Search results for "텔레:bpmc55$"
-
93.34.61.200.0, Busbar Fixing KIT for LTC 600/1000
LEM 93.34.61.200.0 Busbar Fixing KIT for LTC 600/1000 (M5x25) Product Datasheet
$40.30
$47.55 inclGST -
GT-D-C-SP01, 0-60VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output
Fastron Electronics GTD-D-C-SP01, 0-60VDC Voltage Transducer/Transmitter, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GTD-D-C-SP01 Control Output 4-20mA Input 0 - 60VDC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22 - 60VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$219.00
$258.42 inclGST -
RCS-2400-2000 0.333V, 3 Phase 2000Amp AC Measurement 8 Inch Rogowski Coils with Integrator, Class 1
RCS-2400-2000 Three-Phase Flexible Current Sensor System(Rogowski Coils): The RCS-2400 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt. A 9 to 36 VDC power supply is required to operate these coils. The RCS-2400 comes with an integrator which includes flexible strain relief cables. Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads. Magnelab Coils come with 10 year warranty Suitable Alternative to Solar Edge CTRC-07500-2000 Specification Magnelab Part Number RCS-2400-2000 Function AC Current Measurement Nominal Measurement Current (Ipn) 2000 Amp RMS Measurement Range 10% - 130% if Ipn Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 9 - 36VDC Accuracy 1% from 25 to 2000 Amp Phase Angle < 0.5 Degrees Coil Diameter (⌀) 8 Inch Coil Circumference 24 Inch Integrator to Coil Cable 8 Feet Shielded Maximum Voltage 600V (on bare conductor) Operating Temperature -15°C to 65°C Storage Temperature -45°C to 80°C Power Consumption < 2VA Overload 20,000 Amp (continuous) Termination Style Screw Weight 1200g Certification CE Factory Pack Qty 1 Certifications UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1 Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010 CE ROHS Datasheet Product Datasheet Application Notes RCS/RCT Series Installation Guide
$930.00
$1,097.40 inclGST -
Burst Fire Controller, F431 Series 3 Phase, 380-440VAC, Cards Only
Oztherm F431 Series 3 Phase SCR Burst Controller Spare Card Set 100% Australian Made 3 Phase Burst Controller 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Burst Fired switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces Secondary or Direct Control only Controlled Power Applications Electric Boilers Smelting of Raw Metals Suitable for extreme environments such as mining Room/Chamber heating Available Options Current Limit and Trip AC (C) Power Limit (PW) Phase Loss Output (PH) Partial Load Failure (PLF) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F431 Series 3 Phase Burst Controller (Cards Only) Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current 30 - 120Amps Per Phase Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC, Power Limit, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 3kg Factory Pack Qty 1 Datasheet F431 Brochure F431 Installation and Commissioning Manual
$1,113.00 - $1,724.00
-
2 Leg Burst Fire Controller, F430 Series, 380-440VAC, Cards Only
Oztherm F430 Series 2 Leg SCR Burst Controller Spare Card Set 100% Australian Made 3 Phase Burst Controller 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Burst Fired switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces Secondary or Direct Control only Controlled Power Applications Electric Boilers Smelting of Raw Metals Suitable for extreme environments such as mining Room/Chamber heating Available Options Current Limit and Trip AC (C) Phase Loss Output (PH) Partial Load Failure (PLF) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F430 Series 2 Leg Burst Controller (Cards Only) Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current 30 - 120Amps Per Phase Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 3kg Factory Pack Qty 1 Datasheet F430 Brochure F430 Installation and Commissioning Manual
$1,063.00 - $1,459.00
-
V275K10, Varistor, 275VAC, 350VDC, K10 Axial Package 50W, Lugged
Varsi V275K10 Series Metal Oxide Varistor (MOV), 275VAC, 350VDC, K10 Axial Package 50W, Lugged High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Varsi Part Number V275K10 Operating Voltage AC (50-60Hz) 275V Operating Voltage DC 350V Average Power Dissipation 0.6W Permissable Peak Current 5.5kA Energy Absorption(2ms) 30W(max) Tolerance(Vn) +/- 10% Termination Style Ring Lug Weight 7g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article
