RCS-2400-3000 Three-Phase Flexible Current Sensor System(Rogowski Coils):
The RCS-2400 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-2400 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-2400-3000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
3000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 3000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
8 Inch
Coil Circumference
24 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
RCS-3600-1500 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-3600 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-3600 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-3600-1500
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1500 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
12 Inch
Coil Circumference
36 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Infineon DDB6U134N16RR 3 Phase Diode Rectifier Bridge, 134 Amp, 1600V, 42 x 94mm Package
Features
Package with DCB ceramic base plate
Isolation voltage 3600 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
Infineon Part Number
DDB6U134N16RR
AC Line voltage
533V
Device Configuration
Three Phase Rectifier Bridge
DC Output @ 100 Deg C
134 Amp
Package Size
W:45mm L:107.5mm D:20.5mm
Itsm
650 A
VF(to)
0.75V
Tj(max)
150°C
rF
Not Published
Terminals
Press Fit
Hole Centres
93mm (M5)
Gate Terminals
N/A
R th(j-c)
0.7°C/W
R th(c-h)
0.25°C/W
Weight
185g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
Infineon Headquarters
Germany
Datasheet
Product Datasheet
LEM DHAB S/118 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-30A, and +/-350A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/118
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-30 Amp
Load Current Channel 2 (RMS)
+/-350 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.45%(20A),0.7%(30A)
CH2 Accuracy @ 25 Deg C
1%(0A),3.5%(175A),5%(350A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron Electronics GT-DVO(0-100V)D-1, DC Voltage Transducer, 0-100VDC input, 22-60VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GTD-DVO(0-100V)D-1
Control Output
4-20mA
Input
0 - 100VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AM5H-A-DV5-D-NAN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 20-60VDC supply, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-DV5-D-NAN
Conditioner Output
4-20mA
Input
0 - 36VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
20-60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
5 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
MS Power MSD85N16MB Series Stud Mount Rectifier Diode
Features
Full blocking capability over wide temperature range
Hermetic metal case with glass insulator
Threaded stud
Applications
Power Supplies
Uncontrolled Rectifiers
Oil Cooled Circuits
Battery Chargers
Specification
MS Power Part Number
MSD85N16MB
Vrrm
1600V
Diode Configuration
Cathode Stud
IF(av) @ 100 Deg C
95 Amp
IF(av) @ 125 Deg C
70 Amp
Itsm
1.15 kA
VF(to)
0.85V
Tj(max)
180°C
rF
3mΩ
Termination Style (Tail)
Solder Tab
Termination Style (Stud)
3/8" -24UNF2A
Tail Length to Stud
158mm
R th(j-c)
0.55°C/W
R th(c-h)
0.20°C/W
Weight
40g
Mounting Torque
4 Nm
Factory Pack Qty
10
Country Of Origin
China
MS Power Headquarters
Germany
Datasheet
Product Datasheet
LEM PCM 10-P/SP1 Series Closed Loop Bipolar DC Hall Effect Sensor for Point System Monitoring, Bipolar 4-20mA Output
Features
Closed loop sensor using Hall Effect
Panel mounting
Split core design for easy installation
Insulated plastic case to UL 94-V0 Water resistant design rated to IP 67
Reverse polarity protected
2M flying leads
Advantages
Very good linearity
Excellent accuracy
Current overload capability
No insertion losses.
Non - contact measurement (does not need a safety case)
Applications
Railway equipment
Points condition monitoring
Signal light indication
Battery supplied applications Uninterruptable Power Supplies (UPS).
Specification
LEM Part Number
PCM 10-P/SP1
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
24V
Aperture
ø15.6mm
Load Current (RMS + DC)
10 Amp
Measuring Range
+/- 20 Amp
Overload Capacity (Ampere Turns)
30000 Amp
Output
4-20mA
Standards
EN 50121-59EMC),EN 50155(temperature and humidity),EN61010-1/2 (safety)
Bandwidth
DC-1000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-25°C / 70°C (55°C Continuous)
Accuracy
0.5%
Termination Style
Switchcraft EN3L4M connector with 2M Flying Leads
Unit Weight
120g
Factory Pack Qty
4
Datasheet
Product Datasheet
Application Notes
FAQ
LEM HOYL 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 40 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYL 200-S-0100
Technology
Open Loop Hall Effect
Aperture
40 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
8 kV
Bandwidth
DC-140 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
232g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYS 200-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 21.5 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYS 200-S-0100
Technology
Open Loop Hall Effect
Aperture
21.5 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
200 Amp
Measurement Range
+/-500 Amp
Output
2.5 Vref
Isolation
5.4 kV
Bandwidth
DC-180 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
101g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM HOYS 400-S-0100 Series Closed Loop AC/DC Hall Effect Sensor
Features
Open loop multi-range current transducer
Voltage output
Single supply +5 V
Overcurrent detect 2.93 × IPN (peak value)
Galvanic separation between primary and secondary circuit
Low power consumption
For busbar mounting
Aperture: 21.5 × 13 mm
Factory calibrated ? Mating JST connector:
housing PAP-05V-S
contact SPHD-00xT-P0.5.
Advantages
Low offset drift
Over-drivable Vref
Creepage / clearance > 10.5 mm
Fast response
Low profile 2 mm pitch connector for 22 to 28 AWG wire.
Applications
AC variable speed and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Combiner box
Solar inverter on DC side of the inverter (MPPT).
Standards
IEC 61800-2: 2015
IEC 61800-3: 2004
IEC 61800-5-1: 2007 ? IEC 62109-1: 2010 ? UL 508: 2013.
Application Domain
Industrial.
Specification
LEM Part Number
HOYS 400-S-0100
Technology
Open Loop Hall Effect
Aperture
21.5 x 13mm
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
400 Amp
Measurement Range
+/-1000 Amp
Output
2.5 Vref
Isolation
5.4 kV
Bandwidth
DC-180 kHz
Mounting Style
Busbar Mount
Operating Temperature Range
-40°C / 105°C
Accuracy
1%
Termination Style
JST B05B-PASK or equivalent
Unit Weight
101g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition