Search results for "텔레:bpmc55●◎마운자로운동위고비재고있는곳"
-
MSD403N18M M18, Rectifier Diode 400 Amp, 1800V, M18 x 1.5, Cathode stud
Free Aus Post Shipping for $300 SpendMSD403N18M M18, Rectifier Diode 400 Amp, 1800V, M18 x 1.5, Cathode stud Features Full blocking capability over wide temperature range Hermetic metal case with glass insulator Threaded stud Applications Power Supplies Uncontrolled Rectifiers Oil Cooled Circuits Battery Chargers Specification MS Power Part Number MSD403N18M M18 Vrrm 1800V Diode Configuration Cathode Stud IF(av) @ 100 Deg C 480 Amp IF(av) @ 120 Deg C 400 Amp Itsm 9.2 kA VF(to) 0.85V Tj(max) 180°C rF 0.51mΩ Termination Style (Tail) 10.6mm Round Lug Termination Style (Stud) M18 x 1.5 Tail Length to Stud 200mm R th(j-c) 0.13°C/W R th(c-h) 0.04°C/W Weight 250g Mounting Torque 26 Nm Factory Pack Qty 8 Country Of Origin China MS Power Headquarters Germany Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$119.00
$140.42 inclGST -
FP120125P/0.333V, 1200/0.333V Amp Split Core CT, Class 0.5, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm
FP120125P/0.333V, 1200/0.333V Amp Split Core CT, Class 0.5, 80 x 120mm Aperture, Dimensions 145 x 37 x 200mm Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Electronics Part Number FP120125P/0.333V Technology Split Core AC Clip On Current Transformer Ratio 1200/0.333V Aperture Size 85 x 120mm VA Rating 7.5VA Accuracy Class Class 0.5 Output 0.333V AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -10°C / 50°C Continuous Current (max) 1200Amp x 1.2 Termination Style Screw Approvals CE Unit Weight 1150g Factory Pack Qty 1 Datasheet Product Datasheet Installation Guide
$171.75
$202.67 inclGST -
F912 Series +/-15VDC Bipolar Power Supply
OEM +/-15VDC Bipolar Power Supply Open frame solution Din Rail Mount RMS Output with Galvanic Isolation Opitons Include 24AC/DC, 110VAC,240VAC,415VAC Output Current 160mA RMS Open frame solution Delivery in 3-5 days for small qty, Otherwise 3-4 weeks Operating Temperature Range: 0 to 50 Deg C Datasheet Product Datasheet
$200.00
$236.00 inclGST -
F920-A-XX-XX-XX Series AC/DC Current Transducer/Conditioner and Bipolar Power Supply, 9-36VDC Powered
F920-A-XX-XX-XX - Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor Features Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC Average RMS or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty, Otherwise 4-6 weeks Datasheet Datasheet
$409.00 - $439.00
-
F921-A-XX-XX-XX, Series AC/DC Signal Conditioner and Bipolar Power Supply with High and Low Alarm
F921-A-XX-XX-XX Signal Conditioner and +/-15VDC Bipolar Power Supply with Adjustable High and Low C/O Relay Alarm. +/- 4V Bipolar Input, For External LEM Hall Effect Sensor Features Isolated measurement of AC or DC currents using a Hall effect transducer with external aperture Incorporates an integrated input level display and power supply Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC Average RMS or DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty, Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-20000 Amp (Sensor dependant) Maximum Measurement Range 0-20000 Amp with External Sensor Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
F921 DC Series Current Transducer, 100mA to 400 Amp Range with Adjustable High and Low Solid State Alarm
F921 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of DC currents using a Hall effect transducer with external aperture. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F921-X-XX-DC-XX-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-400 Amp (Sensor dependant) Maximum Measurement Range 2500 Amp with External Sensor Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$595.00
$702.10 inclGST -
F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F923 DC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm
F923 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase DC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
$552.00 - $595.00
-
F312 Series Phase Angle SSR Control Module
Free Aus Post Shipping for $300 SpendFastron F312 Series Proportional Phase Control Solid State Relay Controller Proportional Phase Controller for SSR switching Ratings from 25A to 90 Amp @ 90-600 VAC Use any DC Control Solid State Relay Use any Solid State Contactor Instantaneous turn-on outputs Specification Fastron Part Number F312 Series Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA/POT Input (at time of order) Load Current N/A based on SSR Surge Capability N/A based on SSR Special Feature Proportional Controller for SSR Mounting Style DIN Rail Mount Load Voltage Range 90-415VAC Dielectric Strength 4kV Termination Style Screw Terminal Unit Weight 360g Factory Pack Qty 20 Datasheet Product Datasheet F312 User Manual Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Parts Contact Us for Possible Replacement
-
Phase Angle Controller, F311 Series Single Phase 240VAC, Cards Only
Oztherm F311 Series Single Phase SCR Phase Angle Controller, Card Only 100% Australian Made Single Phase, Phase Angle Controller or AC Soft Starter 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Phase angle switching Cards Only Applications Electrical Ovens, Kilns, or Furnaces AC Soft Starter Primary Control of Transformer Rectifers Controlled Power Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Sheet Metal Welding Available Options Voltage Regulation AC (A) Current Limit and Trip AC (C) Current Control/Constant Current AC (CC) Power Limit (PW) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overload Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F330 Series 3 Phase, Phase Angle Controller Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current 100 - 150 Amps Per Phase Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC, Current Control AC, Voltage Regulation AC, Power Limit, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 190-265VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 28kg Factory Pack Qty 1 Technical Docs F311 Brochure F311 Installation and Commissioning Manual Calibration Procedure Blog - New Calibration Procedure PDF Thyristor Wiring Diagrams - New Control Wiring Diagrams - New Customised models Customised models list Contact Us for Possible Replacement for customised features not listed
$815.00 - $1,344.00
-
DCR1260F42, Thyristor(SCR) PUK, 1260Amp, 4200V, 74/26
Dynex DCR1260F42 Thyristor(SCR) Capsule, 1260Amp, 4200V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Dynex Part Number DCR1260F42 Vrrm 4200V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 60 Deg C 1260 Amp Package Size ø74 x 26mm Itsm 16.8 kA VF(to) 0.91V Tj(max) 125°C rF 0.611mΩ Gate Terminals With 400mm Gate Leads R th(j-c) (double sided cooled 180°sin) 0.0184°C/W R th(c-h) (double sided cooled) 0.004°C/W Weight 600g Clamping Force 20 - 25kN Factory Pack Qty 6 Certification ROHS Dynex Headquarters UK Datasheet Product Datasheet Alternatives N1159NC400 Contact Us for Possible Replacement Dynex 2022 Shorform Catalogue Heatsink Heatsink Profiles
$969.00
$1,143.42 inclGST -
HS151DR Kit, Din Rail Mount Heatsink Kit for Single Phase Solid State Relay, 40Amp @ 40 Deg, Requires Assembly, 1.5°C/W
Crydom HS151DR Kit, Din Rail Mount Heatsink for Solid State Relays, 1.5°C/W Features DIN Rail or Panel Mount heat sink types Suitable for SSR Mounting Pre drilled for single or 3 phase SSR Black anodised for professional look Spec Crydom Part Number HS151DR Kit Mounting Type Din Rail Suitable SSR Rating 125 Amp Dimensions (without SSR) L:152.4mm x W:152.4mm x 88.9mm Thermal Impedance 1.5°C/W Load Current @ 40 Deg C 40 Amp Load Current @ 50 Deg C 35 Amp Unit Weight 437g Factory Pack Qty 10 Datasheet Product Datasheet App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$89.00
$105.02 inclGST