$0.65
$0.77 inclGST -
MYG20-751, Varistor, 460VAC,615VDC, K20 Package, Lugged
Trent MYG20-751 Series Metal Oxide Varistor (MOV), 460VAC,615VDC, K20 Package, Lugged High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Trent Part Number MYG20-751 Operating Voltage AC (50-60Hz) 460V Operating Voltage DC 615V Average Power Dissipation 1W Permissable Peak Current 10kA Energy Absorption(2ms) 188W(max) Tolerance(Vn) +/- 10% Termination Style Ring Lug Weight 3g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article
$3.10
$3.66 inclGST -
MYG20-241, Varistor, 200VAC, 240VDC, K20 Axial Package 60W, Lugged
Trent MYG20-241 Series Metal Oxide Varistor (MOV), Varistor, 200VAC, 240VDC, K20 Axial Package 60W, Lugged High Energy Absorption Rating Industry Standard Package Wide Operating Range 35 - 1100VAC High Peak Current Capability (70kA) UL/CSA/ROHS/ISO9001:2015 Approved Panel Mount Screw Terminals APPLICATION AREAS: 1. Railways and trams: For the protection of electrical equipment, power electronics (IGBT, thyristors...) in systems with alternating, direct or combined AC + DC power supply, especially in power supply of AC/DC, DC/AC, DC/DC converters. They may be used in systems with main and auxiliary power supply for example: automatic control and regulation systems, cooling systems, warming systems, ventilation systems, and combination systems (electromechanical, electropneumatic and other systems). 2. Wind powerplants For protection of automatic control and regulation in power electronics (IGTB, tyristors...), as well as the protection of sensitive electronic systems (e. g. AC/DC, DC/AC, DC/DC converters, drive systems) from direct or indirect lightning strikes. 3. Photovoltaic systems For protection of photopanels, automatic control electronics with sensitive electronic components, and DC/AC converters (inverters) from direct or indirect lightning strikes. Depending on the application, both serial and parallel connections are possible. With serial connection the required voltage is achieved. With parallel connection higher current absorption is achieved in the modules. Specification Trent Part Number MYG20-241 Operating Voltage AC (50-60Hz) 200V Operating Voltage DC 240V Average Power Dissipation 1W Permissable Peak Current 10kA Energy Absorption(2ms) 127W(max) Tolerance(Vn) +/- 10% Termination Style Axial Lead Weight 3g Factory Pack Qty 1 ROHS Yes UL Yes CSA Yes Datasheet Product Datasheet Application Notes Technical Blog MOV Article
$3.10
$3.66 inclGST -
Phase Angle Controller, F330 Series 3 Phase, Cards Only
Oztherm F330 Series 3 Phase SCR Phase Angle Controller Spare Card Set, Can Replace Novatherm C3000 & C3000A Features 100% Australian Made 3 Phase, Phase Angle Controller or DC Soft Starter 4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control Fully enclosed IP20 Phase angle switching Aluminium Frame Removable perspex Cover Applications Electrical Ovens, Kilns, or Furnaces AC Soft Starter Controlled Power Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Sheet Metal Welding Available Options Voltage Regulation AC (A) Current Limit and Trip AC (C) Current Limit and Trip DC (CE) Current Control/Constant Current AC(CC) Current Control/Constant Current DC(CCE) Power Limit (PW) Phase Loss Alarm/Dispable (PH) Loose Semiconductor Fuses (F) Internal Semiconductor Fuses (FI) Thermal Overlad Protection (T) Special Features Contact Us for Possible Replacement for customised features Specification Oztherm Part Number F330 Series 3 Phase, Phase Angle Controller Rated Operationg Temperature 50°C SCR Configuration 3 Phase AC Swtich Control Voltage 4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration) Load Current N/A Control Range 0-100% Special Feature (Optional) Current Limit & Trip AC or DC, Current Control AC or DC, Voltage Regulation AC, Power Limit, Phase Loss Alarm, Thermal Overload Protection, Fuses Mounting Style Panel Mount Supply Voltage Range 380-440VAC +/-10% Soft Start 1-20mS Termination Style Screw Unit Weight up to 10kg Factory Pack Qty 1 Brochure F330 Brochure Technical Docs Installation and Commissioning Manual Standard Thyristor Wiring Diagram Control Card Wiring Diagram F311A1 New CCE option PCB1019-XX Wiring Diagram Bridge Output Thyristor Wiring Diagram Primary Transformer Wiring Diagram Start Delta Wiring Diagram Calibration Procedure Blog PDF Copy of Calibration Procedure Customised models Customised models list Contact Us for Possible Replacement for customised features not listed
