RODN604025, Steel Enclosure, 600mmH x400mmW x 250mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel
Features
Injected Polyurethane Sealing gasket
3 x M20 cable glands
4pcs Wall Mounts and dynabolts included
Lockable Door via Key
RAL7035 GREY AS3000/AS3100 Compliant
IP66
Specification
Fastron Part Number
RODN604025
Function
Steel Water Proof Enclosure
Configuration
Enclosure with Hinged Door, Key Lock, 4 Mounting Clips, DYnabolts, and Cable Glands
Termination Style
Screw
Dimensions
H:600 x W:400 x D:250mm
Weight
15.6kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
1.5mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP66
Operating Temperature
-20...55 °C
Datasheet
Datasheet
Crydom HD4875G, Solid State Relay, Single Phase 3-32VDC Control, 75A, 48-530VAC Load, w/status LED
Features
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HD4875G
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
75 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See HD4875 for stocked equivalent (no LED).
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Protec T1-1500PV-3+0-S(-R), 1500VDC Surge Protection Device for Photovoltaic Systems, Type 1, Type 2/Open Type 1 SPD Listed, with Remote Contact
Specifications
Raycap part number
T1-1500PV-3+0-S(-R)
Nominal Voltage
1500VDC
No of Poles
3
Category IEC / EN / VDE
Type 1, Type 2/Open Type 1 SPD Listed
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES
Protective element
MOV + GDT
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 12.5kA (10/350uS), 60kA(8/20uS)
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
RTR Energia EA0525500500000 Power Factor Correction Capacitor, Single Phase, Dry Type 5.0 KVAR, 57.74uF, 525V, 50HZ, 60 x 200mm
Characteristics and utility
5.0 kVar @ 525V @ 50 Hz , 57.74uF10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525500500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 200mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
5.0 Kvar
Capacitance
57.74uF
Tolerance On Capacitance
-5% + 10%
Current (In)
9.52 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
ProTec T1-750PV-S-P, ProTec Cartridge Replacement. MIDDLE PLUG In for T1-1500PV-3+0-S(-R)
Specifications
Raycap part number
ProTec T1-750PV-S-M-P
Nominal Voltage
750VDC
No of Poles
3
Category IEC / EN / VDE
Type 1, Type 2/Open Type 1 SPD Listed
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
YES
Protective element
MOV + GDT
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 12.5kA (10/350uS), 60kA(8/20uS)
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
RTR Energia EA0525167500000 Power Factor Correction Capacitor, Single Phase, Dry Type 1.67 KVAR, 19.29uF, 525V, 50HZ, 60 x 150mm
Characteristics and utility
1.67 kVar @ 525V @ 50 Hz , 19.29uF10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525167500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
1.67 Kvar
Capacitance
19.29uF
Tolerance On Capacitance
-5% + 10%
Current (In)
3.18 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Techsem MTC570-16-416F3, Dual Thyristor Module, 570 Amp, 1600V
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
60mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC570-16-416F3
Vrrm
1600V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
500 Amp
Package Size
W:60mm L:144mm D:52mm
Itsm
17 kA
VF(to)
0.9V
Tj(max)
125°C
rF
0.27mΩ
I(gt) @ 25 Deg C
250mA
Terminals
M10 Screw
Hole Centres
80mm x 48mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.065°C/W
R th(c-h)
0.02°C/W
Weight
1500g
Mounting Torque
6 Nm (12 Nm Terminals)
Factory Pack Qty
2
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See MCC552-16io1
See TT570N16KOF
RTR Energia EA0525083500000 Power Factor Correction Capacitor, Single Phase, Dry Type 0.835 KVAR, 9.59uF, 525V, 50HZ, 60 x 150mm
Characteristics and utility
0.835 kVar @ 525V @ 50 Hz, 9.59uF 10.0kvar 10kvar
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA0525083500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
60 x 150mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
0.835 Kvar
Capacitance
9.59uF
Tolerance On Capacitance
-5% + 10%
Current (In)
1.58 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
LEM DVL 750 Digital Voltage Transducer, Vpn = 750V, 50mA output, +/-15...24VDC powered, 8.5kV Isolation
Features
Bandwidth DC to 14kHz
Digital Transducer (ASIC based)
Closed loop transducer using Hall effect
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVL 750
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24 VDC Bipolar, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 750V
Measurement Range
+/- 1125V
Output
50 mA @Vpn
Isolation
8.5 kV
Bandwidth
DC-14 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
270g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition