, 3 Phase 4-32VDC Control, 50A, 48-530VAC Load
Features
Ratings from 25A to 50 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
50 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom LND2425, Solid State Relay, Single Phase 3-32VDC Control, 75A, 24-280VAC Load, Low Noise, Low EMC/RFI
Features
• Ratings from 25A to 75 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
LND2425
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
25 Amp (rms)
Surge Capability
297 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DC60S3-B, NORMALLY CLOSED Solid State Relay, DC 3-32VDC control, 3A, 60VDC Load
Features
Ratings from 3A to 40 Amp @ 3-60VDC
Transistor output
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
DC60S3-B
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
3 Amp DC
Surge Capability (10ms)
6 Amp DC
Special Feature
Normally Closed
Mounting Style
Panel Mount
Load Voltage Range
3 - 60VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See D1D40K with raised terminals (Gen 3) for alternative or DC60S7, D1D20, D1D40, D1D80 for higher current alternatives
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom ASO241R, Mini-SIP Solid State Relay, 4-10VDC Control, 1.5Amp 24-280VAC Load
Features
Ratings up to 1.5 Amp @ 280VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ASO241R
Switching Type
Random Crossing
ROHS
Yes (Details)
Control Voltage
4-10VDC
Load Current
1.5 Amp (rms)
Surge Capability
40 Amp (peak)
Special Feature
None
Mounting Style
PCB Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
PCB
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
FRS3-C40-1000R, 1000VDC Surge Protection Device for Photovoltaic Systems, Type 1 (Class I) + Type 2 (Class II) 40kA WITH REMOTE C/O CONTACTS
Specifications
Trent part number
FRS3-C40-1000R
Nominal Voltage
1000VDC
No of Poles
3
Category IEC / EN / VDE
Type 1 (Class I) + Type 2 (Class II)
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES NO/NC/COM
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC614643-31:2018 (TUV, CE Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Techsem MT800-24-432F2, Single Thyristor Module, 80 Amp, 2200V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
70mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MT800-24-432F2
Vrrm
1800V
Diode Configuration
Single Thyristor Module
IF(av) @ 85 Deg C
800 Amp
Package Size
W:70mm L:146mm D:90mm
Itsm
22 kA
VF(to)
0.85V
Tj(max)
125°C
rF
0.17mΩ
I(gt) @ 25 Deg C
200mA
Terminals
M12 Screw
Hole Centres
80mm x 58mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.042°C/W
R th(c-h)
0.02°C/W
Weight
2.8kg
Mounting Torque
6 Nm (13 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
Techsem
Datasheet
Product Datasheet
Alternatives
tz860n16kof
Contact Us for Possible Replacement
R5001415XXZT M8, Rotating Diode, M8 THD Stud, Anode Stud, with 114mm Tail
User for Rotating Generator or Motor Applicatons
150 Amp Rating
Datasheet
Datasheet