LEM DHAB S/118 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-30A, and +/-350A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/118
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-30 Amp
Load Current Channel 2 (RMS)
+/-350 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.45%(20A),0.7%(30A)
CH2 Accuracy @ 25 Deg C
1%(0A),3.5%(175A),5%(350A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron Electronics GT-DVO(0-100V)D-1, DC Voltage Transducer, 0-100VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DVO(0-100V)D-1
Control Output
4-20mA
Input
0 - 100VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AM5H-A-DV5-D-NAN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 20-60VDC supply, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-DV5-D-NAN
Conditioner Output
4-20mA
Input
0 - 36VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
20-60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
5 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
MS Power MSD85N16MB Series Stud Mount Rectifier Diode
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD85N16MB
Vrrm
1600V
Diode Configuration
Cathode Stud
IF(av) @ 100 Deg C
95 Amp
IF(av) @ 125 Deg C
70 Amp
Itsm
1.15 kA
VF(to)
0.85V
Tj(max)
180°C
rF
3mΩ
Termination Style (Tail)
Solder Tab
Termination Style (Stud)
3/8" -24UNF2A
Tail Length to Stud
158mm
R th(j-c)
0.55°C/W
R th(c-h)
0.20°C/W
Weight
40g
Mounting Torque
4 Nm
Factory Pack Qty
10
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
LEM PCM 10-P/SP1 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output
Features
Closed loop sensor using Hall Effect
Panel mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
2M flying leads
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
PCM 10-P/SP1
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø15.6mm
Load Current (RMS + DC)
10 Amp
Measuring Range
+/- 20 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-1000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C (55°C Continuous)
Accuracy
0.5%
Termination Style
Switchcraft EN3L4M connector with 2M Flying Leads
Unit Weight
120g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ
LEM HOYL 800-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 800-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
800 Amp
Measurement Range
+/-2000 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYS 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 21.5 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYS 200-S-0100
Technology
Open Loop Hall Effect
Aperture
21.5 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
5.4 kV
Bandwidth
DC-180 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
101g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Crydom HD6050, Solid State Relay, Single Phase 3-32VDC Control, 50A, 48-660VAC Load
Features
Ratings from 25A to 125 Amp @ 24-600 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HD6050
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
3-32VDC
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
48-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
CY9008
CWD4890H
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
MS Power MSD Series Stud Mount Rectifier Diode
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD321R16MB
Vrrm
1600V
Diode Configuration
Anode Stud
IF(av) @ 100 Deg C
420 Amp
IF(av) @ 125 Deg C
320 Amp
Itsm
9 kA
VF(to)
0.80V
Tj(max)
180°C
rF
0.45mΩ
Termination Style (Tail)
11mm Round Lug
Termination Style (Stud)
M24 x 1.5P
Tail Length to Stud
230mm
R th(j-c)
0.15°C/W
R th(c-h)
0.015°C/W
Weight
350g
Mounting Torque
32 Nm
Factory Pack Qty
5
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
Crydom D53TP50D + KS300, SSR 3 Phase 4-32VDC Control, 50A, 48-530VAC Load, LED Status Indicator + Cover.
Features
Ratings from 25A to 50 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + KS300
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
50 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator + IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies