Search results for "텔레:bpmc55*^위고비부작용비아그라"
-
FDH8048ZD3, Solid State Relay, 480VAC, 80 Amp, 3-32VDC Control, Zero Crossing, Panel Mount, w/plastic Cover
Fastron FDH8048ZD3, Solid State Relay, 480VAC, 80 Amp, 90-280VAC Control, Zero Crossing, Panel Mount, w/plastic Cover Ratings from 25A to 125 Amp @ 48-480VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs CE Compliant to EN60950-1 AC & DC control types Direct bond copper substrate Direct power lead frame Specification Fastron Part Number FDH8048ZD3 Switching Type Zero Crossing CE Yes Control Voltage 3-32VDC Load Current 80Amp (rms) Surge Capability 910 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 90-480VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 250g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent Parts HD4875
$66.00
$77.88 inclGST -
FST-1HV12R10-3A25kV, Diode Array for Electrostatic Precipitator, 24kV, 3 Amp, L:140 x W: 97.5 with 6.35 hole centres
Free Aus Post Shipping for $300 SpendDiode Array for Electrostatic Precipitator, 24kV, 3 Amp, L:140 x W: 97.5 with 6.35 hole centres
Free Aus Post Shipping for $300 Spend$1,350.00
$1,593.00 inclGST -
GX11CAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Gigavac GX11CAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 24VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX11CAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 24VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet Equivalent Parts GX11CAB
$245.00
$289.10 inclGST -
KC12-11-230-50 Capacitor Duty Contactor 240/480/600VAC @ 6, 12, 15 kVar, 200,000 Operations, AC-6B
Iskra Doo KC12-11-230-50 Capacitor Duty Contactor 240/480/600VAC @ 6, 12, 15 kVar, 200,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KC12-11-230-50 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 6kVar/Amp @230VAC, 12kVar/Amp@480VAC, 15kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog
$49.14
$57.99 inclGST -
KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B
Iskra Doo KC25-11-230-50, Capacitor Duty Contactor 240/480/600VAC @ 12.5, 25, 33.3 kVar, 100,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KC25-11-230-50 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 12.5kVar/Amp @230VAC, 25kVar/Amp@480VAC, 33.33kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 1 x NC Trip Delay Time 2-10ms Electrical Life 100,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 1,000,000 Ops Control Voltage 230VAC Power Dissipation 2W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog
$95.76
$113.00 inclGST -
KC33-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 16.5, 33.3, 40 kVar, 100,000 Operations, AC-6B
Iskra Doo KC33-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 16.5, 33.3, 40 kVar, 100,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KC33-12-230-50 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 16.5kVar/Amp @230VAC, 33.3kVar/Amp@480VAC, 40kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 2 x NC Trip Delay Time 2-10ms Electrical Life 100,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 1,000,000 Ops Control Voltage 230VAC Power Dissipation 4.2W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog
$132.30
$156.11 inclGST -
KNK3053 10KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 165mm Dry Type, 3 x 38.5uF, Includes Discharge Resistor
Iskra Doo KNK3053 10 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 165mm Dry Type, 3 x 38.5uF Characteristics and utility 10kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 10 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 90 x 165mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 10 Kvar Capacitance 3 x 38.5uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 7.2 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 1.1kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
$139.00
$164.02 inclGST -
KNK3053 15KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 57.7uF, Includes Discharge Resistor
Iskra Systemi 15 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 57.7uF Characteristics and utility 15kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 15 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 90 x 210mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 15 Kvar Capacitance 3 x 57.7uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 16.5 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 1.5kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
$145.00
$171.10 inclGST -
KNK3053 30KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type, 3 x 115.5uF, Includes Discharge Resistor
Iskra Doo KNK3053 30 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 245mm Dry Type, 3 x 115.5uF Characteristics and utility 30kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 30 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 116 x 245mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 30 Kvar Capacitance 3 x 115.5uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 33 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 3kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
$249.00
$293.82 inclGST -
KNK3053 40 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 285mm Dry Type, 3 x 154uF, Includes Discharge Resistor
Iskra Doo KNK3053 40 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 116 x 285mm Dry Type, 3 x 154uF Characteristics and utility 40kVar @ 525V @ 50 Hz / 25kVar @ 400VAC Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 40 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 116 x 285mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 40 Kvar Capacitance 3 x 154uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 44 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 3.6kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
$299.00
$352.82 inclGST -
KNK3053 5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type, 3 x 19.3uF, Includes Discharge Resistor
Iskra Systemi KNK3053 5 KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, Dry Type, 3 x 19.3uF Characteristics and utility 5kVar @ 525V @ 50 Hz 10.0kvar 10kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 5 KVAR 525V 50HZ Technology Dry Type, Low Loss, Self Healing Dimensions 75 x 165mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 5 Kvar Capacitance 3 x 19.3uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 5.5 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 0.9kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
$85.60
$101.01 inclGST -
KNK3053 50KVAR 525V 50HZ H, Heavy Duty, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF, Includes Discharge Resistor
Iskra Doo KNK3053 50 KVAR 525V 50HZ Heavy Duty, Power Factor Correction Capacitor, 3 Phase, Dry Type 136x285mm, 3 x 192.48uF Characteristics and utility 50kVar @ 525V @ 50 Hz 50kvar Heavy Duty 150,000Hours Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - Feed through terminals Indoor mounting Triple safety Overpressure disconnection system Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KNK3053 50 KVAR 525V 50HZ H Technology Dry Type, Low Loss, Self Healing Dimensions 136 x 285mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 50 Kvar Capacitance 3 x 192.48uF Tolerance On Capacitance -5% + 10% (others on request) Current (In) 36 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Double sided Filter Type Terminal Unit Weight 4.2kg Factory Pack Quantity 25 Datasheet Iskra PCF Catalogue Capacitor Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables Hot Spot Testing 25kvar Specification Sheet 40kvar Specification Sheet
$349.00
$411.82 inclGST