$1,168.00 - $14,170.00
-
D5252505TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 25.0 KVAR, 525V, 50HZ, 120 x 230mm
D5252505TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 25.0 KVAR, 525V, 50HZ, 120 x 230mm Characteristics and utility 25 kVar @ 525V @ 50 Hz 25.0kvar 25kvar Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting True triple safety Overpressure disconnection system Protection by internal fuses DWCAP system (patented) internal windings Displacement Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification RTR Energia Part Number D5252505TER0000 Technology Dry Type, Low Loss, Self Healing Dimensions 120 x 230mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 25.0 Kvar Capacitance 3 x 96.24uF Tolerance On Capacitance -5% + 10% Current (In) 27.49 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES DWCAP system (Patented) internal windings Displacement YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 3.1kg Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables
$189.00
$223.02 inclGST -
D5254005TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 40.0 KVAR, 525V, 50HZ, 136 x 230mm
D5254005TER0000 Power Factor Correction Capacitor, 3 Phase, Dry Type DWCAP 40.0 KVAR, 525V, 50HZ, 136 x 230mm Characteristics and utility 40kVar @ 525V @ 50 Hz / 25kVar @ 400VAC Three phase capacitor DUAL WINDING internally delta connected Discharge resistors Incorporated Reactive power factor correction Dry type Connector type - single sided terminal Indoor mounting True Triple safety Overpressure disconnection system Protection by internal fuses DWCAP system (patented) internal windings Displacement Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR Energía Aluminium case with bottom fixing M12x16 Standards IEC 60831-1/2 EN 60831-1/2 Specification RTR Energia Part Number D5254005TER0000 Technology Dry Type, Low Loss, Self Healing Dimensions 136 x 230mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 525V @ 50Hz Kvar 40.0 Kvar Capacitance Tolerance On Capacitance -5% + 10% Current 44 Amp Overpressure Disconnection System YES Self Extinguishing Resin YES Internal Fuses YES DWCAP system (Patented) internal windings Displacement YES Mounting M12 x 16mm (Indoor) Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 120,000 Hours Termination Style Filter Type Terminal Unit Weight 4.9kg Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog Voltage Derating Tables
$229.00
$270.22 inclGST -
AHR 1000 B420, Hall Effect Current Sensor, 1000Amp, True RMS 4-20mA output, 104 x 40mm aperture
LEM AHR 1000 B420, Hall Effect Current Sensor, 1000Amp, True RMS 4-20mA output, 104 x 40mm aperture Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz Features Split Core VFD and SCR waveforms current measurement True RMS output 4-20mA current output Busbar mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable or busbar up to 104 x 40mm High isolation between primary and secondary circuits Easy installation Applications -AC Power Supplies or Motors True RMS sensing - the most accurate way to monitor power supply or input power -VFD Controlled Loads VFD output indicates how the motor and attached load are operating -SCR Controlled Loads Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement. -Renewable Energy Installations or Backup Batteries Continuous condition monitoring allowing automatic failure detection and prediction -Application Domain Energy and Automation Specification LEM Part Number AHR 1000 B420 Technology Open Loop Hall Effect ROHS Yes Supply Voltage 20 - 50V Nominal Current (RMS + DC) 1000 Amp Maximum Measurement Current (Peak) 2000 Amp Output 4-10mA Isolation 5.8kV (AC, 50Hz, 1 min) Bandwidth 20-6000Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style SFKC 2.5/4-ST-5.08-RF(Phoenix Contact) Unit Weight 650g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$735.00
$867.30 inclGST